background image

Symbologies 10 - 67

Transmit UK Postal Check Digit

Parameter # 60h

Select whether to transmit UK Postal data with or without the check digit.

Japan Postal

Parameter # F0h, 22h

To enable or disable Japan Postal, scan the appropriate bar code below.

*

Transmit UK Postal

Check Digit

(01h)

Do Not Transmit UK Postal Check Digit

(00h)

*

Enable Japan Postal

(01h)

Disable Japan Postal

(00h)

Содержание SYMBOL DS6707

Страница 1: ...Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 2: ......

Страница 3: ...Symbol DS6707 Digital Imager Scanner Product Reference Guide 72E 83978 08 Revision A December 2010 ...

Страница 4: ...ii Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 5: ...a licensed program or use a licensed program in a network without written permission from Motorola The user agrees to maintain Motorola s copyright notice on the licensed programs delivered hereunder and to include the same on any authorized copies it makes in whole or in part The user agrees not to decompile disassemble decode or reverse engineer any licensed program delivered to the user or any ...

Страница 6: ...dded Code 128 Lengths and Post US4 changed code type name from UCC EAN 128 to GS1 128 05 Rev A 10 2008 Updated wall mount template added separate dimensions and weight specifications for the Symbol DS6707 DP model added custom defaults options added specific string search and new move cursor options in ADF chapter 06 Rev A 5 2009 Added ISSN EAN Matrix 2 of 5 and Chinese 2 of 5 code types added ISB...

Страница 7: ...v ...

Страница 8: ...vi Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 9: ...cking 1 2 Setting Up the Digital Imager Scanner 1 3 Standard Model 1 3 Model with Base 1 4 Configuring the Digital Imager Scanner 1 5 Mounting the Digital Imager Scanner 1 5 Desk Mount 1 5 Wall Mount 1 6 Chapter 2 Scanning Introduction 2 1 Beeper Definitions 2 2 LED Definitions 2 4 Scanning in Hand Held Mode 2 4 Scanning with the Digital Imager Scanner 2 4 Aiming 2 6 Scanning in Presentation Mode ...

Страница 10: ...DS6707 HD High Density Digital Imager Scanner 2D Bar Codes 2 16 Chapter 3 Maintenance Technical Specifications Introduction 3 1 Maintenance 3 1 Digital Scanner 3 1 Troubleshooting 3 2 Technical Specifications 3 4 Digital Imager Scanner Signal Descriptions 3 8 Chapter 4 User Preferences Miscellaneous Digital Imager Scanner Options Introduction 4 1 Scanning Sequence Examples 4 2 Errors While Scannin...

Страница 11: ... 7 Check Parity 5 8 Software Handshaking 5 8 Host RTS Line State 5 9 Decode Data Packet Format 5 9 Stop Bit Select 5 10 Host Serial Response Time out 5 11 Host Character Time out 5 12 Multipacket Option 5 13 Interpacket Delay 5 14 Event Reporting 5 15 Decode Event 5 15 Boot Up Event 5 16 Parameter Event 5 16 Chapter 6 Imaging Preferences Introduction 6 1 Scanning Sequence Examples 6 2 Errors While...

Страница 12: ...e Capture JPEG Quality 6 23 Video View Finder 6 24 Target Video Frame Size 6 24 Video View Finder Image Size 6 25 Chapter 7 USB Interface Introduction 7 1 Connecting a USB Interface 7 2 USB Parameter Defaults 7 4 USB Host Parameters 7 5 USB Device Type 7 5 Symbol Native API SNAPI Status Handshaking 7 7 USB Country Keyboard Types Country Codes 7 8 USB Keystroke Delay 7 10 USB CAPS Lock Override 7 1...

Страница 13: ...ence Examples 10 1 Errors While Scanning 10 2 Symbology Parameter Defaults 10 2 Disable All Code Types 10 7 UPC EAN 10 8 Enable Disable UPC A 10 8 Enable Disable UPC E 10 8 Enable Disable UPC E1 10 9 Enable Disable EAN 8 JAN 8 10 9 Enable Disable EAN 13 JAN 13 10 10 Enable Disable Bookland EAN 10 10 Decode UPC EAN JAN Supplementals 10 11 User Programmable Supplementals 10 14 UPC EAN JAN Supplement...

Страница 14: ... Set Lengths for Code 11 10 43 Code 11 Check Digit Verification 10 45 Transmit Code 11 Check Digits 10 46 Interleaved 2 of 5 ITF 10 47 Enable Disable Interleaved 2 of 5 10 47 Set Lengths for Interleaved 2 of 5 10 47 I 2 of 5 Check Digit Verification 10 49 Transmit I 2 of 5 Check Digit 10 49 Convert I 2 of 5 to EAN 13 10 50 Discrete 2 of 5 DTF 10 51 Enable Disable Discrete 2 of 5 10 51 Set Lengths ...

Страница 15: ...S1 DataBar Limited 10 72 GS1 DataBar Expanded 10 73 Convert GS1 DataBar to UPC EAN 10 73 Composite 10 74 Composite CC C 10 74 Composite CC A B 10 74 Composite TLC 39 10 75 UPC Composite Mode 10 76 Composite Beep Mode 10 77 GS1 128 Emulation Mode for UCC EAN Composite Codes 10 77 2D Symbologies 10 78 Enable Disable PDF417 10 78 Enable Disable MicroPDF417 10 78 Code 128 Emulation 10 79 Data Matrix 1...

Страница 16: ...ds 11 8 Pause Duration 11 8 Begin New Rule 11 8 Save Rule 11 8 Erase 11 9 Quit Entering Rules 11 9 Disable Rule Set 11 10 Criteria 11 11 Code Types 11 11 Code Lengths 11 19 Message Containing A Specific Data String 11 23 Actions 11 28 Send Data 11 28 Setup Field s 11 31 Modify Data 11 38 Pad Data with Spaces 11 39 Pad Data with Zeros 11 43 Beeps 11 48 Send Keystroke Control Characters and Keyboard...

Страница 17: ... 1 EAN 13 100 C 2 Code 128 C 2 Interleaved 2 of 5 C 2 GS1 DataBar 14 C 3 PDF417 C 3 Data Matrix C 3 Maxicode C 4 QR Code C 4 US Postnet C 4 UK Postal C 5 Appendix D Numeric Bar Codes Numeric Bar Codes D 1 Cancel D 2 Appendix E ASCII Character Sets Glossary Index Tell Us What You Think ...

Страница 18: ...xvi Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 19: ...for high density 1D and 2D bar codes Symbol DS6707 HC Standard Range digital imager scanner healthcare white Symbol DS6707 DP Direct Part Mark digital imager scanner for DPM scanning Symbol DS6707 DC Document Capture digital imager scanner for 8 1 2 in by 11 in imaging Chapter Descriptions Topics included in this guide are as follows Chapter 1 Getting Started provides a product overview unpacking ...

Страница 20: ...gy features and provides programming bar codes for selecting these features for the digital imager scanner Chapter 11 Advanced Data Formatting ADF describes how to customize scanned data before transmitting to the host Appendix A Standard Default Parameters provides a table of all host devices and miscellaneous scanner defaults Appendix B Programming Reference provides a table of AIM code identifi...

Страница 21: ...pportcentral motorola com When contacting Motorola Inc support please have the following information available Serial number of the unit Model number or product name Software type and version number Motorola responds to calls by e mail telephone or fax within the time limits set forth in service agreements If your problem cannot be solved by Motorola Inc Support you may need to return your equipme...

Страница 22: ...xx Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 23: ... transfer to provide the best value in a digital imager scanner Whether in hand held mode or presentation hands free mode the digital imager scanner ensures comfort and ease of use for extended periods of time Figure 1 1 Symbol DS6707 Digital Imager Scanner Figure 1 2 Symbol DS6707 Digital Imager Scanner with Base Scan Window Trigger LED Beeper Base Angle Adjustment Knob 2 ...

Страница 24: ...todetects a USB host and defaults to the HID keyboard interface type Select other USB interface types by scanning programming bar code menus This interface supports the following international keyboards for Windows environment North America German French French Canadian Spanish Italian Swedish UK English Portuguese Brazilian and Japanese Configuration via 123Scan Unpacking Remove the digital image...

Страница 25: ...information on host connections Figure 1 3 Installing the Cable Removing the Interface Cable 1 Using the tip of a screwdriver depress the cable s modular connector clip Figure 1 4 Removing the Cable 2 Carefully slide out the cable 3 Follow the steps for Installing the Interface Cable to connect a new cable Clip To host Cable interface port Interface cable modular connector NOTE Different hosts req...

Страница 26: ... until there is full access to the cable interface port on the bottom of the scanner Figure 1 5 Adjust the Scanner for Cable Installation 3 Insert the interface cable through the opening at the back of the base 4 Plug the interface cable modular connector into the cable interface port on the bottom of the scanner handle 5 Gently tug the cable to ensure the connector is properly secured 6 Move the ...

Страница 27: ... Chapter 6 Imaging Preferences for information about programming the digital imager scanner using bar code menus Also see each host specific chapter to set up connection to a specific host type 1 See Chapter 9 123Scan2 to configure the digital imager scanner using this configuration program The program includes a help file Mounting the Digital Imager Scanner Desk Mount Use the optional desk mount ...

Страница 28: ...wo screws appropriate for the mounting surface through the screw holes on the mount and into the surface Insert the digital imager scanner into the mount as shown Figure 1 7 Securing the Wall Mount The recommended screws are two 6 screws 1 long and two 6 washers For convenience print this page and use the template below for mounting hole locations Figure 1 8 Wall Mounting Template 2 98 Insert moun...

Страница 29: ...Chapter 2 Scanning Introduction This chapter provides beeper and LED definitions techniques involved in scanning bar codes general instructions and tips about scanning and decode zone diagrams ...

Страница 30: ... sequence performed Low high beeps Input error incorrect bar code programming sequence or Cancel scanned remain in ADF program mode High low beeps Keyboard parameter selected Enter value using numeric bar codes High low high low beeps Successful program exit with change in parameter setting Low high low high beeps Out of host parameter storage space Scan Set Default Parameter on page 4 4 Code 39 B...

Страница 31: ...t necessary to re enter the current rule Low high low beeps Cancel rule entry Rule entry mode exited because of an error or the user asked to exit rule entry Low high beeps Entry error wrong bar code scanned Re enter criterion or action All previously entered criteria and actions are retained Criteria or action list is too long for a rule Host Specific USB only 4 short high beeps The digital image...

Страница 32: ... on page 1 3 For assistance contact the local supplier or Motorola Inc Support Scanning with the Digital Imager Scanner 1 Ensure all connections are secure see the appropriate host chapter 2 Aim the digital imager scanner at the bar code Figure 2 1 Scanning in Hand Held Mode Table 2 2 Standard LED Definitions LED Indication Off No power is applied to the digital imager scanner or the digital image...

Страница 33: ...e entire symbol is within the rectangular area formed by the brackets in the pattern When scanning with the DS6707 DP ensure part of the bar code is visible on the inside of the donut shaped pattern Figure 2 3 Placing Symbol in Aiming Pattern 5 Hold the trigger until the digital imager scanner beeps indicating the bar code is successfully decoded For more information on beeper and LED definitions ...

Страница 34: ...e symbol Scan symbols with smaller bars or elements mil size closer to the digital imager scanner and those with larger bars or elements mil size farther from the digital imager scanner The digital imager scanner can also read a bar code presented within the aiming pattern but not centered The top examples in Figure 2 4 and Figure 2 5 show acceptable aiming options while the bottom examples can no...

Страница 35: ... imager scanner in the IntelliStand 1 Connect the digital imager scanner to the host see the appropriate host chapter for information on host connections 2 Insert the digital imager scanner in the Intellistand by placing the front of the digital imager scanner into the stand s cup see Figure 2 6 3 Use the Intellistand s adjustment knobs to adjust the height and angle of the digital imager scanner ...

Страница 36: ... aiming pattern The entire symbol must be within the brackets 4 Upon successful decode the digital imager scanner beeps and the LED turns green For more information on beeper and LED definitions see Table 2 1 and Table 2 2 Switching to Hand Held Mode 1 Lift the scanner for hand held use 2 Center the symbol in the aiming pattern The entire symbol must be within the brackets 3 Pull the trigger Upon ...

Страница 37: ...e Decode Zone for 1D Bar Codes In c m 0 0 DS6707 SR 5 mil Code 39 5 4 13 mil 100 UPC EAN 8 4 12 9 0 5 5 In c m W i d t h o f F i e l d 10 10 0 12 7 12 7 25 4 3 1 6 0 9 20 mil Code 39 Note Typical performance at 73 4 F 23 C on high quality symbols Depth of Field 5 12 7 10 25 4 15 38 1 0 9 0 9 O O Postnet 12 5 2 6 10 mil I 2 of 5 7 9 1 0 ...

Страница 38: ...Range Decode Zone for 2D Bar Codes In c m 0 0 DS6707 SR 6 2 7 50 0 5 5 In c m W i d t h o f F i e l d 10 10 0 12 7 12 7 25 4 3 1 6 PDF417 10 mil Datamatrix 10 mil Note Typical performance at 73 4 F 23 C on high quality symbols Depth of Field 5 12 7 10 25 4 15 38 1 O O 1 4 1 10 35 mil Maxicode 12 8 1 5 10 mil MicroPDF 7 50 2 3 10 mil QR Code 6 6 mil PDF417 2 6 6 8 1 4 5 2 ...

Страница 39: ...Zone for 1D Bar Codes In c m 0 0 DS6707 DC 5 mil Code 39 8 4 13 mil 100 UPC EAN 14 7 21 4 0 5 5 In c m W i d t h o f F i e l d 10 10 0 12 7 12 7 25 4 0 9 20 mil Code 39 Note Typical performance at 73 4 F 23 C on high quality symbols Depth of Field 5 12 7 10 25 4 15 38 1 20 50 8 2 6 1 2 O O 25 63 5 15 38 1 25 4 15 38 1 Postnet 12 5 2 6 10 mil I 2 of 5 1 7 13 7 ...

Страница 40: ...code Zone for 2D Bar Codes In c m 0 0 DS6707 DC 11 1 12 2 0 2 5 2 5 In c m W i d t h o f F i e l d 5 5 0 6 4 6 4 12 7 PDF417 10 mil Datamatrix 10 mil Note Typical performance at 73 4 F 23 C on high quality symbols Depth of Field 2 5 6 4 5 12 7 7 5 19 1 10 25 4 O O 2 4 2 6 12 5 31 8 7 5 19 1 12 7 7 5 19 1 10 mil MicroPDF 10 mil QR Code 6 6 mil PDF417 2 6 6 8 3 2 8 2 2 3 7 5 15 38 1 35 mil Maxicode ...

Страница 41: ... Bar Codes In c m 0 0 DS6707 DP 7 5 mil Code 39 2 96 3 05 0 1 1 In c m W i d t h o f F i e l d 2 0 2 5 15 mil PDF417 Note Typical performance at 73 4 F 23 C on high quality symbols Depth of Field 2 5 1 4 10 2 6 15 2 O O 0 92 5 1 2 5 2 5 1 3 mil Code 39 1 21 4 mil Code 39 1 83 5 mil Code 39 1 96 10 mil Code 39 3 50 20 mil Code 39 6 21 13 mil 100 UPC 3 59 1 59 6 67 mil PDF417 2 21 10 mil PDF417 ...

Страница 42: ...r 2D Bar Codes In c m 0 0 DS6707 DP 4 mil Data Matrix 1 0 0 0 25 0 25 In c m W i d t h o f F i e l d 0 5 0 5 0 0 64 0 64 1 27 Note Typical performance at 73 4 F 23 C on high quality symbols Depth of Field 0 5 1 27 1 2 54 1 5 3 81 2 5 08 O O 2 5 6 35 0 75 1 9 1 27 0 75 1 9 5 mil Data Matrix 1 29 7 5 mil Data Matrix 1 71 10 mil Data Matrix 2 13 4 mil QR Code 1 0 5 mil QR Code 1 25 7 5 mil QR Code 1 ...

Страница 43: ...l Code 39 3 38 13 mil 100 UPC EAN 3 54 0 2 In c m W i d t h o f F i e l d 3 0 5 1 7 6 10 mil PDF417 Note Typical performance at 73 4 F 23 C on high quality symbols Depth of Field 2 5 1 4 10 2 6 15 2 8 20 3 0 29 O O 0 46 1 2 5 1 2 5 2 5 1 3 7 6 3 mil Code 39 2 42 0 84 4 mil Code 39 3 13 0 42 7 5 mil Code 39 4 38 10 mil Code 39 4 96 0 59 20 mil Code 39 8 21 0 42 5 13 0 21 3 10 6 67 mil PDF417 0 63 4...

Страница 44: ...HD 4 mil Data Matrix 2 13 0 0 5 0 5 In c m W i d t h o f F i e l d 1 0 1 0 0 1 27 1 27 2 54 Note Typical performance at 73 4 F 23 C on high quality symbols Depth of Field 0 5 1 27 1 2 54 1 5 3 81 2 5 08 O O 2 5 6 35 1 5 3 81 2 54 1 5 3 81 5 mil Data Matrix 2 50 7 5 mil Data Matrix 3 00 10 mil Data Matrix 3 50 4 mil QR Code 2 17 5 mil QR Code 2 54 7 5 mil QR Code 3 00 10 mil QR Code 3 42 3 7 62 3 5...

Страница 45: ...l to touch the window Remove any dirt particles with a damp cloth Wipe the window using a tissue moistened with ammonia water Do not spray water or other cleaning liquids directly into the window The DS6707 HC design allows safe cleansing of the product plastics with a variety of cleaning products and disinfectants If required wipe the digital imager scanner with the following list of approved cle...

Страница 46: ... 4 18 Scanner emits short low short medium short high beep sequence power up beep sequence more than once The USB bus may put the digital imager scanner in a state where power to the digital imager scanner is cycled on and off more than once Normal during host reset Digital imager scanner emits aiming pattern but does not decode the bar code Digital imager scanner is not programmed for the correct...

Страница 47: ...atch the host s settings Program the proper editing options e g UPC E to UPC A Conversion Digital imager scanner emits high high high low beeps when not in use RS 232 receive error Normal during host reset Otherwise set the digital imager scanner s RS 232 parity to match the host setting Digital imager scanner emits low high beeps during programming Input error or Cancel bar code was scanned Scan ...

Страница 48: ... in Cash Register White Performance Characteristics Light Source Aiming 650 nm laser diode Illumination 630 nm LED Field of View Vertical x Horizontal Document Capture 35º V x 44º H Standard Range Direct Part Mark High Density 34º V x 43º H Roll Pitch Yaw 360º 65º 60º Symbology Decode Capability 1D UPC EAN and with supplementals Bookland EAN ISSN EAN Code 128 Code 128 Full ASCII GS1 128 ISBT 128 C...

Страница 49: ...0 mil PDF417 2 4 11 1 in 6 1 28 2 cm 10 mil QR Code 2 6 6 8 in 6 6 17 3 cm 10 mil MicroPDF 2 3 7 5 in 5 8 19 1 cm 10 mil Data Matrix 2 6 12 2 in 6 6 31 0 cm 35 mil Maxicode 1 5 12 8 in 3 8 32 5 cm Typical Working Distance DP Direct Part Mark focus 3 mil Code 39 Up to 1 21 in 3 07 cm 4 mil Code 39 Up to 1 83 in 4 65 cm 5 mil Code 39 Up to 1 96 in 4 98 cm 7 5 mil Code 39 Up to 2 96 in 7 52 cm 10 mil...

Страница 50: ... 10 mil QR Code 0 46 3 42 in 1 17 8 69 cm Print Contrast 25 minimum reflectance Motion Tolerances Horizontal Velocity 5 in 12 7 cm per second Interfaces Supported RS 232C Standard Nixdorf ICL Fujitsu and USB Standard IBM SurePOS Macintosh allows for connectivity to all of the above plus many non standard interfaces Imaging Characteristics Image of Pixels 1 3 Mega Pixel 1280 H x 1024 V Graphics For...

Страница 51: ...condensing Drop Specifications For Scanner Only Not Including Base Withstands multiple 5 ft 1 52 m drops to concrete at operating temperature extremes and multiple 6 ft 1 8 m drops to concrete at room temperature 23º C Ambient Light Immunity Immune to normal artificial indoor and natural outdoor direct sunlight lighting Table 3 2 Technical Specifications Continued Item Description ...

Страница 52: ...n the Symbol DS6707 digital imager scanner and are for reference only Table 3 3 Symbol DS6707 Digital Imager Scanner Signal Pin outs Pin RS 232 SSI USB 1 Reserved Jump to Pin 6 2 Power Power 3 Ground Ground 4 TxD Reserved 5 RxD D 6 RTS Jump to Pin 1 7 CTS D 8 Reserved Reserved 9 Reserved Reserved 10 Reserved Reserved Pin 10 Bottom of digital imager scanner Pin 1 Interface cable modular connector C...

Страница 53: ...on volatile memory and are preserved even when you power down the digital imager scanner If not using a USB cable select a host type after the power up beeps sound See Chapter 5 SSI Interface Chapter 7 USB Interface and Chapter 8 RS 232 Interface for specific host information This is only necessary upon the first power up when connected to a new host To return all features to default values scan t...

Страница 54: ...ate bar codes in this guide These new values replace the standard default values in memory To recall the default parameter values see the Set Default Parameter on page 4 4 Download data through the device s serial port using SSI Hexadecimal parameter numbers appear in this chapter below the parameter title and options appear in parenthesis beneath the accompanying bar codes Refer to the Simple Ser...

Страница 55: ...lumination F0h 2Ah Enable 4 16 DP Illumination F1h 3Bh Auto 4 17 Decode Aiming Pattern F0h 32h Enable 4 18 Fuzzy 1D Processing F1h 02h Enable 4 18 Decode Mirror Images F1h 19h Never 4 19 Miscellaneous Options Transmit Code ID Character 2Dh None 4 20 Prefix Value 63h 69h 7013 CR LF 4 21 Suffix 1 Value Suffix 2 Value 62h 68h 64h 6Ah 7013 CR LF 4 21 Scan Data Transmission Format EBh Data as is 4 22 F...

Страница 56: ...et custom defaults by scanning Write to Custom Defaults scan Restore Defaults to retrieve and restore the scanner s custom default settings If you did not set custom defaults scan Restore Defaults to restore the factory default values listed in Table A 1 Set Factory Defaults Scan this bar code to restore the factory default values listed in Table A 1 This deletes any custom defaults set Write to C...

Страница 57: ...can the Disable Parameter Scanning bar code below To re enable decoding of parameter bar codes scan Enable Parameter Scanning Beeper Tone Parameter 91h To select a decode beep frequency tone scan the Low Frequency Medium Frequency or High Frequency bar code Enable Parameter Scanning 01h Disable Parameter Scanning 00h Low Frequency 02h Medium Frequency Optimum Setting 01h High Frequency 00h ...

Страница 58: ...a beeper volume scan the Low Volume Medium Volume or High Volume bar code Suppress Power up Beeps Parameter F1h D1h Select whether or not to suppress the digital imager scanner s power up beeps Low Volume 02h Medium Volume 01h High Volume 00h Do Not Suppress Power up Beeps 00h Suppress Power up Beeps 01h ...

Страница 59: ...each decode attempt In continuous power mode power remains on after each decode attempt Time Delay to Low Power Mode Parameter 92h This parameter sets the time the digital imager scanner remains active after decoding The digital imager scanner wakes upon trigger pull or when the host attempts to communicate with the digital imager scanner Continuous On 00h Reduced Power Mode 01h NOTE This paramete...

Страница 60: ...4 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide 5 Minutes 25h 15 Minutes 2Bh 1 Hour 31h ...

Страница 61: ...ation hands free mode The digital imager scanner activates decode processing when it detects a bar code in its field of view Decoding range is reduced in this mode Auto Aim This trigger mode turns on the red laser aiming pattern when the digital imager scanner senses motion A trigger pull activates decode processing After 2 seconds of inactivity the red laser aiming pattern automatically shuts off...

Страница 62: ...t one of the following picklist modes for the digital imager scanner Disabled Always Picklist mode is always disabled Enabled Out of Scanstand Picklist mode is enabled when the digital imager scanner is out of presentation scanstand mode and disabled when the digital imager scanner is in presentation mode Enabled Always Picklist mode is always enabled Disabled Always 00h Enabled Out of Scanstand 0...

Страница 63: ... in hands free mode until the trigger is pulled and released at which point the digital imager scanner will revert to the current trigger mode setting If the trigger is unused for the duration of the time delay mode the digital imager scanner will remain in hands free mode Simulated Scan Base Operation When using the Digital Imager Scanner with Base see Figure 1 2 on page 1 1 this parameter is ena...

Страница 64: ...lPresentation Time Delay Mode continued 6 Secs 7 Secs 8 Secs 9 Secs NOTE The Digital Imager Scanner default is Disable for the Presentation Time Delay Mode parameter The Digital Imager Scanner with Base default is 3 Secs for the Presentation Time Delay Mode parameter ...

Страница 65: ...Parameter F1h CCh This mode improves bar code reading performance off mobile phones and electronic displays Enable this in hand held hands free or both modes or disable this Disable Mobile Phone Display Mode 00h Enable in Hand Held Mode 01h Enable in Hands Free Mode 02h Enable in Both Modes 03h ...

Страница 66: ...his mode is used to decode bar codes from the LCD display This parameter is used to adjust the aggressiveness of cell phone bar code reading versus paper label bar code reading NOTE When higher cell phone aggressiveness parameter settings are used it may impact the paper label bar code reading Low 04h Medium 07h High odh ...

Страница 67: ... Timeout of 0 5 seconds scan the bar code below then scan the 0 and 5 bar codes To correct an error or change the selection scan Cancel on page D 2 Timeout Between Decodes Same Symbol Parameter 89h Use this option in presentation hands free mode to prevent the beeper from continuously beeping when a symbol is left in the digital imager scanner s field of view It is programmable in 0 1 second incre...

Страница 68: ...or conditions Decoding Illumination Parameter F0h 2Ah Selecting Enable Decoding Illumination causes the digital imager scanner to flash illumination to aid decoding Select Disable Decoding Illumination to prevent the digital imager scanner from using decoding illumination Enabling illumination usually results in superior images The effectiveness of the illumination decreases as the distance to the...

Страница 69: ...ns are Auto Illumination Alternates direct and indirect illumination Direct Illumination Optimizes scanning of symbols printed on low contrast or opaque surfaces For best results hold the scanner at an angle when scanning using this option Indirect Illumination Optimizes scanning of symbols printed on mirror like or shiny surfaces Auto Illumination 01h Direct Illumination 02h Indirect Illumination...

Страница 70: ...ff Fuzzy 1D Processing Parameter F1h 02h This option is enabled by default to optimize decode performance on 1D bar codes including damaged and poor quality symbols Disable this only if you experience time delays when decoding 2D bar codes or in detecting a no decode NOTE With picklist enabled the decode aiming pattern flashes even when the Decode Aiming Pattern is disabled Enable Decode Aiming Pa...

Страница 71: ... Parameter F1h 19h Select an option for decoding mirror image Data Matrix bar codes Always decode only Data Matrix bar codes that are mirror images Never do not decode Data Matrix bar codes that are mirror images Auto decode both mirrored and unmirrored Data Matrix bar codes Never 00h Always 01h Auto 02h ...

Страница 72: ...tal imager scanner is decoding more than one code type In addition to any single character prefix already selected the Code ID character is inserted between the prefix and the decoded symbol Select no Code ID character a Symbol Code ID character or an AIM Code ID character For Code ID Characters see Symbol Code Identifiers on page B 1 and AIM Code Identifiers on page B 3 Symbol Code ID Character 0...

Страница 73: ...four bar codes from Appendix D Numeric Bar Codes that corresponds to that value See Table E 1 on page E 1 for the four digit codes When using host commands to set the prefix or suffix set the key category parameter to 1 then set the 3 digit decimal value See Table E 1 on page E 1 for the four digit codes To correct an error or change a selection scan Cancel on page D 2 NOTE To use Prefix Suffix va...

Страница 74: ...ata format scan one of the following bar codes corresponding to the desired format To set values for the prefix and or suffix see Prefix Suffix Values on page 4 21 NOTE If using this parameter do not use ADF rules to set the prefix suffix Data As Is 00h DATA SUFFIX 1 01h DATA SUFFIX 2 02h DATA SUFFIX 1 SUFFIX 2 03h PREFIX DATA 04h ...

Страница 75: ...alue See the ASCII Character Set table for the current host interface for the desired value To select a FN1 substitution value via bar code menus 1 Scan the bar code below 2 Locate the keystroke desired for FN1 Substitution in the ASCII Character Set table for the current host interface Enter the 4 digit ASCII value by scanning each digit in Appendix D Numeric Bar Codes To correct an error or chan...

Страница 76: ...ad Message Parameter 5Eh Scan a bar code below to select whether or not to transmit a No Read message Enable this to transmit the characters NR when a bar code is not decoded Disable this to send nothing to the host if a symbol does not decode Enable No Read 01h Disable No Read 00h ...

Страница 77: ...s Throughout the programming bar code menus default values are indicated with asterisks Baud Rate 9600 06h Feature Option Indicates Default Option Hex Value for programming via SSI command NOTE Most computer monitors allow scanning the bar codes directly on the screen When scanning from the screen be sure to set the document magnification to a level where you can see the bar code clearly and bars ...

Страница 78: ...or of the interface cable to the cable interface port on the digital imager scanner see Installing the Interface Cable on page 1 3 2 Connect the other end of the interface cable to the serial port on the host 3 Connect the power supply to the serial connector end of the interface cable Plug the power supply into an appropriate outlet Interface Cable Serial Port Connector to Host Power Supply Cable...

Страница 79: ...erface 5 3 4 Scan the appropriate baud rate bar code from Baud Rate on page 5 5 that matches the host s baud rate setting 5 To modify any other parameter options scan the appropriate bar codes in this chapter ...

Страница 80: ... A Standard Default Parameters for all user preferences hosts symbologies and miscellaneous default parameters Table 5 1 SSI Interface Parameter Defaults Parameter Parameter Number Default Page Number Baud Rate 9Ch 9600 5 5 Parity 9Eh None 5 7 Check Parity 97h Enable 5 8 Software Handshaking 9Fh ACK NAK 5 8 Host RTS Line State 9Ah Low 5 9 Decode Data Packet Format EEh Send Raw Decode Data 5 9 Stop...

Страница 81: ...canner s baud rate to match the data rate setting of the host device Otherwise data may not reach the host or may reach it in distorted form To enable the SSI host scan the appropriate baud rate bar code that matches the baud rate setting of the host device Baud Rate 600 02h Baud Rate 1200 03h Baud Rate 2400 04h Baud Rate 4800 05h Baud Rate 9600 06h ...

Страница 82: ...5 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide Baud Rate continued Baud Rate 19 200 07h 38 400 08h 57 600 0Ah 115 200 0Bh 230 400 0Ch ...

Страница 83: ...ice requirements Select Odd parity to set the parity bit to a value 0 or 1 based on data to ensure that the coded character contains an odd number of 1 bits Select Even parity to set the parity bit to a value 0 or 1 based on data to ensure that the coded character contains an even number of 1 bits If no parity is required select None Odd 00h Even 01h None 04h ...

Страница 84: ...ing If you select this option the decoder neither generates nor expects ACK NAK handshaking packets Enable ACK NAK Handshaking If you select this option after transmitting data the digital imager scanner expects either an ACK or NAK response from the host The digital imager scanner also ACKs or NAKs messages from the host The digital imager scanner waits up to the programmable Host Serial Response...

Страница 85: ...ee Decode Data Packet Format on page 5 9 If transmission errors occur in this mode the host PC may be asserting hardware handshaking lines which interfere with the SSI protocol Scan the Host RTS High bar code to address this problem Decode Data Packet Format Parameter EEh This parameter selects whether to transmit decoded data in raw format unpacketed or with the packet format defined by the seria...

Страница 86: ...h The stop bit s at the end of each transmitted character marks the end of transmission of one character and prepares the receiving host device for the next character in the serial data stream Set the number of stop bits one or two to match host device requirements 1 Stop Bit 01h 2 Stop Bits 02h ...

Страница 87: ...der wants to send and the host was already granted permission to send the decoder waits for the designated time out before declaring an error To set the delay period options are 2 5 7 5 or 9 9 seconds scan one of the following bar codes NOTE Other values are available via SSI command Low 2 Seconds 14h Medium 5 Seconds 32h High 7 5 Seconds 4Bh Maximum 9 9 Seconds 63h ...

