Installation
2 - 7
Housing Design
Design the engine’s housing so that internal reflections from the aiming and illumination system are not directed
back toward the engine. The reflections from the window or housing can cause problems, and for particular window
tilt angles, these reflections can bounce off the top or bottom of the housing and reach the engine. Avoid any bright
objects around the engine that can be reflected by a tilted window into the engine field of view and appear in a
captured image.
Recommended Exit Window Information on page 2-11
provides minimum exit window tilt angles. These
dimensional requirements can vary. Consider using baffles or matte-finished dark internal housing colors.
Optical
The SE4710 uses a sophisticated optical system that provides imaging performance that matches or exceeds the
performance of much larger imagers. However, an improperly designed enclosure, or improper selection of window
material, can affect the performance of the SE4710.
Positioning the Exit Window
Position the window so that illumination system light reflected off the inside of the window is not reflected back into
the engine (see
Recommended Exit Window Information on page 2-11
). If the designed enclosure cannot
accommodate the recommended window angle, contact Motorola to discuss positioning requirements. An
improperly positioned window can significantly decrease performance.
Window Positioning Options
There are two options for window positioning:
•
Parallel window - This is the preferred method for imager engines. Adhere to the maximum window distance
specifications in
.
•
Tilted window - This is used for either laser or imager engines. Adhere to the minimum window tilt
specifications in
.
Avoiding Scratched Windows
Scratches on the window can greatly reduce the performance of the imaging system. Motorola recommends
recessing the window into the housing or applying a scratch resistance coating.
NOTE
Perform an opto-mechanical analysis for the housing design to ensure optimal scanning or imaging
performance.
NOTE
For bar code reading, use either a parallel or tilted window. For document capture applications, Motorola
strongly recommends the parallel window installation. For tilted windows, dust, contamination, and
scratches on the window can cause visible blemishes in the images.
Содержание SE4710
Страница 1: ...SE4710 INTEGRATION GUIDE ...
Страница 2: ......
Страница 3: ...SE4710 INTEGRATION GUIDE MN000130A01 Revision A March 2014 ...
Страница 6: ...iv SE4710 Integration Guide ...
Страница 10: ...viii SE4710 Integration Guide ...
Страница 14: ...xii SE4710 Integration Guide ...
Страница 18: ...1 4 SE4710 Integration Guide ...
Страница 28: ...2 10 SE4710 Integration Guide Optical Path Figure 2 5 SE4710 Optical Path ...
Страница 38: ...3 8 SE4710 Integration Guide Sample Current Scope Plots Figure 3 1 VCC_ILLUM Current Figure 3 2 VCC Current ...
Страница 39: ...Specifications 3 9 Figure 3 3 VDD_IO Host Current Figure 3 4 Total Current VCC_ILLUM VCC VDD_IO ...
Страница 42: ...3 12 SE4710 Integration Guide ...
Страница 46: ...4 4 SE4710 Integration Guide Figure 4 2 MIPI Host Flex p n PF000084A01 ...
Страница 47: ...Electrical Interface 4 5 Figure 4 3 Parallel Host Flex p n PF000062A01 ...
Страница 72: ...6 10 SE4710 Integration Guide ...
Страница 74: ...A 2 SE4710 Integration Guide ...
Страница 78: ...Index 4 SE4750 Integration Guide ...
Страница 80: ......
Страница 81: ......