background image

03

CONFIGURATION

▷ TRANSMITTERS CONFIGURATION

▷ FEATURES

FEATURES ◁

INSTALLATION PROCESS ◁

03

.

 CONFIGURATION

03.A

03.B

 

▷ New transmitters configuration - 2 keys (DIP 2 ON)

1 ▷

 Press the 

P1

 button once and the 

LED CODE

 will light during 6sec.

2 ▷

 While the 

CODE LED

 is light up, press the opening desired transmiter key during 

1sec and 

CODE LED

 will blink twice.

3 ▷

 The 

CODE LED

 will be light up again and you must now press the transmitter key 

for closing during 1 sec and 

CODE LED

 will blink twice.

4 ▷

 Let the 

CODE LED 

go off and the transmitter is now configured.

 

▷ New transmitters configuration - 1 key (DIP 2 OFF)

1 ▷

 Press the 

P1

 button once and the 

LED CODE

 will light up during 6sec.

2 ▷

 While the 

CODE LED

 is light up, press the desired transmiter key during 1sec and 

CODE LED

 will blink twice.

3 ▷

 Let the 

CODE LED 

go off and the transmitter is now configured.

NOTE: 

 After you program the first transmitter, the control board will only accept new 

transmitters of the same type. For example, if the first programmed transmitter is set 

for rolling code, the central will only accept more rolling code transmitters until a 

maximum of 46 transmitters.

 

▷ Programming remote controls without access to the control 

board 

• Using an already configured TRANSMITTER:

1 ▷

 Press transmitter’s 1 and 2 keys simultaneously for 3sec.

2 ▷

 Press the new transmitter’s desired opening key for 1sec. 

3 ▷

 Wait 3sec and press the desired closure key for 1sec.

4 ▷

 Wait 6sec and can now use the new device.

• Using one PUSH-BUTTON connected to the control board:

1 ▷

 Press for 2 seconds simultaneously the opening and closing buttons.

2 ▷

 Press the new transmitter’s desired opening key for 1sec. 

3 ▷

 Wait 3sec and press the desired closure key for 1sec.

4 ▷

 Wait 6sec and can now use the new device.

 

▷ Erase all configured transmitters

1 ▷

 Press and hold the 

P1 key 

for 10sec. The 

CODE LED

 will remain light up the entire 

time and will start to blink at the end of 10sec.

2 ▷ 

Release the 

P1 key

 and 

LED CODE

 will stop flashing and remain lit for 3sec so that 

you configure a new transmitter (note the DIP2 position).

3 ▷

 If you do not want to configure new transmitter, let the 

CODE LED 

go off without 

pressing any key.

 

▷ Adjusting the Working Time and the Pause Time

The

 Working Time

 can be set to 60sec ,90sec and 120sec .

To set any of these values, press the

 P2

 button as many times as needed until the 

desired option is defined 

while the engine is running

.

▷ For each pulse in the 

P2 

button with the motor running, the 

CODE LED

 will flash 

once for 60sec, twice for 90sec and thrice to 120sec.

The

 Pause Time 

can be set to 30sec, 60sec and 90sec.

To set any of these values, press the

 P2 

button repeatedly until the desired option is 

defined 

while the engine is paused 

(must enable auto-locking by putting DIP1-ON)

.

▷ For each pulse in the 

P2 

button with the motor opened in pause time, the 

CODE LED

 

will flash one time for 30sec, two times for 60sec and three times to 90sec.

NOTE:

   ▷ The 

Working Time

 should be set to a value above the actual required working time. 

For example, if the automatism needs 40sec to go all the course, you must set the 

Working Time

 for 60sec.

 

▷ Setting the motor working direction 

To verify that the operating direction is correct, proceed as follows:

1 ▷

 With a configured transmitter give order with the key that you have programmed in 

the first place and the automatism must begin to open. If it starts to close, swap the 

motor wires at terminals 4 and 5 from the CN1 connector.

 

▷ Safety photocells (NC)

1 ▷

 To enable the use of photocells, place the Dipper 4 to 

OFF

.

Safety photocells act as follows:

▷ In opening maneuvers, has no action.

▷ When opened, the photocells cause the gate to remain open if there is an obstacle in 

front of them.

▷ In closing maneuvers, the gate stops and starts to open immediately, stopping at the 

end of the working time or at the end of the opening limit-switch.

1 ▷

 Connect the control board to a 230V power supply (terminals 1 and 2 - CN1).

2 ▷

 Configure the Dippers according to the used devices and the desired type of 

operation.

3 ▷

 Configure transmitter.

NOTE:

 Be aware of any component connected to the control board as the motor or 

photocells.

This control board can operate all types of motor which doesn’t exceed 1500W of 

power and photocells which doesn’t exceed a consumption over 80mA.

Содержание MC101

Страница 1: ...ifications page 01 B dippers function page 01 B connectors page 02 A 03 CONFIGURATION transmmiter s configuration page 02 B functionalities page 03 A instalation process page 03 B 04 DIAGNOSIS failures diagnosis page 04 A motor diagnosis page 04 A 05 CONNECTION SCHEME component connection to the control board page 04 B v1 0 REV 05 2014 1 ON 2 3 4 ...

Страница 2: ...ust inform the client how to handle the product in case of emergency and provide this manual to user Keep remote controls away from children to prevent the automated system from being activated involuntarily The customer shall not under any circumstances attempt to repair or tune the automatism Must call qualified technician only Connect the automatism to a 230Vplug with ground wire Control board ...

Страница 3: ...g to the control board configuration please note the following points listed in the table below in order to better understand the control board function Button 1 Button 2 Button 3 Button 4 MX4SP Button 1 Button 2 Button 3 Button 4 MXS4SP New transmitters configuration 2 keys DIP 2 ON 1 Press the P1 button once and the LED CODE will light during 6sec 2 While the CODE LED is light up press the openi...

Страница 4: ...must enable auto locking by putting DIP1 ON For each pulse in the P2 button with the motor opened in pause time the CODE LED will flash one time for 30sec two times for 60sec and three times to 90sec NOTE The Working Time should be set to a value above the actual required working time For example if the automatism needs 40sec to go all the course you must set the Working Time for 60sec Setting the...

Страница 5: ... in the control board If the engine is running connected to a power source it means that the problem is in another component such as control board or power supplies All tests must be performed by professional technicians due to serious danger associated with the misuse of electrical systems To detect which components have problems in an installa tion it is sometimes necessary to perform a test wit...

Отзывы: