10 Troubleshooting
98
This document is uncontrolled pending incorporation in PDM
Problem
Possible Solution
After resolving your problem, be sure to re-enable wireless security.
On the Wireless Basic Page:
• Check whether you turned on Disable SSID Broadcast. If it is on, be sure
the network name (SSID) on each affected wireless client is identical to the
SSID on the SBG901.
• On the Wireless Access Control Page, be sure the MAC address for each
affected wireless client is correctly listed.
Slow wireless
transmission speed with
WPA enabled
On the Wireless Security Page, check whether the WPA Encryption type is
TKIP. If all of your wireless clients support AES, change the WPA
Encryption to AES.
Front-Panel LEDs and Error Conditions
The SBG901 front panel LEDs provide status information for the following error conditions:
Table 32 Front-Panel LEDs and Error Conditions
LED
Status
If, During Startup:
If, During Normal Operation:
POWER
OFF
The SBG901 is not properly plugged
into the power outlet
The SBG901 is unplugged
RECEIVE
FLASHING
The downstream receive channel
cannot be acquired
The downstream channel is lost
SEND
FLASHING
The upstream send channel cannot be
acquired
The upstream channel is lost
ONLINE
FLASHING
IP registration is unsuccessful
The IP registration is lost
Содержание SURFboard SBG901
Страница 1: ...Motorola SURFboard SBG901 Wireless Cable Modem Gateway User Guide ...
Страница 46: ...3 Basic Configuration 46 This document is uncontrolled pending incorporation in PDM ...
Страница 78: ...8 Parental Control Pages 78 This document is uncontrolled pending incorporation in PDM ...
Страница 96: ...9 Wireless Pages 96 This document is uncontrolled pending incorporation in PDM ...
Страница 100: ...11 Contact Us 100 This document is uncontrolled pending incorporation in PDM ...
Страница 104: ...A Specifications 104 This document is uncontrolled pending incorporation in PDM ...