background image

859.0088

23

Operating Temperature Range

* The maximum temperature listed is based on the ATEX standard for T4 temperature classification. If you are
operating in a non-explosive environment, FKM fluoroelastomer’s maximum operating temperature in aluminum or 
stainless steel pumps is 320°F (160°C).

NOTICE

Temperature limits are based on mechanical stress only. Certain chemicals will further limit the 
fluid temperature range. Stay within the temperature range of the most-restricted wetted compo-
nent. Operating at a fluid temperature that is too high or too low for the components of your pump 
may cause equipment damage.

Diaphragm/Ball/Seat 
Material

Fluid Temperature Range

Aluminum or

Stainless Steel Pumps

Polypropylene or 

Conductive 

Polypropylene Pumps

PVDF Pumps

Fahrenheit

Celsius

Fahrenheit

Celsius

Fahrenheit

Celsius

Acetal (

AC

)

10° to 180°F

-12° to 82°C

32° to 150°F 0° to 66°C

10° to 180°F

-12° to 82°C

Buna-N (

BN

)

10° to 180°F

-12° to 82°C

32° to 150°F 0° to 66°C

10° to 180°F

-12° to 82°C

FKM Fluoroelastomer 
(

FK

)*

-40° to 275°F -40° to 135°C 32° to 150°F 0° to 66°C

10° to 225°F -12° to 107°C

Geolast

®

 (

GE

)

-40° to 150°F

-40° to 66°C

32° to 150°F 0° to 66°C

10° to 150°F

-12° to 66°C

Neoprene overmolded 

diaphragm (

CO

) or 

Neoprene check balls 
(

CR

 or 

CW

)

0° to 180°F

-18° to 82°C

32° to 150°F 0° to 66°C

10° to 180°F

-12° to 82°C

Polypropylene (

PP

)

32° to 150°F

0° to 66°C

32° to 150°F 0° to 66°C

32° to 150°F

0° to 66°C

PTFE overmolded

diaphragm (

PO

)

40° to 180°F

4° to 82°C

40° to 150°F 4° to 66°C

40° to 180°F

4.0° to 82°C

PTFE check balls or 
two-piece PTFE/EPDM 
diaphragm (

PT

40° to 220°F

4° to 104°C

40° to 150°F 4° to 66°C

40° to 220°F

4° to 104°C

PVDF (

PV

)

10° to 225°F -12° to 107°C 32° to 150°F 0° to 66°C

10° to 225°F -12° to 107°C

Santoprene

®

 (

SP

)

-40° to 180°F

-40° to 82°C

32° to 150°F 0° to 66°C

10° to 180°F

-12° to 82°C

TPE (

TP

)

-20° to 150°F

-29° to 66°C

32° to 150°F 0° to 66°C

10° to 150°F

-12° to 66°C

Содержание Verizon moto g6

Страница 1: ...ing approvals 125 psi 0 86 MPa 8 6 bar Maximum Fluid Working Pressure 125 psi 0 86 MPa 8 6 bar Maximum Air Input Pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions VA25A Aluminum ti13946a ti14342a VA25S Stainless Steel Center Flange ti13844a ti13843a End Flange VA25P Polypropylene VA25C Conductive Polypropylene VA25F PVDF Patents Pendin...

Страница 2: ... Before Setup 14 Starting and Adjusting the Pump 14 Pump Shutdown 15 Maintenance 15 Maintenance Schedule 15 Lubrication 15 Tighten Threaded Connections 15 Flushing and Storage 15 Torque Instructions 16 Dimensions and Mounting 17 Aluminum VA25A 17 Polypropylene VA25P Conductive Polypropylene VA25C and PVDF VA25F Center Flange 18 Polypropylene VA25P Conductive Polypropylene VA25C and PVDF VA25F End ...

Страница 3: ...folds VA25A Aluminum VA25C Conductive Polypropylene VA25F PVDF VA25P Polypropylene VA25S Stainless Steel Aluminum A01A Standard A1 A2 C1 C2 F1 F2 P1 P2 S1 S2 Aluminum standard ports inch Aluminum standard ports metric Conductive polypropylene center flange Conductive polypropylene end flange PVDF center flange PVDF end flange Polypropylene center flange Polypropylene end flange Stainless steel sta...

Страница 4: ...sion Use equipment only in well ventilated area Eliminate all ignition sources such as pilot lights cigarettes portable electric lamps and plastic drop cloths potential static arc Keep work area free of debris including solvent rags and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Ground all equipment in the work area See Gro...

Страница 5: ...ipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations PRESSURIZED EQUIPMENT HAZARD Fluid from the gun dispense valve leaks or ruptured c...

