SETTING UP
After laying and connecting all the cables mentioned above, have skilled staff commission the operator by
fi
rst running the
following functions:
- type of motor (A1);
- number of motors (F46);
- motors test (A2)
Self-learning of the gate travel (A3).
Motor type
The control board is not con
fi
gured to control the gearmotors. You will need to con
fi
gure it by setting function A1 as follows:
Select F46.
Press ENTER to con
fi
rm.
Select 1 and press ENTER to con
fi
rm the con
fi
guration for just
one gearmotor.
Number of motors
The control board is con
fi
gured to control two gearmotors. To control just one gearmotor, set function F46 as follows:
Select A1.
Press ENTER to con
fi
rm.
Select 5 and press ENTER to con
fi
rm the con
fi
guration.