Topaz T2688/T200, T2988/T205 L3 Circuit Description
13
Motorola Proprietary Information
These are:
?
Power on generated by set alarm, which is generated from the RTC (the alarm
is set into the menu structure of the phone).
U54
Pin 2
?
IO2
, software originated power on from
Gemini
Pin 112
.
U54
Pin 1
?
From depressing the Power On key giving the signal
PWR
.
U53
Pin 2
?
From the External Charger (
CHGERP
).
U53
Pin 1
77.
As the unit begins to power up the reset signal is generated, again a +ve going signal.
Charging
C57
generates the charge for the reset signal.
78.
As for the GCAP the
Power Control IC
also interfaces with the SIM Card, VCC for
the SIM card is provided by
Pin 20
, onto SIM Block
Pins 4 & 5
. However the
occasional need for 5V SIM is provided using the input from the scaled
DVCC
on
Pin 17
and the charge pump
C53
Pins 21 & 9
.
79.
Data is read from the SIM card on
pin 2
of the SIM block I/O into
U27
Pin 15
(
IO
)
and transmitted to the
Gemini
from
U27
Pin 11
(
S-IO
). Also from
Gemini
are the
SIM CLK
U27
Pin 13
[
in
] &
Pin 19
[
out
] (
SIM Block
Pin 1
) and the SIM Reset
U27
Pin 12
[
in
] and
Pin 16
[
out
] (
SIM Block
Pin 3)
80.
SIM I/O
also ac ts as a SIM Presence detect signal.
81.
Power for the unit can be taken from either internal Battery or from an external
source. The battery has 4 contacts, from
battery connector JP2
?
Pin 1
Supplies
VBAT
directly
?
Pin 2
BATEMP
is used to monitor Battery temperature during charging, and is
fed to
VEGA
for A / D processing.
?
Pin 3
BAID
is Battery ID and is used for the detection of different types of
batteries.
?
Pin4
is ground
Alternatively the
VBAT
source can be taken from an external power source, this
originates at the
I/O connector U40
Pin A3
, with
U36
providing ESD protection, the
signal is then fed as
CHGERP
, and through
Fuse F1
. As mentioned in Point 76 this
will ensure the unit powers up but will also pass through
BQ3
and protection diode
D14
to provide
VBAT
.
D15
limits input voltage to <6V
82.
U30
is used to detect the charger and is supported by
DVCC
, once detected an
interrupt is sent to
Gemini
as
IO9
83.
For the Initial charge at low battery voltage, as before the input voltage at
CHGERP
is approximately 6V,
CHGERP
originates at
U40
Pin T3
with
T1
as its respective
Ground
84.
NOT
E:
If a desktop charger then
I06
is used to communicate to the Gemini the status
of the charging indicator on the charger.
Содержание TALKABOUT T2688
Страница 1: ...T200 T2688 Level 1 2 Service Manual Rev 1 2 ...
Страница 4: ...of 51 GSM Field Service Support iv T200 T2688 SECTION 1 GENERAL ...
Страница 8: ...of 51 GSM Field Service Support 1 T200 T2688 SECTION 2 T200 DESCRIPTION ...
Страница 15: ...of 51 GSM Field Service Support 8 T200 T2688 SECTION 3 FEATURE LIST ...
Страница 22: ...of 51 GSM Field Service Support 15 T200 T2688 SECTION 4 DISASSEMBLY PARTS ...
Страница 26: ...of 51 GSM Field Service Support 19 T200 T2688 4 5 Exploded Parts Diagram ...
Страница 28: ...of 51 GSM Field Service Support 21 T200 T2688 SECTION 5 SIM CARDS AND SECURITY ...
Страница 32: ...of 51 GSM Field Service Support 25 T200 T2688 SECTION 6 REPAIR AND TEST PROCEDURES ...
Страница 40: ...of 51 GSM Field Service Support 33 T200 T2688 SECTION 7 ACCESSORIES ...