Страница 88: ...imum time the decoder waits between characters transmitted by the host before discarding the received data and declaring an error To set the delay period options are 200 500 750 or 990 ms scan one of the following bar codes NOTE Other values are available via SSI command Low 200 ms 0Ah Medium 500 ms 32h High 750 ms 4Bh Maximum 990 ms 63h ...

Страница 89: ...ager scanner sends data packets continuously with no ACK NAK handshaking to pace the transmission The host if overrun can use hardware handshaking to temporarily delay digital imager scanner transmissions At the end of transmission the digital imager scanner waits for a CMD_ACK or CMD_NAK Multi Packet Option 3 Option 3 is the same as option 2 with the addition of a programmable interpacket delay M...

Страница 90: ...his parameter specifies the interpacket delay when Multipacket Option 3 is selected To set the delay period options are 0 25 50 75 or 99 ms scan one of the following bar codes NOTE Other values are available via SSI command Minimum 0 ms 00h Low 25 ms 19h Medium 50 ms 32h High 75 ms 4Bh Maximum 99 ms 63h ...

Страница 91: ...vent Parameter F0h 00h When enabled the digital imager scanner generates a message to the host when it successfully decodes a bar code When disabled no notification is sent Table 5 2 Event Codes Event Class Event Code Reported Decode Event Non parameter decode 0x01 Boot Up Event System power up 0x03 Parameter Event Parameter entry error Parameter stored Defaults set and parameter event is enabled ...

Страница 92: ...en power is applied When disabled no notification is sent Parameter Event Parameter F0h 03h When enabled the digital imager scanner generates a message to the host when one of the events specified in Table 5 2 on page 5 15 occurs When disabled no notification is sent Enable Boot Up Event 01h Disable Boot Up Event 00h Enable Parameter Event 01h Disable Parameter Event 00h ...

Страница 93: ... and are preserved even when you power down the digital imager scanner If not using a USB cable select a host type after the power up beeps sound See Chapter 5 SSI Interface Chapter 7 USB Interface and Chapter 8 RS 232 Interface for specific host information This is only necessary upon the first power up when connecting to a new host To return all features to default values scan the Set Default Pa...

Страница 94: ...ry To recall the default parameter values scan the Set Default Parameter on page 4 4 Download data through the device s serial port using SSI Hexadecimal parameter numbers appear in this chapter below the parameter title and options appear in parenthesis beneath the accompanying bar codes Refer to the Simple Serial Interface SSI Programmer s Guide for detailed instructions for changing parameters ...

Страница 95: ...Off 0 6 16 Image File Format Selection F0h 30h JPEG 6 17 Image Rotation F1h 99h 0 6 18 Bits per Pixel BPP F0h 2Fh 8 BPP 6 19 Signature Capture 5Dh Disable 6 20 Signature Capture Image File Format Selection F0h 39h JPEG 6 21 Signature Capture Bits per Pixel BPP F0h 3Ah 8 BPP 6 22 Signature Capture Width F4h F0h 6Eh 400 6 23 Signature Capture Height F4h F0h 6Fh 100 6 23 Signature Capture JPEG Qualit...

Страница 96: ...e In Snapshot Mode the digital imager scanner turns on its laser aiming pattern to highlight the area to capture in the image The next trigger pull instructs the digital imager scanner to capture a high quality image and transmit it to the host A short time may pass less than 2 seconds between when the trigger is pulled and the image is captured as the digital imager scanner adjusts to the lightin...

Страница 97: ...onditions Presentation Mode Field of View Parameter F1h 61h In presentation mode the scanner searches for a bar code in a smaller region around the aiming pattern s center cross to speed search time To use a full field of view scan Presentation Mode Full Field of View This allows the scanner to search the larger area of the aiming pattern Enable Low Light Enhancement 01h Disable Low Light Enhancem...

Страница 98: ...ommended for advanced users with difficult image capture situations Image Capture Illumination Parameter F0h 69h Selecting Enable Image Capture Illumination causes the digital imager scanner to flash on every image capture Select Disable Image Capture Illumination to prevent the digital imager scanner from using artificial illumination Enabling illumination usually results in superior images The e...

Страница 99: ...arameter controls the illumination banks on the scan engine Options are Full Enables the full illumination system default Auto Switches the illumination system from left to right bank Left Enables the left bank Right Enables the right bank Full 00h Auto 01h Left 02h Right 03h ...

Страница 100: ... a Fixed Exposure value of 99 scan 0 0 9 9 See Appendix D Numeric Bar Codes for numeric bar codes Fixed Gain Parameter F1h 38h Type Byte Range 1 100 This parameter configures the gain setting used in manual mode for both Decode and Snapshot Video Video viewfinder modes A value of 1 indicates that gain is not used for image capture A value of 100 indicates that maximum gain is used for image captur...

Страница 101: ... the digital imager scanner favors longer exposure time rather than higher gain to capture an image This ensures that the image is less noisy and produces fewer artifacts during post processing activities like image enhancement sharpening The mode is recommended for fixed mount fixed object image capture since the image acquired is susceptible to motion blur Scan Autodetect default to set a mode i...

Страница 102: ...To set this timeout value scan the bar code below followed by a bar code from Appendix D Numeric Bar Codes The default value is 0 which represents 30 seconds values increment by 30 For example 1 60 seconds 2 90 seconds etc Snapshot Aiming Pattern Parameter F0h 2Ch Select Enable Snapshot Aiming Pattern to project the aiming pattern when in Snapshot Mode or Disable Snapshot Aiming Pattern to turn th...

Страница 103: ...x 1024 pixels Select Enable Image Cropping to crop the image to the pixel addresses set in Crop to Pixel Addresses on page 6 12 NOTE The digital imager scanner has a cropping resolution of 4 pixels Setting the cropping area to less than 3 pixels transfers the entire image Enable Image Cropping 01h Disable Image Cropping Use Full 1280 x 1024 Pixels 00h ...

Страница 104: ...w pixel addresses and Left and Right correspond to column pixel addresses For example for a 4 row x 8 column image in the extreme bottom right section of the image set the following values Top 1020 Bottom 1023 Left 1272 Right 1279 To set the crop to pixel address scan each pixel address bar code below followed by four numeric bar codes representing the value Leading zeros are required For example ...

Страница 105: ... compression Multiple pixels are combined to one pixel resulting in a smaller image containing the original content with reduced resolution Select one of the following values Resolution Value Uncropped Image Size Full 1280 x 1024 1 2 640 x 512 1 4 320 x 160 Full Resolution 00h 1 2 Resolution 01h 1 4 Resolution 03h ...

Страница 106: ...htness below followed by three numeric bar codes representing the value Leading zeros are required For example to set an Image Brightness value of 99 scan 0 9 9 See Appendix D Numeric Bar Codes for numeric bar codes JPEG Image Options Parameter F0h 2Bh Select an option to optimize JPEG images for either size or for quality Scan the JPEG Quality Selector bar code to enter a quality value the digita...

Страница 107: ... 99 scan 0 9 9 in Appendix D Numeric Bar Codes JPEG Quality and Size Value JPEG Quality Parameter F0h 31h If you selected JPEG Quality Selector scan the JPEG Quality Value bar code followed by 3 bar codes from Appendix D Numeric Bar Codes corresponding to a value from 5 to 100 where 100 represents the highest quality image CAUTION JPEG compress may take 10 to 15 seconds based on the amount of info...

Страница 108: ...34h This parameter configures the digital imager scanner s Image Enhance feature This feature uses a combination of edge sharpening and contrast enhancement to produce an image that is visually pleasing The levels of image enhancement are Off 0 Default Low 1 Med 2 High 3 Off 0 Low 1 Medium 2 High 3 ...

Страница 109: ... Format Selector Parameter F0h 30h Select an image format appropriate for the system BMP TIFF or JPEG The digital imager scanner stores captured images in the selected format BMP File Format 03h JPEG File Format 01h TIFF File Format 04h ...

Страница 110: ...7 Digital Imager Scanner Product Reference Guide Image Rotation Parameter F1h 99h This parameter controls the rotation of the image by 0 90 180 or 270 degrees Rotate 0o 00h Rotate 90o 01h Rotate 180o 02h Rotate 270o 03h ...

Страница 111: ...BPP to assign 1 of 16 levels of grey to each pixel or 8 BPP to assign 1 of 256 levels of grey to each pixel NOTE The digital imager scanner ignores these settings for JPEG file formats which only support 8 BPP The digital imager scanner ignores 1 BPP for TIFF file formats which only support 4 BPP and 8 BPP 1 BPP is coerced to 4 BPP for TIFF file formats 1 BPP 00h 4 BPP 01h 8 BPP 02h ...

Страница 112: ...pattern is considered the signature capture area Output File Format Decoding a signature capture bar code de skews the signature image and converts the image to a BMP JPEG or TIFF file format The output data includes the file descriptor followed by the formatted signature image To enable or disable Signature Capture scan the appropriate bar code below File Descriptor Signature Image Output Format ...

Страница 113: ... Selector Parameter F0h 39h Select a signature file format appropriate for the system BMP TIFF or JPEG The digital imager scanner stores captured signatures in the selected format BMP Signature Format 03h JPEG Signature Format 01h TIFF Signature Format 04h ...

Страница 114: ... for a black and white image 4 BPP to assign 1 of 16 levels of grey to each pixel or 8 BPP to assign 1 of 256 levels of grey to each pixel NOTE The digital imager scanner ignores these settings for JPEG file formats which only support 8 BPP The digital imager scanner ignores 1 BPP for TIFF file formats which only support 4 BPP and 8 BPP 1 BPP is coerced to 4 BPP for TIFF file formats 1 BPP 00h 4 B...

Страница 115: ...alue in the range of 001 to 640 decimal Signature Capture Height Parameter F4h F0h 6Fh To set the height of the signature capture box scan the Signature Capture Height bar code followed by 3 bar codes from Appendix D Numeric Bar Codes corresponding to a value in the range of 001 to 480 decimal Signature Capture JPEG Quality Parameter F0h A5h Scan the JPEG Quality Value bar code followed by 3 bar c...

Страница 116: ...e blocks to transmit per second Selecting a smaller value transmits more frames per second but reduces video quality selecting a larger value increases video quality but slows transmission To set the Target Video Frame Size scan the bar code below followed by two bar codes from Appendix D Numeric Bar Codes corresponding to the 100 byte value from 800 to 3300 bytes For example to select 1500 bytes ...

Страница 117: ...ue transmits more frames per second selecting a larger value increases video quality To set the Video View Finder Image Size scan the bar code below followed by two bar codes from Appendix D Numeric Bar Codes corresponding to the 100 byte value from 800 to 3000 bytes For example to select 1500 bytes enter 1 5 To select 900 bytes enter 0 9 Video View Finder Image Size ...

Страница 118: ...6 26 Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 119: ...ditional power supply is required Throughout the programming bar code menus asterisks indicate default values North American Standard USB Keyboard Feature Option Indicates Default NOTE Most computer monitors allow scanning the bar codes directly on the screen When scanning from the screen be sure to set the document magnification to a level where you can see the bar code clearly and bars and or sp...

Страница 120: ...with USB capable hosts including Desktop PCs and notebooks Apple iMac G4 iBooks North America only IBM SurePOS terminals Sun IBM and other network computers that support more than one keyboard The following operating systems support the digital imager scanner through USB Windows 98 2000 ME XP MacOS 8 5 MacOS 10 3 IBM 4690 OS USB Series A Connector Interface Cable Interface Cable USB Series A Conne...

Страница 121: ...e USB device type by scanning the appropriate bar code from USB Device Type on page 7 5 4 On first installation when using Windows the software prompts to select or install the Human Interface Device driver To install this driver provided by Windows click Next through all the choices and click Finished on the last choice The digital imager scanner powers up during this installation 5 To modify any...

Страница 122: ...e 7 1 USB Interface Parameter Defaults Parameter Default Page Number USB Host Parameters USB Device Type HID Keyboard Emulation 7 5 Symbol Native API SNAPI Status Handshaking Enable 7 7 USB Country Keyboard Types Country Codes North American 7 8 USB Keystroke Delay No Delay 7 10 USB CAPS Lock Override Disable 7 10 USB Ignore Unknown Characters Enable 7 11 Emulate Keypad Disable 7 11 Emulate Keypad...

Страница 123: ...e Type Select the desired USB device type NOTE When changing USB Device Types the digital imager scanner automatically resets and issues the standard startup beep sequences HID Keyboard Emulation IBM Table Top USB IBM Hand Held USB USB OPOS Handheld ...

Страница 124: ...E Before selecting CDC COM Port Emulation install the CDC INF file on the host to ensure the digital imager scanner does not stall during power up due to a failure to enumerate USB If the digital imager scanner stalls to recover it 1 Install the CDC INF file or 2 After power up hold the trigger for 10 seconds which allows the digital imager scanner to power up using an alternate USB configuration ...

Страница 125: ...Symbol Native API SNAPI Status Handshaking After selecting a SNAPI interface as the USB device type select whether to enable or disable status handshaking Enable SNAPI Status Handshaking Disable SNAPI Status Handshaking ...

Страница 126: ...yboard type This setting applies only to the USB HID Keyboard Emulation device NOTE When changing USB country keyboard types the digital imager scanner automatically resets and issues the standard startup beep sequences North American Standard USB Keyboard German Windows French Windows French Canadian Windows 95 98 French Canadian Windows 2000 XP ...

Страница 127: ...USB Interface 7 9 USB Country Keyboard Types continued Spanish Windows Italian Windows Swedish Windows UK English Windows Japanese Windows ASCII Portuguese Brazilian Windows ...

Страница 128: ...ire slower data transmission USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device Enable this to preserve the case of the data regardless of the state of the Caps Lock key This setting is always enabled for the Japanese Windows ASCII keyboard type and can not be disabled No Delay Medium Delay 20 msec Long Delay 40 msec Override Caps Lock Key Enable Do Not Override C...

Страница 129: ...Characters for IBM devices bar codes containing at least one unknown character are not sent to the host and the scanner sounds an error beep For HID Keyboard Emulation devices the bar code characters up to the unknown character are sent and the scanner sounds an error beep Emulate Keypad Enable this to send all characters as ASCII sequences over the numeric keypad For example ASCII A transmits as ...

Страница 130: ...II A transmits as ALT MAKE 0 0 6 5 ALT BREAK USB Keyboard FN 1 Substitution This option applies only to the USB HID Keyboard Emulation device Enable this to replace any FN 1 characters in a GS1 128 bar code with a user selected Key Category and value see FN1 Substitution Values on page 4 23 to set the Key Category and Key Value Disable Keypad Emulation with Leading Zero Enable Keypad Emulation wit...

Страница 131: ...s that do not have a bold entry remain the same whether or not you enable this parameter Simulated Caps Lock Enable this to invert upper and lower case characters on the bar code as if the Caps Lock state is enabled on the keyboard This inversion occurs regardless of the state of the keyboard s Caps Lock key Disable Function Key Mapping Enable Function Key Mapping Disable Simulated Caps Lock Enabl...

Страница 132: ...the selected case USB Static CDC When disabled each device connected consumes another COM port first device COM1 second device COM2 third device COM3 etc When enabled each device connects to the same COM port No Case Conversion Convert All to Upper Case Convert All to Lower Case Enable USB Static CDC Disable USB Static CDC ...

Страница 133: ...E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M CTRL M ENTER1 1014 N CTRL N 1015 O CTRL O 1016 P CTRL P 1017 Q CTRL Q 1018 R CTRL R 1019 S CTRL S 1020 T CTRL T 1021 U CTRL U 1022 V CTRL V 1023 W CTRL W 1024 X CTRL X 1 The keystroke in bold transmits only if you enabled Function Key Mapping on page 7 13 Otherwise ...

Страница 134: ... A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 Table 7 2 USB Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Char acter Keystroke 1The keystroke in bold transmits only if you enabled Function Key Mapping on page 7 13 Otherwise the unbolded keystroke transmits ...

Страница 135: ...1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P Table 7 2 USB Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Char acter Keystroke 1 The keystroke in bold transmits only if you enabled Function Key Mapping on page 7 13 Otherwise the unbolded keystroke transmits ...

Страница 136: ... M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l Table 7 2 USB Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Char acter Keystroke 1 The keystroke in bold transmits only if you enabled Function Key Mapping on page 7 13 Otherwise the unbolded keystroke transmits ...

Страница 137: ... 7 3 USB ALT Key Character Set ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G Table 7 2 USB Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Char acter Keystroke 1The keystroke in bold transmits only if you enabled Function Key Mapping on page 7 13 Otherwise the unbolded keystroke transmits ...

