![Motrec E-242HD Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/motrec/e-242hd/e-242hd_operator-and-maintenance-manual_1839494025.webp)
Curtis 1243
GEN
2 Manual
72
7 — DIAGNOSTICS & TROUBLESHOOTING
Table 7
TROUBLESHOOTING CHART
LED
PROGRAMMER
FAULT
CODE
LCD DISPLAY
CATEGORY
POSSIBLE CAUSE
FAULT CLEARANCE
0,1
NO KNOWN FAULTS
0
n/a
n/a
1,1
CURRENT SHUNT FAULT
1
1. Abnormal vehicle operation causing
Cycle KSI. If problem
high current spikes.
persists, replace controller.
2. Current sensor out of range.
3. Controller failure.
1,2
HW FAILSAFE
1
1. Noisy environment.
Cycle KSI. If problem
2. Self-test or watchdog fault.
persists, replace controller.
3. Controller failure.
1,3
M- SHORTED
1
1. Internal or external short of M- to B-.
Check wiring; cycle KSI.
2. Incorrect motor wiring.
If problem persists,
3. Controller failure.
replace controller.
1,4
SRO
3
1. Improper sequence of KSI, interlock,
Follow proper sequence;
and direction inputs.
adjust throttle if necessary;
2. Interlock or direction switch circuit open.
adjust programmable
3. Sequencing delay too short.
parameters if necessary.
4. Wrong SRO or throttle type selected.
5. Misadjusted throttle pot.
2,1
THROTTLE WIPER HI
1
1. Throttle input wire open or shorted to B+. When Throttle Wiper High
2. Defective throttle pot.
input returns to valid range.
3. Wrong throttle type selected.
2,2
EMR REV WIRING
1
1. Emergency reverse wire or check wire
Re-apply emergency reverse
open.
or cycle interlock.
2,3
HPD
3
1. Improper sequence of KSI, interlock,
Follow proper sequence;
and throttle inputs.
adjust throttle if necessary;
2. Misadjusted throttle pot.
adjust programmable
3. Sequencing delay too short.
parameters if necessary.
3. Wrong HPD or throttle type selected.
5. Misadjusted throttle pot.
SRVC TOTAL
3
1. Total maintenance timer expired.
Reset with programmer.
SRVC TRAC
3
1. Traction maintenance timer expired.
Reset with programmer.
TOTAL DISABLED
3
1. Total disable timer expired.
Reset with programmer.
TRAC DISABLED
3
1. Traction disable timer expired.
Reset with programmer.
2,4
THROTTLE WIPER LO
1
1. Throttle pot wire open or shorted to B+.
When Throttle Wiper Low
2. Wrong throttle type selected.
input returns to valid range.
3. Defective throttle pot.
3,1
FIELD SHORT
1
1. Main contactor coil shorted.
Check contactor coil and
2. Field winding shorted to B+ or B-.
field winding; cycle KSI.
3. Field resistance too low.
3,2
MAIN CONT WELDED
1
1. Main contactor stuck closed.
Check wiring and contactor;
2. Main contactor driver shorted.
cycle KSI.
3,3
FIELD OPEN
1
1. Field winding connection open.
Check wiring and cycle KSI.
2. Field winding open.
3,4
MISSING CONTACTOR
1
1. Main contactor coil open.
Check wiring and cycle KSI.
2. Main contactor missing.
3. Wire to main contactor open.
- 25 -
Содержание E-242HD
Страница 4: ...Instructions 4 INSTRUCTIONS...
Страница 7: ...Maintenance 7 MAINTENANCE...
Страница 21: ...Curtis Speed Controller 21 CURTIS SPEED CONTROLLER...
Страница 29: ...Curtis Speed Controller 29 CURTIS PMC MOTOR CONTROLLER...
Страница 35: ...Spare Parts 35 SPARE PARTS...
Страница 37: ...Spare Parts 37 DIFFERENTIAL...
Страница 45: ...Spare Parts 45 ELECTRICAL DIAGRAM SEPEX MAIN CIRCUIT DIAGRAMME LECTRIQUE CIRCUIT PRINCIPAL SEPEX...
Страница 46: ...Spare Parts 46 ELECTRICAL DIAGRAM SERIES MAIN CIRCUIT DIAGRAMME LECTRIQUE CIRCUIT PRINCIPAL S RIES...
Страница 47: ...Spare Parts 47 ACCESSORIES NO DC DC CONVERTER ACCESSOIRES SANS CONVERTISSEUR DC DC...
Страница 49: ...Spare Parts 49 BATTERY CONFIGURATIONS 24V CONFIGURATIONS DES BATTERIES 24V...
Страница 55: ...Spare Parts 55...
Страница 56: ...Spare Parts 56...