Страница 6: ...hich could cause serious injury or property damage See Technical Data in this and all other equipment instruction manuals Read fluid and solvent manufacturer s warnings TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read MSDS s to know the specific hazards of the fluids you are using Route exhaust away fro...

Страница 7: ...s available Air and fluid hoses Use only grounded hoses with a maximum of 500 ft 150 m combined hose length to ensure grounding continuity Air compressor Follow manufacturer s recommendations Fluid supply container Follow local code Solvent pails used when flushing Follow local code Use only conductive metal pails placed on a grounded surface Do not place the pail on a nonconductive surface such a...

Страница 8: ...r inlet D Use a minimum 3 8 in 10 mm ID air hose Reed Switch Pulse Count kits are available for use with cus tomer supplied fluid management or inventory tracking systems Attach an M12 5 pin female cable to connect the reed switch to your data monitoring system See Manual 859 0099 Air Exhaust Ventilation The air exhaust port is 3 4 npt f Do not restrict the air exhaust port Excessive exhaust restr...

Страница 9: ...iaphragm life will be shortened 4 For maximum suction lift wet and dry see Technical Data page 22 Fluid Outlet Line See FIG 3 and FIG 4 pages 10 and 11 1 Use grounded fluid hoses L See Ground ing page 7 2 Install a fluid drain valve J near the fluid outlet 3 Install a shutoff valve K in the fluid outlet line FIG 2 Vent exhaust air Key A Air supply line B Bleed type master air valve C Air regulator...

Страница 10: ...10 859 0088 FIG 3 Typical bung mount installation aluminum VA25A pump shown E F C B A K L J R H G D M N M ti14163a ...

Страница 11: ...Aluminum FIG 3 four ports one not visible Plastic FIG 4 center or end flanges available Stainless Steel not pictured one port N Fluid outlet Aluminum FIG 3 four ports one not visible Plastic FIG 4 center or end flanges available Stainless Steel not pictured one port R Ground wire required for aluminum conductive polypropylene and stainless steel pumps see page 7 for installation instructions FIG 4...

Страница 12: ... kits are available in poly propylene 819 6885 stainless steel 819 6886 and PVDF 819 6887 These kits include the pipe flange a PTFE gasket four 1 2 in bolts spring lock washers flat washers and nuts Be sure to lubricate the threads of the bolts and torque to 10 15 ft lb 14 20 N m Follow the bolt tightening sequence and do not over torque Stainless Steel VA25S The fluid inlet and outlet manifolds e...

Страница 13: ...r when pumping from a cool to a warm area for example from an underground tank Overpressurization also can occur if the pump is used to feed fluid to a piston pump and the intake valve of the piston pump does not close causing fluid to back up in the outlet line FIG 6 shows Fluid Pressure Relief Kit 819 6479 for aluminum pumps Use Fluid Pressure Relief Kit 819 0159 not shown for plastic pumps Appl...

Страница 14: ...r to Grounding on page 7 2 Check fittings to be sure they are tight Use a compatible liquid thread sealant on male threads Tighten fluid inlet and outlet fittings securely 3 Place the suction tube if used in fluid to be pumped NOTE If fluid inlet pressure to the pump is more than 25 of outlet working pressure the ball check valves will not close fast enough resulting in inefficient pump operation ...

Страница 15: ...nnections Before each use check all hoses for wear or damage and replace as necessary Check to be sure all threaded connections are tight and leak free Check fasteners Tighten or retorque as necessary Although pump use varies a general guideline is to retorque fasteners every two months See Torque Instructions page 16 Flushing and Storage Flush before fluid can dry in the equipment at the end of t...

Страница 16: ...hem using the following procedure to improve sealing NOTE Always completely torque fluid covers before torquing manifolds Start all fluid cover screws a few turns Then turn down each screw just until head contacts cover Then turn each screw by 1 2 turn or less working in a crisscross pattern to specified torque Repeat for manifolds Fluid cover and manifold fasteners 100 in lb 11 3 N m Retorque the...

Страница 17: ...127 mm ti14540b A 12 7 in 323 mm B 14 4 in 366 mm C 15 9 in 404 mm D 10 9 in 277 mm E 1 8 in 46 mm F 7 3 in 185 mm G 14 7 in 373 mm H 6 2 in 158 mm J 3 9 in 99 mm K 10 2 in 258 mm L 1 2 npt f air inlet M 1 in npt f or 1 in bspt fluid inlet ports 4 N 1 in npt f or 1 in bspt fluid outlet ports 4 P 3 4 npt f air exhaust port ...