Страница 138: ...W 2088 ALT X 2089 ALT Y 2090 ALT Z Table 7 4 USB GUI Key Character Set GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 Note GUI Shift Keys The Apple iMac keyboard has an apple key on either side of the space bar Windows based systems have a GUI key to the left of the left ALT key and to the right of the right ALT key Table 7 3 USB ALT Key ...

Страница 139: ...GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W Table 7 4 USB GUI Key Character Set Continued GUI Key Keystroke Note GUI Shift Keys The Apple iMac keyboard has an apple key on either side of the space bar Windows based systems have a GUI key to the left of the left ALT key and to the right of the right ALT key ...

Страница 140: ...6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 Table 7 4 USB GUI Key Character Set Continued GUI Key Keystroke Note GUI Shift Keys The Apple iMac keyboard has an apple key on either side of the space bar Windows based systems have a GUI key to the left of the left ALT key and to the right of the right ALT key ...

Страница 141: ...042 6043 6044 undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock Table 7 7 USB Extended Keypad Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 PgUp 7004 End 7005 Pg Dn Table 7 5 USB F Key Character Set Continued F Keys Keystroke ...

Страница 142: ...uide 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Down Arrow 7017 Left Arrow 7018 Right Arrow Table 7 7 USB Extended Keypad Character Set Continued Extended Keypad Keystroke ...

Страница 143: ...he programming bar code menus asterisks indicate default values NOTE The digital imager scanner uses TTL RS 232 signal levels which interface with most system architectures For system architectures requiring RS 232C signal levels Motorola offers different cables providing TTL to RS 232C conversion Contact Motorola Inc Support for more information Baud Rate 57 600 Feature Option Indicates Default N...

Страница 144: ... RS 232 interface cable to the cable interface port on the digital imager scanner see Installing the Interface Cable on page 1 3 Interface Cable Serial Port Connector to Host Power Supply Cable NOTE Interface cables vary depending on configuration The connectors illustrated in Figure 8 1 and Figure 8 2 are examples only The connectors may be different than those illustrated but the steps to connec...

Страница 145: ...ct the power supply to the serial connector end of the RS 232 interface cable Plug the power supply into an appropriate outlet 4 Select the RS 232 host type by scanning the appropriate bar code from RS 232 Host Types on page 8 7 5 To modify any other parameter options scan the appropriate bar codes in this chapter ...

Страница 146: ...nd miscellaneous default parameters Table 8 1 RS 232 Host Default Table Parameter Default Page Number RS 232 Host Parameters RS 232 Host Types Standard 8 7 Baud Rate 9600 8 8 Parity Type None 8 11 Stop Bit Select 1 Stop Bit 8 12 Data Bits 8 Bit 8 12 Check Receive Errors Enable 8 13 Hardware Handshaking None 8 13 Software Handshaking None 8 15 Host Serial Response Time out 2 Sec 8 17 RTS Line State...

Страница 147: ...S Option 3 None RTS CTS Option 3 RTS CTS Option 3 None None None Software Handshaking None None None None ACK NAK None None Serial Response Time out 9 9 Sec 2 Sec 9 9 Sec 9 9 Sec 9 9 Sec 9 9 Sec 9 9 Sec Stop Bit Select One One One One One One One ASCII Format 8 Bit 8 Bit 8 Bit 8 Bit 7 Bit 8 Bit 7 Bit Beep On BEL Disable Disable Disable Disable Disable Disable Disable RTS Line State High Low Low Lo...

Страница 148: ...ixdorf Mode B OPOS JPOS Olivetti Omron CUTE UPC A A A A A A A A UPC E E E C C C E None EAN 8 JAN 8 FF FF B B B FF None EAN 13 JAN 13 F F A A A F A Code 39 C len None M M M len C len 3 Code 39 Full ASCII None None M M None None 3 Codabar N len None N N N len N len None Code 128 L len None K K K len L len 5 I 2 of 5 I len None I I I len I len 1 Code 93 None None L L L len None None D 2 of 5 H len No...

Страница 149: ...es 1Scanning Enable RS 232 No Variant activates the RS 232 driver but does not change port settings e g parity data bits handshaking Selecting another RS 232 host type bar code changes these settings Standard RS 2321 ICL RS 232 Wincor Nixdorf RS 232 Mode A Wincor Nixdorf RS 232 Mode B Olivetti ORS4500 Omron ...

Страница 150: ...ct CUTE scan Enable Parameter Scanning 01h on page 4 5 then change the host selection Baud Rate Baud rate is the number of bits of data transmitted per second Set the digital imager scanner s baud rate to match the baud rate setting of the host device Otherwise data may not reach the host device or may reach it in distorted form OPOS JPOS Fujitsu RS 232 CUTE2 Baud Rate 600 Baud Rate 1200 ...

Страница 151: ...RS 232 Interface 8 9 Baud Rate 2400 Baud Rate 4800 ...

Страница 152: ...8 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide Baud Rate continued Baud Rate 9600 Baud Rate 19 200 Baud Rate 38 400 Baud Rate 57 600 Baud Rate 115 200 ...

Страница 153: ...ice requirements Select Odd parity to set the parity bit value to 0 or 1 based on data to ensure that the coded character contains an odd number of 1 bits Select Even parity to set the parity bit value to 0 or 1 based on data to ensure that the coded character contains an even number of 1 bits Select None when no parity bit is required Odd Even None ...

Страница 154: ...receiving device for the next character in the serial data stream Select the number of stop bits one or two based on the number the receiving terminal is programmed to accommodate Set the number of stop bits to match host device requirements Data Bits This parameter allows the digital imager scanner to interface with devices requiring a 7 bit or 8 bit ASCII protocol 1 Stop Bit 2 Stop Bits 7 Bit 8 ...

Страница 155: ...ine is de asserted the digital imager scanner asserts the RTS line and waits up to Host Serial Response Time out for the host to assert CTS When the host asserts CTS the scanner transmits data If after Host Serial Response Time out default the CTS line is not asserted the digital imager scanner sounds a transmit error and discards the data When data transmission completes the digital imager scanne...

Страница 156: ...programmed logic level However the digital imager scanner waits for CTS to be asserted before transmitting data If CTS is not asserted within Host Serial Response Time out default the digital imager scanner issues an error indication and discards the data RTS CTS Option 3 If you select Option 3 the digital imager scanner asserts RTS prior to any data transmission regardless of the state of CTS The...

Страница 157: ...eiving NAKs the digital imager scanner issues an error indication and discards the data The digital imager scanner waits up to the programmable Host Serial Response Time out to receive an ACK or NAK If the digital imager scanner does not get a response in this time it issues an error indication and discards the data There are no retries when a time out occurs ENQ If you select this option the digi...

Страница 158: ...ager scanner has data to send it waits up to Host Serial Response Time out for an XON character before transmission If it does not receive the XON within this time the digital imager scanner issues an error indication and discards the data The scanner receives an XOFF during a transmission Data transmission then stops after sending the current byte When the digital imager scanner receives an XON c...

Страница 159: ... the digital imager scanner waits for an ACK NAK or CTS before determining that a transmission error occurred This only applies when in one of the ACK NAK software handshaking modes or RTS CTS hardware handshaking mode Minimum 2 Sec Low 2 5 Sec Medium 5 Sec High 7 5 Sec Maximum 9 9 Sec ...

Страница 160: ...ode below to select Low RTS or High RTS line state Beep on BEL If you enable this parameter the digital imager scanner issues a beep when it detects a BEL character on the RS 232 serial line BEL gains a user s attention to an illegal entry or other important event Host Low RTS Host High RTS Beep On BEL Character Enable Do Not Beep On BEL Character Disable ...

Страница 161: ...S 232 Interface 8 19 Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions Minimum 0 msec Low 25 msec Medium 50 msec High 75 msec Maximum 99 msec ...

Страница 162: ...oes not recognize Select Send Bar Codes with Unknown Characters to send all bar code data except for unknown characters The scanner sounds no error beeps Select Do Not Send Bar Codes With Unknown Characters to send bar code data up to the first unknown character The scanner sounds an error beep Normal Operation Beep LED immediately after decode Beep LED After Transmission Beep LED After CTS Pulse ...

Страница 163: ...fix Suffix Value Full ASCII Code 39 Encode Character ASCII Character 1000 U NUL 1001 A SOH 1002 B STX 1003 C ETX 1004 D EOT 1005 E ENQ 1006 F ACK 1007 G BELL 1008 H BCKSPC 1009 I HORIZ TAB 1010 J LF NW LN 1011 K VT 1012 L FF 1013 M CR ENTER 1014 N SO 1015 O SI 1016 P DLE 1017 Q DC1 XON 1018 R DC2 1019 S DC3 XOFF 1020 T DC4 1021 U NAK 1022 V SYN 1023 W ETB 1024 X CAN 1025 Y EM 1026 Z SUB ...

Страница 164: ... US 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 Table 8 4 Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Character ASCII Character ...

Страница 165: ...B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V Table 8 4 Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Character ASCII Character ...

Страница 166: ...93 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t Table 8 4 Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Character ASCII Character ...

Страница 167: ...5 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S 1127 Undefined 7013 ENTER Table 8 4 Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Character ASCII Character ...

Страница 168: ...8 26 Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 169: ...tion of multi setting bar codes if the number of settings is very large stage large number of scanners simultaneously generate reports with asset tracking information and create custom products Communication with 123Scan2 To communicate with the 123Scan program which runs on a host computer running a Windows XP SP2 or Windows Vista operating system use a USB cable to connect the scanner cradle to ...

Страница 170: ...9 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 171: ...risks indicate default values Scanning Sequence Examples In most cases scanning one bar code sets the parameter value For example to transmit bar code data without the UPC A check digit simply scan the Do Not Transmit UPC A Check Digit bar code under Transmit UPC A Check Digit on page 10 17 The digital imager scanner issues a fast warble beep and the LED turns green signifying a successful paramet...

Страница 172: ...beneath the accompanying bar codes Refer to the Simple Serial Interface SSI Programmer s Guide for detailed instructions for changing parameters using this method NOTE See Appendix A Standard Default Parameters for all user preferences hosts and miscellaneous default parameters Table 10 1 Parameter Defaults Parameter Parameter Number Default Page Number Disable All Code Types 10 7 UPC EAN UPC A 01...

Страница 173: ... for Code 128 D1h D2h Any Length 10 28 GS1 128 formerly UCC EAN 128 0Eh Enable 10 30 ISBT 128 54h Enable 10 30 ISBT Concatenation F1h 41h Disable 10 31 Check ISBT Table F1h 42h Enable 10 32 ISBT Concatenation Redundancy DFh 10 10 32 Code 39 Code 39 00h Enable 10 33 Trioptic Code 39 0Dh Disable 10 33 Convert Code 39 to Code 32 Italian Pharmacy Code 56h Disable 10 34 Code 32 Prefix E7h Disable 10 34...

Страница 174: ...e 10 49 Transmit I 2 of 5 Check Digit 2Ch Disable 10 49 Convert I 2 of 5 to EAN 13 52h Disable 10 50 Discrete 2 of 5 DTF Discrete 2 of 5 05h Disable 10 51 Set Length s for D 2 of 5 14h 15h 12 10 51 Codabar NW 7 Codabar 07h Disable 10 53 Set Lengths for Codabar 18h 19h 5 to 55 10 53 CLSI Editing 36h Disable 10 55 NOTIS Editing 37h Disable 10 55 MSI MSI 0Bh Disable 10 56 Set Length s for MSI 1Eh 1Fh...

Страница 175: ...stal Check Digit 60h Enable 10 67 Japan Postal F0h 22h Enable 10 67 Australian Postal F0h 23h Enable 10 68 Australia Post Format F1h CEh Autodiscriminate 10 69 Netherlands KIX Code F0h 46h Enable 10 70 USPS 4CB One Code Intelligent Mail F1h 50h Disable 10 70 UPU FICS Postal F1h 63h Disable 10 71 GS1 DataBar GS1 DataBar 14 F0h 52h Enable 10 72 GS1 DataBar Limited F0h 53h Disable 10 72 GS1 DataBar E...

Страница 176: ...Matrix Inverse F1h 4Ch SR DC Regular DP HD Autodetect 10 81 Maxicode F0h 26h Enable 10 82 QR Code F0h 25h Enable 10 82 QR Inverse F1h 4Bh SR DC Regular DP HD Autodetect 10 83 MicroQR F1h 3Dh Enable 10 84 Aztec F1h 3Eh Enable 10 84 Aztec Inverse F1h 4Dh SR DC Regular DP HD Autodetect 10 85 Symbology Specific Security Levels Redundancy Level 4Eh 1 10 86 Security Level 4Dh 1 10 88 Intercharacter Gap ...

Страница 177: ...Symbologies 10 7 Disable All Code Types To disable all symbologies scan the bar code below This is useful when enabling only a few code types Disable All Code Types ...

Страница 178: ... EAN Enable Disable UPC A Parameter 01h To enable or disable UPC A scan the appropriate bar code below Enable Disable UPC E Parameter 02h To enable or disable UPC E scan the appropriate bar code below Enable UPC A 01h Disable UPC A 00h Enable UPC E 01h Disable UPC E 00h ...

Страница 179: ...e UPC E1 scan the appropriate bar code below Enable Disable EAN 8 JAN 8 Parameter 04h To enable or disable EAN 8 JAN 8 scan the appropriate bar code below NOTE UPC E1 is not a UCC Uniform Code Council approved symbology Enable UPC E1 01h Disable UPC E1 00h Enable EAN 8 JAN 8 01h Disable EAN 8 JAN 8 00h ...

Страница 180: ...3h To enable or disable Bookland EAN scan the appropriate bar code below Enable EAN 13 JAN 13 01h Disable EAN 13 JAN 13 00h Enable Bookland EAN 01h Disable Bookland EAN 00h NOTE If you enable Bookland EAN select a Bookland ISBN Format on page 10 24 Also select either Decode UPC EAN Supplementals Autodiscriminate UPC EAN Supplementals or Enable 978 979 Supplemental Mode in Decode UPC EAN JAN Supple...

Страница 181: ...o supplemental The scanner transmits UPC EAN bar codes that do not have that prefix immediately Enable 378 379 Supplemental Mode Enable 978 979 Supplemental Mode Enable 977 Supplemental Mode Enable 414 419 434 439 Supplemental Mode Enable 491 Supplemental Mode Enable Smart Supplemental Mode applies to EAN 13 bar codes starting with any prefix listed previously Supplemental User Programmable Type 1...

Страница 182: ...Decode UPC EAN JAN Supplementals continued Decode UPC EAN JAN Only With Supplementals 01h Ignore Supplementals 00h Autodiscriminate UPC EAN JAN Supplementals 02h Enable 378 379 Supplemental Mode 04h Enable 978 979 Supplemental Mode 05h Enable 977 Supplemental Mode 07h ...

Страница 183: ...9 Supplemental Mode 06h Enable 491 Supplemental Mode 08h Enable Smart Supplemental Mode 03h Supplemental User Programmable Type 1 09h Supplemental User Programmable Type 1 and 2 0Ah Smart Supplemental Plus User Programmable 1 0Bh Smart Supplemental Plus User Programmable 1 and 2 0Ch ...

Страница 184: ...e option from Decode UPC EAN JAN Supplementals on page 10 11 select User Programmable Supplemental 1 to set the 3 digit prefix Then select the 3 digits using the numeric bar codes beginning on page D 1 Select User Programmable Supplemental 2 to set a second 3 digit prefix Then select the 3 digits using the numeric bar codes beginning on page D 1 User Programmable Supplemental 1 User Programmable S...

Страница 185: ...e range is from two to thirty times Five or above is recommended when decoding a mix of UPC EAN JAN symbols with and without supplementals The default is set at 10 Scan the bar code below to set a decode redundancy value Next scan two numeric bar codes in Appendix D Numeric Bar Codes Enter a leading zero for single digit numbers To correct an error or change a selection scan Cancel on page D 2 UPC...

Страница 186: ...e ID Character Separate transmit UPC EAN with supplementals with separate AIM IDs but one transmission i e E 0 or 4 data E 1 or 2 supplemental data Combined transmit UPC EAN with supplementals with one AIM ID and one transmission i e E3 data supplemental data Separate Transmissions transmit UPC EAN with supplementals with separate AIM IDs and separate transmissions i e E 0 or 4 data E 1 or 2 suppl...

Страница 187: ...he integrity of the data Scan the appropriate bar code below to transmit the bar code data with or without the UPC E check digit It is always verified to guarantee the integrity of the data Transmit UPC E1 Check Digit Parameter 2Ah The check digit is the last character of the symbol used to verify the integrity of the data Scan the appropriate bar code below to transmit the bar code data with or w...

