background image

 

Installation Requirements 

The Mesh Serial Modem will require the following in a typical installation: 

  5 – 14.0 VDC Power. 

  A suitable mounting location 

  Antenna and RF cabling appropriate for use in the 2.4 GHz band.  

WSM6300 Assembly 

The external connection points on a WSM6300 unit are shown below. 

  The power / serial connector interface is shown on the upper left corner below. 

  The antenna port (N-type male) is shown on the upper right corner below. 

  The transceiver MAC address is recorded on the label located on front side of the WSM 

unit.  Record the MAC Address in the table in the WSM6300 MAC Addresses section of 
this document.  

 

 

Figure 1. 

WSM6300 Assembly 

 

 

 

 

2

Содержание WSM6300

Страница 1: ...MEA 3 1 WSM6300 Wireless Serial Modem Users Guide Documentation Revision 3 1 5 ...

Страница 2: ......

Страница 3: ...lusive royalty free license to use that arises by operation of law in the sale of a product Disclaimer Please note that certain features facilities and capabilities described in this document may not be applicable to or licensed for use on a particular system or may be dependent upon the characteristics of a particular mobile subscriber unit or configuration of certain parameters Please refer to y...

Страница 4: ...ressing 6 WSM6300 MAC Addresses Table 6 Configurable Parameters 7 CUSTOMER SERVICE INFORMATION 9 Obtaining Support 10 System Information 10 Return Material Request 10 Radio Products and Services Division 10 Radio Products and Services Division Telephone Numbers 11 Returning System Components to Motorola 11 Returning FREs 11 PRODUCT WARRANTY INFORMATION 12 FCC REGULATORY INFORMATION 15 FCC Informat...

Страница 5: ...MEA WSM6300 Users Guide FCC RF Energy Exposure Statement 15 Regulatory and RF Safety Exposure 15 iii ...

Страница 6: ...List of Figures Figure 1 WSM6300 Assembly 2 Figure 2 WSM Serial Cable 3 Figure 3 Device Manager Wireless Router Configuration Panel 7 iv ...

Страница 7: ... WSM6300 efficiently combines the functionality of a MEA infrastructure device and sensor interface into a single cost effective wireless network component This makes it easy to attach a remote sensor device to a Mesh Enabled Architecture MEA mobile broadband network Sensors controllers signs signals etc can all be Mesh Enabled to send and receive data via the MEA network Each WSM6300 can be indiv...

Страница 8: ...bly The external connection points on a WSM6300 unit are shown below The power serial connector interface is shown on the upper left corner below The antenna port N type male is shown on the upper right corner below The transceiver MAC address is recorded on the label located on front side of the WSM unit Record the MAC Address in the table in the WSM6300 MAC Addresses section of this document Fig...

Страница 9: ...ING The WSM6300 chassis must be grounded to prevent the possibility of damage induced by Electro Static Discharge ESD 2 Connect the antenna or antenna cable to the to the N type antenna port 3 Insert the Power Plug Serial connector into 6 pin connector port Figure 2 WSM Serial Cable Pin Number Signal Power Serial Cable Color 1 PWR GND Black 2 5 14 0 VDC Red 3 GPIO5 0 to 3 3 V Blue 4 TX RS 232 or A...

Страница 10: ...le section of this document The address will be in the format 00 05 12 0A xx yy for the Transceiver MAC address 3 From MeshManager display devices using the MAC address 4 Select the appropriate WSM in the device tree and then ping the device right click and select ping A successful response to the ping command verifies that the WSM is communicating to the infrastructure devices A WSM6300 is compat...

Страница 11: ...MEA WSM6300 Users Guide Optional Equipment Antenna Cable as required Antenna cable adapter as required 5 ...

Страница 12: ... the Mesh Sensor Network Configuration Guide and the MeshManager Users Guide for more detailed information on the MiSC DHCP server configuring and using the CyberGuard network appliance and network configuration and monitoring using MeshManager WSM6300 MAC Addresses Table This table has been included for recording the Transceiver MAC Address for a set of WSM6300 devices as a quick reference These ...

Страница 13: ...and configuration of MEA network devices Figure 3 Device Manager Wireless Router Configuration Panel Parameter Description Baud Rate The transmission speed in bits per second at which data is sent and received asynchronously at the serial port The baud rate is generally determined by the requirements of the attached sensor Supported baud rates are 300 600 1200 2400 4800 9600 14 400 19 200 38 400 5...

Страница 14: ...mission at this periodic interval Sync Character Data is packetized for transmission when this ASCII character is received from the serial interface Bytes Collected Data is packetized for transmission when this number of bytes is collected in the serial interface receive buffer Transmit IP Address IP Address that a sensor to will send its data to This address can be on the same host that executes ...

Страница 15: ...em Support Center SSC using the following contact information Phone 800 221 7144 Hours of Operation 7 days a week 24 hours Europe Phone 44 0 1793 564680 Email essc motorola com Hours of Operation Mon Fri 09 00 17 00 GMT Calls are logged 24 x 7 cases will be worked Mon Fri 09 00 17 00 GMT Asia and Pacific Region Remote Technical Help Desk Channel Partners Phone 63 28 92 79 93 Email wi4Tech motorola...

Страница 16: ... your system Serial number s of the device s or component s requiring support A written description of the symptom or observation of the problem When did it first appear Can it be reproduced What is the step by step procedure to cause it Do other circumstances contribute to the problem For example changes in weather or other conditions Maintenance action preceding problem Upgrade of software or eq...

Страница 17: ...repair Returning FREs Return faulty FREs to Motorola for repair When you return an assembly for service follow these best practices Place any assembly containing CMOS devices in a static proof bag or container for shipment Obtain a return authorization RA number from the Motorola System Support Center Include the warranty model kit numbers and serial numbers on the job ticket as necessary If the w...

Страница 18: ...ty This is the complete warranty for the Product manufactured by Motorola Motorola assumes no obligations or liability for additions or modifications to this warranty unless made in writing and signed by an officer of Motorola Unless made in a separate written agreement between Motorola and the original end user purchaser Motorola does not warrant the installation maintenance or service of the Pro...

Страница 19: ...e purchaser s requirements or that the operation of the software will be uninterrupted or error free L Normal and customary wear and tear M Non Motorola manufactured equipment unless bearing a Motorola Part Number in the form of an alpha numeric number i e TDE6030B N Lift trucks for installation removal replacement or repair of the Motorola supplied products from light power telephone poles etc O ...

Страница 20: ... patents by the Product or any its parts thereof Laws in the United States and other countries preserve for Motorola certain exclusive rights for copyrighted Motorola software such as the exclusive rights to reproduce in copies and distribute copies of such Motorola software Motorola software may be used in only the Product in which the software was originally embodied and such software in such Pr...

Страница 21: ...e the receiving antenna Increase the separation between the WMC6300 and radio or television receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the supplier of the WMC6300 or an experienced radio TV technician for help FCC RF Energy Exposure Statement 5 This equipment complies with FCC RF Energy exposure limits set forth for an ...

Страница 22: ...9 KHz and 300 GHz and Attachment to resolution 303 from July 2 2002 RF Exposure Compliance and Guidelines Operating Instructions To ensure compliance with the general population uncontrolled environment RF exposure limits in these standards the antenna should be kept at a minimum separation distance of 20cm from all persons when used in a personal or laptop computer ATTENTION To ensure compliance ...