Fan (VMX-AGY-031)
VMX-AGY-031 is designed for models VMX-AGY-201 to VMX-AGY-209. It increases the number of start/stop cycles
per hour (see table below). The fan operates automatically during a soft start or soft stop and will continue to run if
the heatsink temperature is > 113
o
F (45
o
C). The fan stops when the heatsink temperature has fallen below 104
o
F
(40
o
C).
Fitting
California Customers:
California Proposition 65 Warning
WARNING: this product and associated accessories may contain chemicals known to the State of California to cause cancer, birt h
defects, or other reproductive harm. For more information visit
Agility model
Maximum duty cycle F-S with optional fan fitted
VMX-AGY-201 / VMX-AGY-203
90-40 (40 cycles per hour)
VMX-AGY-205
90-30 (30 cycles per hour)
VMX-AGY-207
90-20 (20 cycles per hour)
VMX-AGY-209
90-10 (10 cycles per hour)
Step 2. Loosen the two lower mounting screws (2a) and
slide the fan assembly downward between the mounting
bracket and the heatsink fins (2b)
Step 1. Position the assembly at the top on the
VMX-agility unit
Step 4. Remove the blanking plug and insert the flying lead
from the fan assembly into the socket as indicated below.
2a
Step 3. When the fan assembly is fully inserted and the
lower plate of the assembly has engaged with the lower
mounting screws, re-tighten the mounting screws fully.
2b