Страница 188: ...10 18 Symbol DS6707 Digital Imager Scanner Product Reference Guide Transmit UPC E1 Check Digit 01h Do Not Transmit UPC E1 Check Digit 00h ...

Страница 189: ...options for transmitting a UPC A preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and transmit no preamble Select the appropriate option to match the host system No Preamble DATA 00h System Character SYSTEM CHARACTER DATA 01h System Character Country Code COUNTRY CODE SYSTEM CHARACTER DATA 02h ...

Страница 190: ...haracter There are three options for transmitting a UPC E preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and transmit no preamble Select the appropriate option to match the host system No Preamble DATA 00h System Character SYSTEM CHARACTER DATA 01h System Character Country Code COUNTRY CODE SYSTEM CHARACTER DATA 02h ...

Страница 191: ...options for transmitting a UPC E1 preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and transmit no preamble Select the appropriate option to match the host system No Preamble DATA 00h System Character SYSTEM CHARACTER DATA 01h System Character Country Code COUNTRY CODE SYSTEM CHARACTER DATA 02h ...

Страница 192: ...to transmit UPC E decoded data as UPC E data without conversion Convert UPC E1 to UPC A Parameter 26h Enable this to convert UPC E1 decoded data to UPC A format before transmission After conversion the data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit Disable this to transmit UPC E1 decoded data as UPC E1 data without conversion Convert UPC E to UPC...

Страница 193: ... Parameter 27h Enable this to add five leading zeros to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols Disable this to transmit EAN 8 symbols as is Enable EAN JAN Zero Extend 01h Disable EAN JAN Zero Extend 00h ...

Страница 194: ...git for backward compatibility Data starting with 979 is not considered Bookland in this mode Bookland ISBN 13 The scanner reports Bookland data starting with either 978 or 979 as EAN 13 in 13 digit format to meet the 2007 ISBN 13 protocol Bookland ISBN 10 00h Bookland ISBN 13 01h NOTE For Bookland EAN to function properly first enable Bookland EAN using Enable Disable Bookland EAN on page 10 10 t...

Страница 195: ...starting with digit 99 and UPC A GS1 128 Coupon Codes UPCA EAN 13 and GS1 128 must be enabled to scan all types of Coupon Codes Enable UCC Coupon Extended Code 01h Disable UCC Coupon Extended Code 00h NOTE Use the Decode UPC EAN Supplemental Redundancy parameter to control autodiscrimination of the GS1 128 right half of a coupon code ...

Страница 196: ... field of view The scanner may report either the UPC or the Code 128 if only one is within the field of view or is readable UPC EAN JAN Supplemental Redundancy on page 10 15 controls the number of times the scanner attempts to decode the entire symbol before transmission Additionally scanning an interim coupon symbol reports UPC and scanning a new coupon symbol reports nothing no decode New Coupon...

Страница 197: ...Symbologies 10 27 ISSN EAN Parameter F1h 69h To enable or disable ISSN EAN scan the appropriate bar code below Enable ISSN EAN 01h Disable ISSN EAN 00h ...

Страница 198: ...n to decode only Code 128 symbols containing either of two selected lengths Select lengths using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only Code 128 symbols containing either 2 or 14 characters select Code 128 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or change the selection scan Cancel on page D 2 Length Within Range Select this opti...

Страница 199: ...Symbologies 10 29 Set Lengths for Code 128 continued Code 128 One Discrete Length Code 128 Two Discrete Lengths Code 128 Length Within Range Code 128 Any Length ...

Страница 200: ... GS1 128 scan the appropriate bar code below Enable Disable ISBT 128 Parameter 54h ISBT 128 is a variant of Code 128 used in the blood bank industry Scan a bar code below to enable or disable ISBT 128 If necessary the host must perform concatenation of the ISBT data Enable GS1 128 01h Disable GS1 128 00h Enable ISBT 128 01h Disable ISBT 128 00h ...

Страница 201: ... perform concatenation The digital imager scanner does not decode single ISBT symbols If you select Autodiscriminate ISBT Concatenation the digital imager scanner decodes and concatenates pairs of ISBT codes immediately If only a single ISBT symbol is present the digital imager scanner must decode the symbol the number of times set via ISBT Concatenation Redundancy on page 10 32 before transmittin...

Страница 202: ...SBT Concatenation Redundancy Parameter DFh If you set ISBT Concatenation to Autodiscriminate use this parameter to set the number of times the digital imager scanner must decode an ISBT symbol before determining that there is no additional symbol Scan the bar code below then scan two numeric bar codes in Appendix D Numeric Bar Codes to set a value between 2 and 20 Enter a leading zero for single d...

Страница 203: ... Code 39 is a variant of Code 39 used in the marking of computer tape cartridges Trioptic Code 39 symbols always contain six characters To enable or disable Trioptic Code 39 scan the appropriate bar code below Enable Code 39 01h Disable Code 39 00h Enable Trioptic Code 39 01h Disable Trioptic Code 39 00h NOTE You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously ...

Страница 204: ...e converting Code 39 to Code 32 Code 32 Prefix Parameter E7h Scan the appropriate bar code below to enable or disable adding the prefix character A to all Code 32 bar codes NOTE Code 39 must be enabled for this parameter to function Enable Convert Code 39 to Code 32 01h Disable Convert Code 39 to Code 32 00h NOTE Convert Code 39 to Code 32 must be enabled for this parameter to function Enable Code...

Страница 205: ...g either of two selected lengths Select lengths using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only those Code 39 symbols containing either 2 or 14 characters select Code 39 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or change the selection scan Cancel on page D 2 Length Within Range Select this option to decode a Code 39 symbol with a sp...

Страница 206: ...o check the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm Only Code 39 symbols which include a modulo 43 check digit are decoded so only enable this if the Code 39 symbols contain a Modulo 43 check digit Code 39 Length Within Range Code 39 Any Length Enable Code 39 Check Digit 01h Disable Code 39 Check Digit 00h ...

Страница 207: ...scan the appropriate bar code below Transmit Code 39 Check Digit Enable 01h Do Not Transmit Code 39 Check Digit Disable 00h NOTE Code 39 Check Digit Verification must be enabled for this parameter to function Enable Code 39 Full ASCII 01h Disable Code 39 Full ASCII 00h NOTE You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously Code 39 Full ASCII to Full ASCII Correlation is host...

Страница 208: ...selecting Buffer Code 39 Motorola recommends configuring the digital imager scanner to decode Code 39 symbology only While there is data in the transmission buffer you cannot select Do Not Buffer Code 39 The buffer holds 200 bytes of information To disable Code 39 buffering when there is data in the transmission buffer first force the buffer transmission see Transmit Buffer on page 10 39 or clear ...

Страница 209: ... imager scanner transmits and clears the buffer The digital imager scanner issues a Low High beep 3 Scan a Code 39 bar code with a leading character other than a space The digital imager scanner appends new decode data to buffered data The digital imager scanner transmits and clears the buffer The digital imager scanner signals that the buffer transmitted with a low high beep The digital imager sc...

Страница 210: ...ssion buffer The digital imager scanner indicates that it rejected the symbol by issuing three long high beeps No transmission occurs The data in the buffer is not affected Attempt to Transmit an Empty Buffer If the symbol just read was the Transmit Buffer symbol and the Code 39 buffer is empty A short low high low beep signals that the buffer is empty No transmission occurs The buffer remains emp...

Страница 211: ... Lengths Select this option to decode only Code 93 symbols containing either of two selected lengths Select lengths using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only Code 93 symbols containing either 2 or 14 characters select Code 93 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Cancel on page D 2 Length Wit...

Страница 212: ...0 42 Symbol DS6707 Digital Imager Scanner Product Reference Guide Set Lengths for Code 93 continued Code 93 One Discrete Length Code 93 Two Discrete Lengths Code 93 Length Within Range Code 93 Any Length ...

Страница 213: ...s Select this option to decode only Code 11 symbols containing either of two selected lengths Select lengths using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only those Code 11 symbols containing either 2 or 14 characters select Code 11 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Cancel on page D 2 Length With...

Страница 214: ...0 44 Symbol DS6707 Digital Imager Scanner Product Reference Guide Set Lengths for Code 11 continued Code 11 One Discrete Length Code 11 Two Discrete Lengths Code 11 Length Within Range Code 11 Any Length ...

Страница 215: ...cified check digit algorithm This selects the check digit mechanism for the decoded Code 11 bar code The options are to check for one check digit check for two check digits or disable the feature To enable this feature scan the bar code below corresponding to the number of check digits encoded in the Code 11 symbols Disable 00h One Check Digit 01h Two Check Digits 02h ...

Страница 216: ... 11 Check Digits Parameter 2Fh This feature selects whether or not to transmit the Code 11 check digit s Transmit Code 11 Check Digit s Enable 01h Do Not Transmit Code 11 Check Digit s Disable 00h NOTE Code 11 Check Digit Verification must be enabled for this parameter to function ...

Страница 217: ...using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only those I 2 of 5 symbols containing either 2 or 14 characters select I 2 of 5 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Cancel on page D 2 Length Within Range Select this option to decode an I 2 of 5 symbol with a specific length range Select lengths using ...

Страница 218: ...8 Symbol DS6707 Digital Imager Scanner Product Reference Guide Set Lengths for Interleaved 2 of 5 I 2 of 5 One Discrete Length I 2 of 5 Two Discrete Lengths I 2 of 5 Length Within Range I 2 of 5 Any Length ...

Страница 219: ... Uniform Symbology Specification USS or the Optical Product Code Council OPCC check digit algorithm Transmit I 2 of 5 Check Digit Parameter 2Ch Scan the appropriate bar code below to transmit I 2 of 5 data with or without the check digit Disable 00h USS Check Digit 01h OPCC Check Digit 02h Transmit I 2 of 5 Check Digit Enable 01h Do Not Transmit I 2 of 5 Check Digit Disable 00h ...

Страница 220: ...nable this parameter to convert 14 character I 2 of 5 codes to EAN 13 and transmit to the host as EAN 13 To accomplish this the I 2 of 5 code must be enabled and the code must have a leading zero and a valid EAN 13 check digit Convert I 2 of 5 to EAN 13 Enable 01h Do Not Convert I 2 of 5 to EAN 13 Disable 00h ...

Страница 221: ...umeric Bar Codes For example to decode only those D 2 of 5 symbols containing either 2 or 14 characters select D 2 of 5 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Cancel on page D 2 Length Within Range Select this option to decode a D 2 of 5 symbol with a specific length range Select lengths using numeric bar codes in Appendix D Numeric Bar ...

Страница 222: ...ymbol DS6707 Digital Imager Scanner Product Reference Guide Set Lengths for Discrete 2 of 5 continued D 2 of 5 One Discrete Length D 2 of 5 Two Discrete Lengths D 2 of 5 Length Within Range D 2 of 5 Any Length ...

Страница 223: ...gths Select this option to decode only Codabar symbols containing either of two selected lengths Select lengths using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only Codabar symbols containing either 2 or 14 characters select Codabar Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Cancel on page D 2 Length Within ...

Страница 224: ...0 54 Symbol DS6707 Digital Imager Scanner Product Reference Guide Set Lengths for Codabar continued Codabar One Discrete Length Codabar Two Discrete Lengths Codabar Length Within Range Codabar Any Length ...

Страница 225: ...le this feature if the host system requires this data format NOTIS Editing Parameter 37h Enable this to strip the start and stop characters from a decoded Codabar symbol Enable this feature if the host system requires this data format NOTE Symbol length does not include start and stop characters Enable CLSI Editing 01h Disable CLSI Editing 00h Enable NOTIS Editing 01h Disable NOTIS Editing 00h ...

Страница 226: ...meric bar codes in Appendix D Numeric Bar Codes For example to decode only MSI symbols containing either 2 or 14 characters select MSI Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Cancel on page D 2 Length Within Range Select this option to decode a MSI symbol within a specific length range Select lengths using numeric bar codes in Appendix D ...

Страница 227: ...k digit is optional If the MSI codes include two check digits scan the Two MSI Check Digits bar code to enable verification of the second check digit See MSI Check Digit Algorithm on page 10 58 for the selection of second digit algorithms MSI One Discrete Length MSI Two Discrete Lengths MSI Length Within Range MSI Any Length One MSI Check Digit 00h Two MSI Check Digits 01h ...

Страница 228: ...a with or without the check digit MSI Check Digit Algorithm Parameter 33h Two algorithms are possible for verifying the second MSI check digit Select the bar code below corresponding to the algorithm used to encode the check digit Transmit MSI Check Digit s Enable 01h Do Not Transmit MSI Check Digit s Disable 00h MOD 10 MOD 11 00h MOD 10 MOD 10 01h ...

Страница 229: ...mbologies 10 59 Chinese 2 of 5 Enable Disable Chinese 2 of 5 Parameter F0h 98h To enable or disable Chinese 2 of 5 scan the appropriate bar code below Enable Chinese 2 of 5 01h Disable Chinese 2 of 5 00h ...

Страница 230: ...tal Imager Scanner Product Reference Guide Matrix 2 of 5 Enable Disable Matrix 2 of 5 Parameter F1h 6Ah To enable or disable Matrix 2 of 5 scan the appropriate bar code below Enable Matrix 2 of 5 01h Disable Matrix 2 of 5 00h ...

Страница 231: ...Select lengths using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only Matrix 2 of 5 symbols containing either 2 or 14 characters select Matrix 2 of 5 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Numeric Bar Codes on page D 1 Length Within Range Select this option to decode a Matrix 2 of 5 symbol with a specific ...

Страница 232: ...an the appropriate bar code below to transmit the bar code data with or without the Matrix 2 of 5 check digit Transmit Matrix 2 of 5 Check Digit Parameter F1h 6Fh Scan a bar code below to transmit Matrix 2 of 5 data with or without the check digit Enable Matrix 2 of 5 Check Digit 01h Disable Matrix 2 of 5 Check Digit 00h Transmit Matrix 2 of 5 Check Digit 01h Do Not Transmit Matrix 2 of 5 Check Di...

Страница 233: ...n 3 of 5 Enable Disable Korean 3 of 5 Parameter F1h 45h To enable or disable Korean 3 of 5 scan the appropriate bar code below NOTE The length for Korean 3 of 5 is fixed at 6 Enable Korean 3 of 5 01h Disable Korean 3 of 5 00h ...

Страница 234: ...ly the scanner decodes regular 1D bar codes only Inverse Only the scanner decodes inverse 1D bar codes only Inverse Autodetect the scanner decodes both regular and inverse 1D bar codes NOTE The default for this option varies by scanner model as follows DS6707 SR DS6707 DC Regular DS6707 DP DS6707 HD Inverse Autodetect Regular 00h Inverse Only 01h Inverse Autodetect 02h ...

Страница 235: ...r 59h To enable or disable US Postnet scan the appropriate bar code below US Planet Parameter 5Ah To enable or disable US Planet scan the appropriate bar code below Enable US Postnet 01h Disable US Postnet 00h Enable US Planet 01h Disable US Planet 00h ...

Страница 236: ...hether to transmit US Postal data which includes both US Postnet and US Planet with or without the check digit UK Postal Parameter 5Bh To enable or disable UK Postal scan the appropriate bar code below Transmit US Postal Check Digit 01h Do Not Transmit US Postal Check Digit 00h Enable UK Postal 01h Disable UK Postal 00h ...

Страница 237: ...transmit UK Postal data with or without the check digit Japan Postal Parameter F0h 22h To enable or disable Japan Postal scan the appropriate bar code below Transmit UK Postal Check Digit 01h Do Not Transmit UK Postal Check Digit 00h Enable Japan Postal 01h Disable Japan Postal 00h ...

Страница 238: ...07 Digital Imager Scanner Product Reference Guide Australian Postal Parameter F0h 23h To enable or disable Australian Postal scan the appropriate bar code below Enable Australian Postal 01h Disable Australian Postal 00h ...

Страница 239: ...meric Encoding Decode the Customer Information Field using the C Encoding Table Numeric Encoding Decode the Customer Information Field using the N Encoding Table For more information on Australia Post Encoding Tables refer to the Australia Post Customer Barcoding Technical Specifications available at http www auspost com au NOTE This option increases the risk of misdecodes because the encoded data...

