- Size 2 Fan Kit Installation Guide 

               

           2 | 

P a g e

 

 

Fan (VMX-AGY-031) 

 

VMX-AGY-031 is designed for models VMX-AGY-201 to VMX-AGY-209. It increases the number of start/stop cycles 
per hour (see table below). The fan operates automatically during a soft start or soft stop and will continue to run if 
the heatsink temperature is > 113

 o

F (45

o

C). The fan stops when the heatsink temperature has fallen below 104

 o

(40

o

C). 

 

Fitting 

 

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 

 

 

 
 

 
 

 

 
 
 
 
California Customers:  
 
California Proposition 65 Warning 

WARNING: this product and associated accessories may contain chemicals known to the State of California to cause cancer, birt h 
defects, or other reproductive harm. For more information visit 

https://p65warnings.ca.gov

 

 

Agility model 

Maximum duty cycle F-S with optional fan fitted 

VMX-AGY-201 / VMX-AGY-203 

90-40 (40 cycles per hour) 

VMX-AGY-205 

90-30 (30 cycles per hour) 

VMX-AGY-207 

90-20 (20 cycles per hour) 

VMX-AGY-209 

90-10 (10 cycles per hour) 

Step 2. Loosen the two lower mounting screws (2a) and 
slide the fan assembly downward between the mounting 
bracket and the heatsink fins (2b) 

Step 1. Position the assembly at the top on the 
VMX-agility unit 

Step 4. Remove the blanking plug and insert the flying lead 
from the fan assembly into the socket as indicated below.    

2a 

Step 3. When the fan assembly is fully inserted and the 
lower plate of the assembly has engaged with the lower 
mounting screws, re-tighten the mounting screws fully.   

2b 