Страница 18: ...5b ti13847b ti13846b LQ PP LQ PP ti14541b A 13 2 in 335 mm B 15 7 in 399 mm C 17 8 in 452 mm D 12 0 in 305 mm E 2 5 in 63 5 mm F 8 0 in 203 mm G 16 0 in 406 mm H 6 2 in 1158 mm J 3 9 in 99 mm K 10 2 in 258 mm L 1 2 npt f air inlet M 1 in ANSI DIN flange N 1 in ANSI DIN flange P 3 4 npt f air exhaust port ...

Страница 19: ...0a ti14823a ti14821a LQ PP LQ PP ti14822 A 13 2 in 335 mm B 15 7 in 399 mm C 17 8 in 452 mm D 12 0 in 305 mm E 2 5 in 63 5 mm F 8 0 in 203 mm G 15 2 in 386 mm H 6 2 in 158 mm J 3 9 in 99 mm K 10 2 in 258 mm L 1 2 npt f air inlet M 1 in ANSI DIN flange N 1 in ANSI DIN flange P 3 4 npt f air exhaust port ...

Страница 20: ...45b A 11 8 in 300 mm B 12 9 in 328 mm C 13 7 in 348 mm D 9 5 in 241 mm E 1 1 in 28 mm G 13 9 in 353 mm H 6 2 in 158 mm J 4 0 in 102 mm K 10 2 in 258 mm L 1 2 npt f air inlet M 1 in npt f or 1 in bspt fluid inlet ports 4 N 1 in npt f or 1 in bspt fluid outlet ports 4 P 3 4 npt f air exhaust port ...

Страница 21: ...hart or air consumption bottom chart 0 5 10 15 20 25 30 35 40 45 50 19 38 57 76 95 114 133 152 170 189 Fluid Flow gpm lpm 20 40 60 80 0 56 1 12 1 68 2 24 A B C D 0 0 20 40 60 80 100 120 0 14 1 4 0 28 2 8 0 41 4 1 0 55 5 5 0 7 7 0 0 83 8 3 Fluid Flow gpm lpm Air Consumption scfm cubic meters min Operating Air Pressure A 125 psi 0 83 MPa 8 3 bar B 100 psi 0 7 MPa 7 0 bar C 70 psi 0 48 MPa 4 8 bar D ...

Страница 22: ...l flow 84 dBa 96 dBa Operating temperature range see page 23 Air inlet size 1 2 npt f Fluid inlet size Aluminum VA25A Plastic VA25P VA25C and VA25F Stainless Steel VA25S 1 in npt f or 1 in bspt 1 in raised face ANSI DIN flange 1 in npt f or 1 in bspt Fluid outlet size Aluminum VA25A Plastic VA25P VA25C and VA25F Stainless Steel VA25S 1 in npt f or 1 in bspt 1 in raised face ANSI DIN flange 1 in np...

Страница 23: ...it Celsius Acetal AC 10 to 180 F 12 to 82 C 32 to 150 F 0 to 66 C 10 to 180 F 12 to 82 C Buna N BN 10 to 180 F 12 to 82 C 32 to 150 F 0 to 66 C 10 to 180 F 12 to 82 C FKM Fluoroelastomer FK 40 to 275 F 40 to 135 C 32 to 150 F 0 to 66 C 10 to 225 F 12 to 107 C Geolast GE 40 to 150 F 40 to 66 C 32 to 150 F 0 to 66 C 10 to 150 F 12 to 66 C Neoprene overmolded diaphragm CO or Neoprene check balls CR o...

Страница 24: ...etelményeit Atbilst EK direktīvām Atitinka šias ES direktyvas Zgodność z Dyrektywami UE Konformi mad Direttivi tal KE V skladu z direktivami ES Je v súlade so smernicami ES Съвместимост с Директиви на ЕО Tá ag teacht le Treoracha an CE Respectă directivele CE 2006 42 EC Machinery Safety Directive 94 9 EC ATEX Directive Ex II 2 GD c II C T4 Tech File stored with NB 0359 See Part No above for corres...

Страница 25: ...ice WARRANTY DISCLAIMER VERDER has made an effort to illustrate and describe the products in the enclosed brochure accurately however such illustrations and descriptions are for the sole purpose of identification and do not express or imply a warranty that the products are merchantable or fit for a particular purpose or that the products will necessarily conform to the illustration or descriptions...

Страница 26: ...info verder hu The Netherlands Van Wijk Boerma Pompen B V Leningradweg 5 NL 9723 TP Groningen THE NETHERLANDS Tel 31 50 549 59 00 Fax 31 50 549 59 01 e mail info wijkboerma nl Poland Verder Polska ul Ligonia 8 1 PL 40 036 Katowice POLAND Tel 48 32 78 15 032 Fax 48 32 78 15 034 e mail verder verder pl Romania Verder România Drumul Balta Doamnei no 57 61 Sector 3 CP 72 117 032624 Bucuresti ROMANIA T...