Страница 240: ... Code scan the appropriate bar code below USPS 4CB One Code Intelligent Mail Parameter F1h 50h To enable or disable USPS 4CB One Code Intelligent Mail scan the appropriate bar code below Enable Netherlands KIX Code 01h Disable Netherlands KIX Code 00h Enable USPS 4CB One Code Intelligent Mail 01h Disable USPS 4CB One Code Intelligent Mail 00h ...

Страница 241: ...Symbologies 10 71 UPU FICS Postal Parameter F1h 63h To enable or disable UPU FICS Postal scan the appropriate bar code below Enable UPU FICS Postal 01h Disable UPU FICS Postal 00h ...

Страница 242: ...ons have stacked variants Scan the appropriate bar codes to enable or disable each variant of GS1 DataBar GS1 DataBar 14 Parameter F0h 52h GS1 DataBar Limited Parameter F0h 53h NOTE For increased decoding security scanners with later firmware versions do not support decoding inverse video GS1 DataBar bar codes Enable GS1 DataBar 14 01h Disable GS1 DataBar 14 00h Enable GS1 DataBar Limited 01h Disa...

Страница 243: ... the first digit and report the bar code as EAN 13 For bar codes beginning with two or more zeros but not six zeros this parameter strips the leading 0100 and reports the bar code as UPC A The UPC A Preamble parameter that transmits the system character and country code applies to converted bar codes Note that neither the system character nor the check digit can be stripped Enable GS1 DataBar Expa...

Страница 244: ...ite CC C Parameter F0h 55h Scan a bar code below to enable or disable Composite bar codes of type CC C Composite CC A B Parameter F0h 56h Scan a bar code below to enable or disable Composite bar codes of type CC A B Enable CC C 01h Disable CC C 00h Enable CC A B 01h Disable CC A B 00h ...

Страница 245: ...Symbologies 10 75 Composite TLC 39 Parameter F0h 73h Scan a bar code below to enable or disable Composite bar codes of type TLC 39 Enable TLC39 01h Disable TLC39 00h ...

Страница 246: ... Linked to transmit UPC bar codes regardless of whether a 2D symbol is detected Select UPC Always Linked to transmit UPC bar codes and the 2D portion If 2D is not present the UPC bar code does not transmit If you select Autodiscriminate UPC Composites the scanner determines if there is a 2D portion then transmits the UPC as well as the 2D portion if present UPC Never Linked 00h UPC Always Linked 0...

Страница 247: ...bar code GS1 128 Emulation Mode for UCC EAN Composite Codes Parameter F0h ABh Select whether to enable or disable this mode Single Beep after both are decoded 00h Beep as each code type is decoded 01h Double Beep after both are decoded 02h Enable GS1 128 Emulation Mode for UCC EAN Composite Codes 01h Disable GS1 128 Emulation Mode for UCC EAN Composite Codes 00h ...

Страница 248: ...e Disable PDF417 Parameter 0Fh To enable or disable PDF417 scan the appropriate bar code below Enable Disable MicroPDF417 Parameter E3h To enable or disable MicroPDF417 scan the appropriate bar code below Enable PDF417 01h Disable PDF417 00h Enable MicroPDF417 01h Disable MicroPDF417 00h ...

Страница 249: ...lowing prefixes C1 if the first codeword is 903 905 C2 if the first codeword is 908 or 909 C0 if the first codeword is 910 or 911 Disable this to transmit them with one of the following prefixes L3 if the first codeword is 903 905 L4 if the first codeword is 908 or 909 L5 if the first codeword is 910 or 911 Scan a bar code below to enable or disable Code 128 Emulation NOTE Linked MicroPDF codeword...

Страница 250: ... Symbol DS6707 Digital Imager Scanner Product Reference Guide Data Matrix Parameter F0h 24h To enable or disable Data Matrix scan the appropriate bar code below Enable Data Matrix 01h Disable Data Matrix 00h ...

Страница 251: ...r Data Matrix bar codes only Inverse Only the scanner decodes inverse Data Matrix bar codes only Inverse Autodetect the scanner decodes both regular and inverse Data Matrix bar codes NOTE The default for this option varies by scanner model as follows DS6707 SR DS6707 DC Regular DS6707 DP DS6707 HD Inverse Autodetect Regular 00h Inverse Only 01h Inverse Autodetect 02h ...

Страница 252: ...de Maxicode Parameter F0h 26h To enable or disable Maxicode scan the appropriate bar code below QR Code Parameter F0h 25h To enable or disable QR Code scan the appropriate bar code below Enable Maxicode 01h Disable Maxicode 00h Enable QR Code 01h Disable QR Code 00h ...

Страница 253: ...gular QR bar codes only Inverse Only the scanner decodes inverse QR bar codes only Inverse Autodetect the scanner decodes both regular and inverse QR bar codes NOTE The default for this option varies by scanner model as follows DS6707 SR DS6707 DC Regular DS6707 DP DS6707 HD Inverse Autodetect Regular 00h Inverse Only 01h Inverse Autodetect 02h ...

Страница 254: ...ce Guide MicroQR Parameter F1h 3Dh To enable or disable MicroQR scan the appropriate bar code below Aztec Parameter F1h 3Eh To enable or disable Aztec scan the appropriate bar code below Enable MicroQR 01h Disable MicroQR 00h Enable Aztec 01h Disable Aztec 00h ...

Страница 255: ...ular Aztec bar codes only Inverse Only the scanner decodes inverse Aztec bar codes only Inverse Autodetect the scanner decodes both regular and inverse Aztec bar codes NOTE The default for this option varies by scanner model as follows DS6707 SR DS6707 DC Regular DS6707 DP DS6707 HD Inverse Autodetect Regular 00h Inverse Only 01h Inverse Autodetect 02h ...

Страница 256: ...g decoded Redundancy Level 2 The following code types must be successfully read twice before being decoded Redundancy Level 3 Code types other than the following must be successfully read twice before being decoded The following codes must be read three times Table 10 2 Redundancy Level 1 Codes Code Type Code Length Codabar 8 characters or less MSI 4 characters or less D 2 of 5 8 characters or les...

Страница 257: ...ncy Level 4 The following code types must be successfully read three times before being decoded Table 10 5 Redundancy Level 4 Codes Code Type Code Length All All Redundancy Level 1 01h Redundancy Level 2 02h Redundancy Level 3 03h Redundancy Level 4 04h ...

Страница 258: ...r to operate in its most aggressive state while providing sufficient security in decoding most in spec bar codes Security Level 1 This default setting eliminates most misdecodes Security Level 2 Select this option if Security level 1 fails to eliminate misdecodes Security Level 3 If you selected Security Level 2 and misdecodes still occur select this security level Be advised selecting this option...

Страница 259: ...can grow larger than the maximum size allowed preventing the digital imager scanner from decoding the symbol If this problem occurs scan Large Intercharacter Gaps to tolerate these out of specification bar codes Report Version Scan the bar code below to report the version of software installed in the digital imager scanner Normal Intercharacter Gaps 06h Large Intercharacter Gaps 0Ah Report Softwar...

Страница 260: ...ce and aborts from Macro PDF mode Abort Macro PDF Entry This clears all currently stored Macro PDF data in the buffer without transmission and aborts from Macro PDF mode CAUTION When printing keep each Macro PDF sequence separate as each sequence has unique identifiers Do not mix bar codes from several Macro PDF sequences even if they encode the same data When scanning Macro PDF sequences scan the...

Страница 261: ...s of length 252 or less depending on the host selected and applies the rule to each segment Rules Criteria Linked to Actions ADF uses rules to customize data These rules perform detailed actions when the data meets certain criteria One rule may consist of single or multiple criteria applied to single or multiple actions For instance a data formatting rule could be Criteria When scan data is Code 3...

Страница 262: ... 11 9 Beeper Definitions on page 2 2 guide through the programming steps ADF Bar Code Menu Example This section provides an example of how to enter ADF rules for scan data An auto parts distribution center wants to encode manufacturer ID part number and destination code into their own Code 128 bar codes The distribution center also has products that carry UPC bar codes placed there by the manufact...

Страница 263: ... 50 High High 5 Save Rule 11 8 High Low High Low To correct any errors made while entering this rule scan the Quit Entering Rules bar code on page 11 9 If you already saved the rule scan the Erase Previously Saved Rule bar code on page 11 9 Alternate Rule Sets Group ADF rules into one of four alternate sets which you can turn on and off when needed This is useful to format the same message in diff...

Страница 264: ...h 15 send the next 2 characters send the class key send the next 8 characters send the stock key turn off rule set 1 For optimal results scan the Disable All Rule Sets bar code on page 11 10 after programming a rule belonging to an alternate rule set In addition to enabling and disabling rule sets within the rules enable or disable them by scanning the appropriate bar codes on page 11 10 Rules Hie...

Страница 265: ...rammable rules first then the default rules Disable default rules by entering the following general rule in the user programmable buffer When receiving scan data send all data Since this rule always applies ADF never enters the default rules ADF Bar Codes Table 11 1 lists the bar codes available through ADF Table 11 1 ADF Bar Codes Parameter Page Number Special Commands 11 8 Pause Duration 11 8 Be...

Страница 266: ... Field s 11 31 Move Cursor 11 32 Send Pause 11 33 Skip Ahead 11 34 Skip Back 11 35 Send Preset Value 11 37 Modify Data 11 38 Remove All Spaces 11 38 Crunch All Spaces 11 38 Stop Space Removal 11 38 Remove Leading Zeros 11 38 Stop Zero Removal 11 38 Pad Data with Spaces 11 39 Pad Data with Zeros 11 43 Beeps 11 48 Send Keystroke Control Characters and Keyboard Characters 11 48 Keyboard Characters 11...

Страница 267: ...ight Control Key 11 85 Send Graphic User Interface GUI Characters 11 86 Send GUI 0 Send GUI 9 11 86 Send GUI A Send GUI Z 11 87 Turn On Off Rule Sets 11 91 Alphanumeric Keyboard 11 93 Space 11 93 0 9 11 97 A Z 11 98 Cancel 11 102 End of Message 11 102 a z 11 102 11 106 Table 11 1 ADF Bar Codes Continued Parameter Page Number ...

Страница 268: ...o bar codes representing a 0 1 second interval in the range of 0 1 to 9 9 For example scan bar codes 0 and 1 to insert a 0 1 second pause 0 and 5 to insert a 0 5 second delay The default is 1 second See Appendix D Numeric Bar Codes To correct an error or change a selection scan Cancel on page D 2 Pause Duration Begin New Rule Scan the bar code below to start entering a new rule Begin New Rule Save...

Страница 269: ...these bar codes to erase criteria actions or rules Quit Entering Rules Scan the bar code below to quit entering rules Quit Entering Rules Erase Criteria And Start Again Erase Actions And Start Again Erase Previously Saved Rule Erase All Rules ...

Страница 270: ...ol DS6707 Digital Imager Scanner Product Reference Guide Disable Rule Set Use these bar codes to disable rule sets Disable Rule Set 1 Disable Rule Set 2 Disable Rule Set 3 Disable Rule Set 4 Disable All Rule Sets ...

Страница 271: ...ect all code types to be affected by the rule Scan all selected codes in succession before selecting other criteria To select all code types do not scan any code type Code 39 Codabar GS1 DataBar 14 GS1 DataBar Limited GS1 DataBar Expanded Code 128 D 2 OF 5 ...

Страница 272: ...11 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Types continued IATA 2 OF 5 I 2 OF 5 Code 93 UPC A UPC E EAN 8 EAN 13 ISSN ...

Страница 273: ...Advanced Data Formatting 11 13 Code Types continued MSI GS1 128 UPC E1 Bookland EAN Trioptic Code 39 Code 11 Code 32 ...

Страница 274: ...11 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Types continued ISBT 128 Coupon Code Chinese 2 of 5 Matrix 2 of 5 Korean 3 of 5 US Postnet US Planet ...

Страница 275: ...Advanced Data Formatting 11 15 UK Postal ...

Страница 276: ... 16 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Types continued Japan Postal Australian Postal Netherlands KIX Code USPS 4CB One Code Intelligent Mail UPU FICS Postal PDF417 MicroPDF ...

Страница 277: ...Advanced Data Formatting 11 17 Code Types continued Macro PDF Macro MicroPDF MaxiCode Data Matrix QR Code MicroQR TLC 39 ...

Страница 278: ...eference Guide Code Types continued UPC EAN Composites GS1 DataBar and GS1 128 Composites Aztec Aztec Rune NOTE When selecting composite bar codes enable AIM IDs if parsing UPC or EAN composite data or data from an application that uses symbol separators ...

Страница 279: ... bar codes to define the number of characters the selected code type must contain Select one length per rule only Do not select any code length to select code types of any length 1 Character 2 Characters 3 Characters 4 Characters 5 Characters 6 Characters ...

Страница 280: ...11 20 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Lengths continued 7 Characters 8 Characters 9 Characters 10 Characters 11 Characters 12 Characters 13 Characters ...

Страница 281: ...Advanced Data Formatting 11 21 Code Lengths continued 14 Characters 15 Characters 16 Characters 17 Characters 18 Characters 19 Characters 20 Characters ...

Страница 282: ...11 22 Symbol DS6707 Digital Imager Scanner Product Reference Guide Code Lengths continued 21 Characters 22 Characters 23 Characters 24 Characters 25 Characters 26 Characters 27 Characters ...

Страница 283: ...5 features Specific String at Start Specific String Any Location Specific String Search Any Message OK Rule Belongs to Set Specific String at Start 1 Scan the following bar code 2 Scan the bar codes representing the desired character or characters up to a total of 8 using the Alphanumeric Keyboard on page 11 93 3 Scan End of Message bar code on page 11 102 Specific String At Start Code Lengths con...

Страница 284: ...acter or characters up to a total of 8 using the Alphanumeric Keyboard on page 11 93 4 Scan End of Message bar code on page 11 102 Specific String Any Location Specific String Search 1 Scan the following bar code 2 Scan the bar codes representing the desired character or characters up to a total of 10 using the Alphanumeric Keyboard on page 11 93 3 Scan End of Message bar code on page 11 102 Any M...

Страница 285: ...Advanced Data Formatting 11 25 Numeric Keypad Do not confuse bar codes on this page with those on the alphanumeric keyboard 0 1 2 3 4 5 6 ...

Страница 286: ...11 26 Symbol DS6707 Digital Imager Scanner Product Reference Guide Numeric Keypad continued 7 8 9 Cancel ...

Страница 287: ...s To Set Select the set to which a rule belongs There are four possible rule sets See Alternate Rule Sets on page 11 3 for more information about rule sets Rule Belongs To Set 1 Rule Belongs To Set 2 Rule Belongs To Set 3 Rule Belongs To Set 4 ...

Страница 288: ...umeric Keyboard on page 11 93 or send the next X characters Note that only bar codes for Send Next 1 to 20 appear here and can be scanned multiple times to send values greater then 20 For instance to send the next 28 characters scan Send Next 20 Characters then Send Next 8 Characters Send Data Up To Character Send All Data That Remains Send Next Character Send Next 2 Characters Send Next 3 Charact...

Страница 289: ...ed Data Formatting 11 29 Send Data continued Send Next 5 Characters Send Next 6 Characters Send Next 7 Characters Send Next 8 Characters Send Next 9 Characters Send Next 10 Characters Send Next 11 Characters ...

Страница 290: ...l Imager Scanner Product Reference Guide Send Data continued Send Next 12 Characters Send Next 13 Characters Send Next 14 Characters Send Next 15 Characters Send Next 16 Characters Send Next 17 Characters Send Next 18 Characters ...

Страница 291: ...can Move Cursor Past Character then select a character from the Alphanumeric Keyboard If the character is not there the cursor does not move i e has no effect 11 33 Move Cursor Past a Specific String This action moves the cursor past the first occurrence of a selected string Scan Move Cursor Past Specific String then select the character s up to 10 using the Alphanumeric Keyboard Scan the End of M...

Страница 292: ...on page 11 102 Enter another alphanumeric string representing the character s up to 10 to insert using the Alphanumeric Keyboard Scan End of Message 11 33 Skip to End Scan Skip to End to move cursor to the end of the data 11 33 Skip Ahead N Characters Scan one of these bar codes to select the number of positions ahead to move the cursor 11 34 Skip Back N Characters Scan one of these bar codes to s...

Страница 293: ...he transmission of data Pause Duration on page 11 8 controls the length of this pause Move Cursor continued Move Cursor Past Character Move Cursor Past Specific String Move Cursor to Specific String and Replace Move Cursor to Last Occurrence of String and Replace All Skip to End Send Pause ...

Страница 294: ...ct Reference Guide Skip Ahead Use the following bar codes to skip ahead characters Skip Ahead 1 Character Skip Ahead 2 Characters Skip Ahead 3 Characters Skip Ahead 4 Characters Skip Ahead 5 Characters Skip Ahead 6 Characters Skip Ahead 7 Characters ...

Страница 295: ...1 35 Skip Back Use the following bar codes to skip back characters Skip Ahead continued Skip Ahead 8 Characters Skip Ahead 9 Characters Skip Ahead 10 Characters Skip Back 1 Character Skip Back 2 Characters Skip Back 3 Characters ...

Страница 296: ...ital Imager Scanner Product Reference Guide Skip Back continued Skip Back 4 Characters Skip Back 5 Characters Skip Back 6 Characters Skip Back 7 Characters Skip Back 8 Characters Skip Back 9 Characters Skip Back 10 Characters ...

Страница 297: ...Advanced Data Formatting 11 37 Send Preset Value Use these bar codes to send preset values Set these values using the Scan Prefix and Scan Suffix bar codes on page 4 21 Send Prefix Send Suffix ...

Страница 298: ...apply to the Send Keystroke or Send Preset Value options Remove All Spaces To remove all spaces in the send commands that follow scan the bar code below Remove All Spaces Crunch All Spaces To leave one space between words scan the bar code below This also removes all leading and trailing spaces Crunch All Spaces Stop Space Removal Scan the bar code below to disable space removal Stop Space Removal...

Страница 299: ...o the left scan the bar code containing the desired number of spaces Send commands activate this parameter Pad Spaces To Length 1 Pad Spaces To Length 2 Pad Spaces To Length 3 Pad Spaces To Length 4 Pad Spaces To Length 5 Pad Spaces To Length 6 Pad Spaces To Length 7 ...

Страница 300: ...ger Scanner Product Reference Guide Pad Data with Spaces continued Pad Spaces To Length 8 Pad Spaces To Length 9 Pad Spaces To Length 10 Pad Spaces To Length 11 Pad Spaces To Length 12 Pad Spaces To Length 13 Pad Spaces To Length 14 ...

Страница 301: ...Formatting 11 41 Pad Data with Spaces continued Pad Spaces To Length 15 Pad Spaces To Length 16 Pad Spaces To Length 17 Pad Spaces To Length 18 Pad Spaces To Length 19 Pad Spaces To Length 20 Pad Spaces To Length 21 ...

Страница 302: ...er Scanner Product Reference Guide Pad Data with Spaces continued Pad Spaces To Length 22 Pad Spaces To Length 23 Pad Spaces To Length 24 Pad Spaces To Length 25 Pad Spaces To Length 26 Pad Spaces To Length 27 Pad Spaces To Length 28 ...

Страница 303: ...o the left scan the bar code containing the desired number of zeros Send commands activate this parameter Pad Data with Spaces continued Pad Spaces To Length 29 Pad Spaces To Length 30 Stop Pad Spaces Pad Zeros To Length 1 Pad Zeros To Length 2 Pad Zeros To Length 3 ...

Страница 304: ...al Imager Scanner Product Reference Guide Pad Data with Zeros continued Pad Zeros To Length 4 Pad Zeros To Length 5 Pad Zeros To Length 6 Pad Zeros To Length 7 Pad Zeros To Length 8 Pad Zeros To Length 9 Pad Zeros To Length 10 ...

Страница 305: ...ata Formatting 11 45 Pad Data with Zeros continued Pad Zeros To Length 11 Pad Zeros To Length 12 Pad Zeros To Length 13 Pad Zeros To Length 14 Pad Zeros To Length 15 Pad Zeros To Length 16 Pad Zeros To Length 17 ...

Страница 306: ...Imager Scanner Product Reference Guide Pad Data with Zeros continued Pad Zeros To Length 18 Pad Zeros To Length 19 Pad Zeros To Length 20 Pad Zeros To Length 21 Pad Zeros To Length 22 Pad Zeros To Length 23 Pad Zeros To Length 24 ...

Страница 307: ...ed Data Formatting 11 47 Pad Data with Zeros continued Pad Zeros To Length 25 Pad Zeros To Length 26 Pad Zeros To Length 27 Pad Zeros To Length 28 Pad Zeros To Length 29 Pad Zeros To Length 30 Stop Pad Zeros ...

Страница 308: ...e Guide Beeps Select a beep sequence for each ADF rule Send Keystroke Control Characters and Keyboard Characters Control Characters Scan a Send bar code for the keystroke to send Beep Once Beep Twice Beep Three Times Send Control 2 Send Control A Send Control B ...

Страница 309: ...Advanced Data Formatting 11 49 Control Characters continued Send Control C Send Control D Send Control E Send Control F Send Control G Send Control H Send Control I ...

Страница 310: ...11 50 Symbol DS6707 Digital Imager Scanner Product Reference Guide Control Characters continued Send Control J Send Control K Send Control L Send Control M Send Control N Send Control O Send Control P ...

Страница 311: ...Advanced Data Formatting 11 51 Control Characters continued Send Control Q Send Control R Send Control S Send Control T Send Control U Send Control V Send Control W ...

Страница 312: ...11 52 Symbol DS6707 Digital Imager Scanner Product Reference Guide Control Characters continued Send Control X Send Control Y Send Control Z Send Control Send Control Send Control ...

Страница 313: ...Advanced Data Formatting 11 53 Keyboard Characters Scan a Send bar code for the keyboard characters to send Control Characters continued Send Control 6 Send Control Send Space Send Send Send ...

Страница 314: ...11 54 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters continued Send Send Send Send Send Send Send ...

Страница 315: ...Advanced Data Formatting 11 55 Keyboard Characters continued Send Send Send Send Send Send 0 Send 1 ...

Страница 316: ...11 56 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters continued Send 2 Send 3 Send 4 Send 5 Send 6 Send 7 Send 8 ...

Страница 317: ...Advanced Data Formatting 11 57 Keyboard Characters continued Send 9 Send Send Send Send Send Send ...

Страница 318: ...11 58 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters continued Send Send A Send B Send C Send D Send E Send F ...

Страница 319: ...Advanced Data Formatting 11 59 Keyboard Characters continued Send G Send H Send I Send J Send K Send L Send M ...

Страница 320: ...11 60 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters continued Send N Send O Send P Send Q Send R Send S Send T ...

Страница 321: ...Advanced Data Formatting 11 61 Keyboard Characters continued Send U Send V Send W Send X Send Y Send Z Send ...

Страница 322: ...11 62 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters continued Send Send Send Send _ Send Send a Send b ...

Страница 323: ...Advanced Data Formatting 11 63 Keyboard Characters continued Send c Send d Send e Send f Send g Send h Send i ...

Страница 324: ...11 64 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters continued Send j Send k Send l Send m Send n Send o Send p ...

Страница 325: ...Advanced Data Formatting 11 65 Keyboard Characters continued Send q Send r Send s Send t Send u Send v Send w ...

Страница 326: ...11 66 Symbol DS6707 Digital Imager Scanner Product Reference Guide Keyboard Characters continued Send x Send y Send z Send Send Send Send ...

Страница 327: ...Advanced Data Formatting 11 67 Send ALT Characters Send Alt 2 Send Alt Send Alt A Send Alt B Send Alt C Send Alt D Send Alt E ...

Страница 328: ...11 68 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Alt F ...

Страница 329: ...Advanced Data Formatting 11 69 Send ALT Characters continued Send Alt G Send Alt H Send Alt I Send Alt J Send Alt K Send Alt L Send Alt M ...

Страница 330: ...11 70 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send ALT Characters continued Send Alt N Send Alt O Send Alt P Send Alt Q Send Alt R Send Alt S Send Alt T ...

Страница 331: ...Advanced Data Formatting 11 71 Send ALT Characters continued Send Alt U Send Alt V Send Alt W Send Alt X Send Alt Y Send Alt Z Send Alt ...

Страница 332: ...11 72 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send ALT Characters continued Send Alt Send Alt ...

Страница 333: ...Advanced Data Formatting 11 73 Send Keypad Characters Send Keypad Send Keypad Send Keypad Send Keypad Send Keypad Send Keypad 0 Send Keypad 1 ...

Страница 334: ...11 74 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Keypad Characters continued Send Keypad 2 Send Keypad 3 Send Keypad 4 Send Keypad 5 Send Keypad 6 Send Keypad 7 Send Keypad 8 ...

Страница 335: ...Advanced Data Formatting 11 75 Send Keypad Characters continued Send Keypad 9 Send Keypad Enter Send Keypad Numlock Send Break Key Send Delete Key Send Page Up Key Send End Key ...

Страница 336: ...l DS6707 Digital Imager Scanner Product Reference Guide Send Keypad Characters continued Send Page Down Key Send Pause Key Send Scroll Lock Key Send Backspace Key Send Tab Key Send Print Screen Key Send Insert Key ...

Страница 337: ...Advanced Data Formatting 11 77 Send Keypad Characters continued Send Home Key Send Enter Key Send Escape Key Send Up Arrow Key Send Down Arrow Key Send Left Arrow Key Send Right Arrow Key ...

Страница 338: ...11 78 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Function Key Send F1 Key Send F2 Key Send F3 Key Send F4 Key Send F5 Key Send F6 Key Send F7 Key ...

Страница 339: ...Advanced Data Formatting 11 79 Send Function Key continued Send F8 Key Send F9 Key Send F10 Key Send F11 Key Send F12 Key Send F13 Key Send F14 Key ...

Страница 340: ...11 80 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Function Key continued Send F15 Key Send F16 Key Send F17 Key Send F18 Key Send F19 Key Send F20 Key Send F21 Key ...

Страница 341: ...Advanced Data Formatting 11 81 Send Function Key continued Send F22 Key Send F23 Key Send F24 Key Send PF1 Key Send PF2 Key Send PF3 Key Send PF4 Key ...

Страница 342: ...11 82 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Function Key continued Send PF5 Key Send PF6 Key Send PF7 Key Send PF8 Key Send PF9 Key Send PF10 Key Send PF11 Key ...

Страница 343: ...Advanced Data Formatting 11 83 Send Function Key continued Send PF12 Key Send PF13 Key Send PF14 Key Send PF15 Key Send PF16 Key Send PF17 Key Send PF18 Key ...

Страница 344: ...11 84 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Function Key continued Send PF19 Key Send PF20 Key Send PF21 Key Send PF22 Key Send PF23 Key Send PF24 Key Send PF25 Key ...

Страница 345: ...nd Right Control Key The Send Right Control Key action will send a tap press and release of the Right Control Key Send Right Control Key Send Function Key continued Send PF26 Key Send PF27 Key Send PF28 Key Send PF29 Key Send PF30 Key ...

Страница 346: ...UI Characters The Send Graphic User Interface Character actions tap the specified key while holding the System Dependent Graphic User Interface GUI key The definition of the Graphic User Interface key depends on the attached system Send GUI 0 Send GUI 1 Send GUI 2 Send GUI 3 Send GUI 4 Send GUI 5 ...

Страница 347: ...Advanced Data Formatting 11 87 Send Graphic User Interface GUI Characters continued Send GUI 6 Send GUI 7 Send GUI 8 Send GUI 9 Send GUI A Send GUI B Send GUI C ...

Страница 348: ...11 88 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Graphic User Interface GUI Characters continued Send GUI D Send GUI E Send GUI F Send GUI G Send GUI H Send GUI I Send GUI J ...

Страница 349: ...Advanced Data Formatting 11 89 Send Graphic User Interface GUI Characters continued Send GUI K Send GUI L Send GUI M Send GUI N Send GUI O Send GUI P Send GUI Q ...

Страница 350: ...11 90 Symbol DS6707 Digital Imager Scanner Product Reference Guide Send Graphic User Interface GUI Characters continued Send GUI R Send GUI S Send GUI T Send GUI U Send GUI V Send GUI W Send GUI X ...

Страница 351: ...11 91 Turn On Off Rule Sets Use these bar codes to turn rule sets on and off Send Graphic User Interface GUI Characters continued Send GUI Y Send GUI Z Turn On Rule Set 1 Turn On Rule Set 2 Turn On Rule Set 3 Turn On Rule Set 4 ...

Страница 352: ...DS6707 Digital Imager Scanner Product Reference Guide Turn On Off Rule Sets continued Use these bar codes to turn rule sets on and off Turn Off Rule Set 1 Turn Off Rule Set 2 Turn Off Rule Set 3 Turn Off Rule Set 4 ...

Страница 353: ...Advanced Data Formatting 11 93 Alphanumeric Keyboard Space Single Close Quote Dash ...

Страница 354: ...11 94 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard continued Comma ...

Страница 355: ...Advanced Data Formatting 11 95 Alphanumeric Keyboard continued ...

Страница 356: ...11 96 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard continued _ Underscore Single Open Quote ...

Страница 357: ...Advanced Data Formatting 11 97 Alphanumeric Keyboard continued NOTE Do not confuse the numeric bar codes below with those on the numeric keypad 0 1 2 3 4 5 ...

Страница 358: ...11 98 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard continued 6 7 8 9 A B C ...

Страница 359: ...Advanced Data Formatting 11 99 Alphanumeric Keyboard continued D E F G H I J ...

Страница 360: ...11 100 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard continued K L M N O P Q ...

Страница 361: ...Advanced Data Formatting 11 101 Alphanumeric Keyboard continued R S T U V W X ...

Страница 362: ...11 102 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard continued Y Z Cancel End of Message a b c ...

Страница 363: ...Advanced Data Formatting 11 103 Alphanumeric Keyboard continued d e f g h i j ...

Страница 364: ...11 104 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard continued k l m n o p q ...

Страница 365: ...Advanced Data Formatting 11 105 Alphanumeric Keyboard continued r s t u v w x ...

Страница 366: ...11 106 Symbol DS6707 Digital Imager Scanner Product Reference Guide Alphanumeric Keyboard continued y z ...

Страница 367: ...me Delay to Low Power Mode 92h 1 Minute 4 7 Trigger Mode 8Ah Auto Aim 4 9 Picklist Mode F0h 92h Disabled Always 4 10 Presentation Mode Time Delay F1h E9h Disable 3 Sec for Scanner with Base 4 11 Mobile Phone Display Mode F1h CCh Disable 4 13 Mobile Phone Decode Aggressiveness F1h D6h F1h D6h 4 14 Decode Session Timeout 88h 9 9 Sec 4 15 Timeout Between Decodes Same Symbol 89h 0 6 Sec 4 15 Beep Afte...

Страница 368: ...nhancement F1h 64h Disable 6 5 Presentation Mode Field of View F1h 61h Default Reduced 6 5 Image Capture Autoexposure F0h 68h Enable 6 6 Image Capture Illumination F0h 69h Enable 6 6 Illumination Bank Control F1h 3Bh Full 6 7 Fixed Exposure F4h F1h 37h 100 6 8 Fixed Gain F1h 38h 50 6 8 Gain Exposure Priority for Snapshot Mode F1h 32h Autodetect 6 9 Snapshot Mode Timeout F0h 43h 0 30 seconds 6 10 S...

Страница 369: ...idth F4h F0h 6Eh 400 6 23 Signature Capture Height F4h F0h 6Fh 100 6 23 Signature Capture JPEG Quality F0h A5h 65 6 23 Video View Finder F0h 44h Disable 6 24 Target Video Frame Size F0h 48h 2200 bytes 6 24 Video View Finder Image Size F0h 49h 1700 bytes 6 25 SSI Host Preferences Baud Rate 9Ch 9600 5 5 Parity 9Eh None 5 7 Check Parity 97h Enable 5 8 Software Handshaking 9Fh ACK NAK 5 8 Host RTS Lin...

Страница 370: ...ck Override Disable 7 10 USB Ignore Unknown Characters Enable 7 11 Emulate Keypad Disable 7 11 Emulate Keypad with Leading Zero Disable 7 12 USB Keyboard FN1 Substitution Disable 7 12 Function Key Mapping Disable 7 13 Simulated Caps Lock Disable 7 13 Convert Case No Case Conversion 7 14 USB Static CDC Enable 7 14 RS 232 Host Parameters RS 232 Host Types Standard1 8 7 Baud Rate 9600 8 8 Parity Type...

Страница 371: ...le 10 9 EAN 13 JAN 13 03h Enable 10 10 Bookland EAN 53h Disable 10 10 Decode UPC EAN JAN Supplementals 2 and 5 digits 10h Ignore 10 11 User Programmable Supplementals Supplemental 1 Supplemental 2 F1h 43h F1h 44h 10 14 UPC EAN JAN Supplemental Redundancy 50h 10 10 15 UPC EAN JAN Supplemental AIM ID Format F1h A0h Combined 10 16 Transmit UPC A Check Digit 28h Enable 10 17 Transmit UPC E Check Digit...

Страница 372: ...able 10 30 ISBT 128 54h Enable 10 30 ISBT Concatenation F1h 41h Disable 10 31 Check ISBT Table F1h 42h Enable 10 32 ISBT Concatenation Redundancy DFh 10 10 32 Code 39 Code 39 00h Enable 10 33 Trioptic Code 39 0Dh Disable 10 33 Convert Code 39 to Code 32 Italian Pharmacy Code 56h Disable 10 34 Code 32 Prefix E7h Disable 10 34 Set Length s for Code 39 12h 13h 2 to 55 10 35 Code 39 Check Digit Verifi...

Страница 373: ...able 10 49 Convert I 2 of 5 to EAN 13 52h Disable 10 50 Discrete 2 of 5 DTF Discrete 2 of 5 05h Disable 10 51 Set Length s for D 2 of 5 14h 15h 12 10 51 Codabar NW 7 Codabar 07h Disable 10 53 Set Lengths for Codabar 18h 19h 5 to 55 10 53 CLSI Editing 36h Disable 10 55 NOTIS Editing 37h Disable 10 55 MSI MSI 0Bh Disable 10 56 Set Length s for MSI 1Eh 1Fh 4 to 55 10 56 MSI Check Digits 32h One 10 57...

Страница 374: ...git 5Fh Enable 10 66 UK Postal 5Bh Enable 10 66 Transmit UK Postal Check Digit 60h Enable 10 67 Japan Postal F0h 22h Enable 10 67 Australian Postal F0h 23h Enable 10 68 Australia Post Format F1h CEh Autodiscriminate 10 69 Netherlands KIX Code F0h 46h Enable 10 70 USPS 4CB One Code Intelligent Mail F1h 50h Disable 10 70 UPU FICS Postal F1h 63h Disable 10 71 GS1 DataBar GS1 DataBar 14 F0h 52h Enable...

Страница 375: ...h 24h Enable 10 80 Data Matrix Inverse F1h 4Ch SR DC Regular DP HD Autodetect 10 81 Maxicode F0h 26h Enable 10 82 QR Code F0h 25h Enable 10 82 QR Inverse F1h 4Bh SR DC Regular DP HD Autodetect 10 83 MicroQR F1h 3Dh Enable 10 84 Aztec F1h 3Eh Enable 10 84 Aztec Inverse F1h 4Dh SR DC Regular DP HD Autodetect 10 85 Symbology Specific Security Levels Redundancy Level 4Eh 1 10 86 Security Level 4Dh 1 1...

Страница 376: ...de Macro PDF Flush Macro PDF Buffer 10 90 Abort Macro PDF Entry 10 90 Table A 1 Standard Default Parameters Table Continued Parameter Parameter Number Default Page Number 1 User selection is required to configure this interface and this is the most common selection ...

Страница 377: ... A UPC E UPC E1 EAN 8 EAN 13 B Code 39 Code 32 C Codabar D Code 128 ISBT 128 ISBT 128 Concatenated E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5 or Discrete 2 of 5 IATA H Code 11 J MSI K GS1 128 L Bookland EAN M Trioptic Code 39 N Coupon Code R GS1 DataBar Family S Matrix 2 of 5 T UCC Composite TLC 39 U Chinese 2 of 5 ...

Страница 378: ...7 z Aztec Aztec Rune P00 Data Matrix P01 QR Code MicroQR P02 Maxicode P03 US Postnet P04 US Planet P05 Japan Postal P06 UK Postal P08 Netherlands KIX Code P09 Australian Postal P0A USPS 4CB One Code Intelligent Mail P0B UPU FICS Postal P0X Signature Capture Table B 1 Symbol Code Characters Continued Code Character Code Type ...

Страница 379: ...28 Concatenated GS1 128 Coupon Code 128 portion d Data Matrix E UPC EAN Coupon UPC portion e GS1 DataBar Family F Codabar G Code 93 H Code 11 I Interleaved 2 of 5 L PDF417 Macro PDF417 Micro PDF417 L2 TLC 39 M MSI Q QR Code MicroQR S Discrete 2 of 5 IATA 2 of 5 U Maxicode z Aztec Aztec Rune X Bookland EAN ISSN EAN Trioptic Code 39 Chinese 2 of 5 Matrix 2 of 5 Korean 3 of 5 US Postnet US Planet UK ...

Страница 380: ...is transmitted as X0412356 Code 128 0 Standard data packet no Function code 1 in first symbol position 1 Function code 1 in first symbol character position 2 Function code 1 in second symbol character position Example A Code EAN 128 bar code with Function 1 character FNC1 in the first position AIMID is transmitted as C1AIMID I 2 of 5 0 No check digit processing 1 Reader has validated check digit 3...

Страница 381: ...ck digits 3 Check characters validated but not transmitted GS1 DataBar Family No option specified at this time Always transmit 0 DataBar 14 and DataBar Limited transmit with an Application Identifier 01 Note In GS1 128 emulation mode GS1 DataBar is transmitted using Code 128 rules i e C1 Example A DataBar 14 bar code 0110012345678902 is transmitted as e00110012345678902 EAN UCC Composites GS1 Data...

Страница 382: ...mitted 3 The bar code contains a GS1 128 symbol and the first codeword is 903 907 912 914 915 4 The bar code contains a GS1 128 symbol and the first codeword is in the range 908 909 5 The bar code contains a GS1 128 symbol and the first codeword is in the range 910 911 Example A PDF417 bar code ABCD with no transmission protocol enabled is transmitted as L2ABCD Data Matrix 0 ECC 000 140 not suppor...

Страница 383: ...t implemented FNC1 implied in first position 4 Model 2 symbol ECI protocol implemented FNC1 implied in first position 5 Model 2 symbol ECI protocol not implemented FNC1 implied in second position 6 Model 2 symbol ECI protocol implemented FNC1 implied in second position Aztec 0 Aztec symbol C Aztec Rune symbol Table B 3 Modifier Characters Continued Code Type Option Value Option ...

Страница 384: ...B 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 385: ...Appendix C Sample Bar Codes Code 39 UPC EAN UPC A 100 123ABC 0 12345 67890 5 ...

Страница 386: ...C 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide EAN 13 100 Code 128 Interleaved 2 of 5 3 456789 012340 1 2 3 4 5 6 7 8 9 0 12345678901231 ...

Страница 387: ...Sample Bar Codes C 3 GS1 DataBar 14 7612341562341 PDF417 Data Matrix NOTE GS1 DataBar 14 must be enabled to read the bar code below see GS1 DataBar 14 on page 10 72 ...

Страница 388: ...C 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide Maxicode QR Code US Postnet ...

Страница 389: ...Sample Bar Codes C 5 UK Postal ...

Страница 390: ...C 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide ...

Страница 391: ...Appendix D Numeric Bar Codes Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1 2 3 4 ...

Страница 392: ...D 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide Numeric Bar Codes continued Cancel To correct an error or change a selection scan the bar code below 5 6 7 8 9 Cancel ...

Страница 393: ...1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M CTRL M ENTER1 1014 N CTRL N 1015 O CTRL O The keystroke in bold transmits only if Function Key Mapping is enabled Otherwise the unbold keystroke transmits ...

Страница 394: ... X 1025 Y CTRL Y 1026 Z CTRL Z 1027 A CTRL 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K Table E 1 ASCII Value Table Continued ASCII Value Full ASCII Code 39 Encode Char Keystroke The keystroke in bold transmits only if Function Key Mapping is enabled Otherwise the unbold keystroke transmits ...

Страница 395: ...8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G Table E 1 ASCII Value Table Continued ASCII Value Full ASCII Code 39 Encode Char Keystroke The keystroke in bold transmits only if Function Key Mapping is enabled Otherwise the unbold keystroke transmits ...

Страница 396: ... 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c Table E 1 ASCII Value Table Continued ASCII Value Full ASCII Code 39 Encode Char Keystroke The keystroke in bold transmits only if Function Key Mapping is enabled Otherwise the unbold keystroke transmits ...

Страница 397: ... 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q I 1125 R 1126 S Table E 1 ASCII Value Table Continued ASCII Value Full ASCII Code 39 Encode Char Keystroke The keystroke in bold transmits only if Function Key Mapping is enabled Otherwise the unbold keystroke transmits ...

Страница 398: ... Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z ...

Страница 399: ... 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O Note GUI Shift Keys The Apple iMac keyboard has an apple key on either side of the space bar Windows based systems have a GUI key to the left of the left ALT key and to the right of the right ALT key ...

Страница 400: ... GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Table E 3 USB GUI Key Character Set Continued GUI Key Keystroke Note GUI Shift Keys The Apple iMac keyboard has an apple key on either side of the space bar Windows based systems have a GUI key to the left of the left ALT key and to the right of the right ALT key ...

Страница 401: ... Table E 4 PF Key Standard Default Table PF Keys Keystroke 4001 PF 1 4002 PF 2 4003 PF 3 4004 PF 4 4005 PF 5 4006 PF 6 4007 PF 7 4008 PF 8 4009 PF 9 4010 PF 10 4011 PF 11 4012 PF 12 4013 PF 13 4014 PF 14 4015 PF 15 4016 PF 16 ...

Страница 402: ... F key Standard Default Table F Keys Keystroke 5001 F 1 5002 F 2 5003 F 3 5004 F 4 5005 F 5 5006 F 6 5007 F 7 5008 F 8 5009 F 9 5010 F 10 5011 F 11 5012 F 12 5013 F 13 5014 F 14 5015 F 15 5016 F 16 5017 F 17 5018 F 18 5019 F 19 5020 F 20 5021 F 21 5022 F 22 5023 F 23 5024 F 24 ...

Страница 403: ...r Sets E 11 Table E 6 Numeric Key Standard Default Table Numeric Keypad Keystroke 6042 6043 6044 Undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock ...

Страница 404: ... Keypad Standard Default Table Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow ...

Страница 405: ...mination is made the information content is decoded B Bar The dark element in a printed bar code symbol Bar Code A pattern of variable width bars and spaces which represents numeric or alphanumeric data in machine readable form The general format of a bar code symbol consists of a leading margin start character data or message character check character if any stop character and trailing margin Wit...

Страница 406: ...n if all laser output were directed into the eye s pupil There are no special operating procedures for this class CDRH Class 2 No additional software mechanisms are needed to conform to this limit Laser operation in this class poses no danger for unintentional direct human exposure Character A pattern of bars and spaces which either directly represents data or indicates a control function such as ...

Страница 407: ...umbers encoded within a bar code symbol Decryption Decryption is the decoding and unscrambling of received encrypted data Also see Encryption and Key Depth of Field The range between minimum and maximum distances at which a scanner can read a symbol with a certain minimum element width Discrete 2 of 5 A binary bar code symbology representing each character by a group of five bars two of which are ...

Страница 408: ... software restriction of 120 seconds of laser operation within any 1000 second window and an automatic laser shutdown if the scanner s oscillating mirror fails Input Output Ports I O ports are primarily dedicated to passing information into or out of the device s memory such as serial and USB ports Intercharacter Gap The space between two adjacent bar code characters in a discrete code Interleaved...

Страница 409: ... the data Also see Encryption and Decrypting L LASER Light Amplification by Stimulated Emission of Radiation The laser is an intense light source Light from a laser is all the same frequency unlike the output of an incandescent bulb Laser light is typically coherent and has a high energy density Laser Diode A gallium arsenide semiconductor type of laser connected to a power source to generate a la...

Страница 410: ...ce ODI Novell s driver specification for an interface between network hardware and higher level protocols It supports multiple protocols on a single NIC Network Interface Controller It is capable of understanding and translating any network information or request sent by any other ODI compatible protocol into something a NetWare client can understand and process Open System Authentication Open Sys...

Страница 411: ...ng no dark marks which precedes the start character of a bar code symbol and follows the stop character QWERTY A standard keyboard commonly used on North American and some European PC keyboards QWERTY refers to the arrangement of keys on the left side of the third row of keys R RAM Random Access Memory Data in RAM can be accessed in random order and quickly written and read Reflectance Amount of l...

Страница 412: ...med by the background between bars Specular Reflection The mirror like direct reflection of light from a surface which can cause difficulty decoding a bar code Start Stop Character A pattern of bars and spaces that provides the scanner with start and stop reading instructions and scanning direction The start and stop characters are normally to the left and right margins of a horizontal code STEP S...

Страница 413: ...emulates a character based mainframe session on a remote non mainframe terminal including all display features commands and function keys The VC5000 Series supports Terminal Emulations in 3270 5250 and VT220 Terminate and Stay Resident TSR A program under DOS that ends its foreground execution to remain resident in memory to service hardware software interrupts providing background operation It re...

Страница 414: ...nner Product Reference Guide V Visible Laser Diode VLD A solid state device which produces visible laser light W Warm Boot A warm boot restarts the mobile computer by closing all running programs All data that is not saved to flash memory is lost ...

Страница 415: ...replace 11 32 move cursor to start of data 11 31 move cursor to string and replace 11 31 numeric keypad 11 25 11 26 pad spaces 11 39 pad zeros 11 43 rules 11 1 rules hierarchy 11 4 send alt characters 11 67 send control characters 11 48 send function key 11 78 send keyboard characters 11 53 send keypad characters 11 73 send preset value 11 32 send value 11 37 skip ahead n characters 11 32 skip ahe...

Страница 416: ...6 beeper tone 4 5 beeper volume 4 6 bits per pixel 6 19 6 22 bookland EAN 10 10 bookland ISBN 10 24 buffering 10 38 cancel D 2 Chinese 2 of 5 10 59 codabar 10 53 codabar CLSI editing 10 55 codabar lengths 10 53 10 54 codabar NOTIS editing 10 55 code 11 10 43 code 11 lengths 10 43 10 44 code 128 10 28 10 30 code 128 emulation 10 79 code 128 lengths 10 28 code 39 10 33 transmit buffer 10 39 code 39 ...

Страница 417: ... 4 10 postal 10 65 prefix suffix values 4 21 presentation mode field of view 6 5 QR code 10 82 QR inverse 10 83 redundancy level 10 86 report version 10 89 RS 232 baud rate 8 8 beep on bel 8 18 check receive errors 8 13 data bits 8 12 default table 8 4 hardware handshaking 8 13 8 14 8 15 host serial response time out 8 17 host types 8 7 intercharacter delay 8 19 parity 8 11 RTS line state 8 18 sof...

Страница 418: ...43 lengths 10 43 10 44 code 128 bar codes code 128 10 28 10 30 GS1 128 10 30 ISBT concatenation 10 31 10 32 ISBT concatenation redundancy 10 32 lengths 10 28 code 128 emulation bar codes 10 79 code 39 bar codes buffering 10 38 check digit verification 10 36 code 39 10 33 full ASCII 10 37 lengths 10 35 transmit check digit 10 37 code 93 bar codes code 93 10 41 lengths 10 41 10 42 code identifiers A...

Страница 419: ...15 image resolution 6 13 imaging preferences parameters 6 2 intellistand 2 7 2 9 interleaved 2 of 5 bar codes check digit verification 10 49 convert to EAN 13 10 50 transmit check digit 10 49 J JPEG image options 6 14 size quality 6 15 JPEG target file size 6 15 K Korean 3 of 5 bar codes 10 63 L LED definitions 2 4 low light enhancement 6 5 M macro PDF 10 90 macro PDF bar codes abort macro PDF ent...

Страница 420: ...installing the cable 1 3 unpacking 1 2 signal descriptions 3 8 signature capture 6 20 bits per pixel 6 22 file format selector 6 21 height 6 23 JPEG quality 6 23 width 6 23 snapshot mode timeout 6 10 specifications 3 4 SSI connection 5 2 SSI default parameters 5 4 standard default parameters A 1 support xix symbology default parameters 10 2 T technical specifications 3 4 troubleshooting 3 2 U unpa...

Страница 421: ..._______________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ What topics do you feel need to be better discussed Please be specific ____________________________________________________...

Страница 422: ......

Страница 423: ......

Страница 424: ...A 1 800 927 9626 http www motorola com MOTOROLA MOTO MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings LLC and are used under license All other trademarks are the property of their respective owners 2010 Motorola Inc All rights reserved ...

Отзывы: