11
Lightning
Protection
161
11.3.1 Pre-Power Testing
Before plugging the RJ45 from the lower LPU (or if not fitted the ODU) into the PIDU, check
the following resistances at the RJ45:
1. Check the cable resistance between pins 1&2, 3&6, 4&5 and 7&8 at the RJ45. Check
against column 2 in Table 23. Resistances for each pair should be within 1 ohm of each
other.
2. Check the cable resistance between pins 1&3 and 4&7 at the RJ45. Check against
columns 3 and 4 respectively in Table 23.
3. Ensure that there is greater than 100K ohms between pins 1&8 for all cable lengths.
4. Ensure that there is greater than 100K ohms between pin 1 and ODU ground for all cable
lengths.
5. Ensure that there is greater than 100K ohms between pin 8 and ODU ground for all cable
lengths.
CAT-5
Length
(Meters)
Resistance between
pins 1&2, 3&6 , 4&5 and
pins 7&8 (ohms)
Resistance between
pins 1&3 (ohms)
Resistance
between pins 4&7
(ohms)
0 0.8
1.0
1.6
10 2.5
2.7
3.3
20 4.2
4.4
5.0
30 5.9
6.1
6.7
40 7.6
7.8
8.4
50 9.3
9.5
10.1
60 11.0
11.2
11.8
70 12.7
12.9
13.5
80 14.4
14.6
15.2
90 16.1
16.3
16.9
100 17.8
18.0
18.6
Table 23 - Resistance Table Referenced To The RJ45 at the PIDU+
Содержание PTP 54500
Страница 1: ...PTP 500 Series User Guide MOTOROLA POINT TO POINT WIRELESS SOLUTIONS ...
Страница 2: ......
Страница 132: ...8 Web Page Reference 130 Figure 65 Spectrum Management Slave Screen With Operational Restrictions ...
Страница 190: ...14 Data Rate Calculations 188 Figure 111 QPSK 0 50 Single Payload Figure 112 QPSK 0 75 Single Payload ...
Страница 191: ...14 Data Rate Calculations 189 Figure 113 16 QAM 0 50 Single Payload Figure 114 16 QAM 0 75 Single Payload ...
Страница 192: ...14 Data Rate Calculations 190 Figure 115 64 QAM 0 67 Single Payload Figure 116 64 QAM 0 83 Single Payload ...
Страница 193: ...14 Data Rate Calculations 191 Figure 117 QPSK 0 50 Dual Payload Figure 118 QPSK 0 75 Dual Payload ...
Страница 194: ...14 Data Rate Calculations 192 Figure 119 16 QAM 0 50 Dual Payload Figure 120 16 QAM 0 75 Dual Payload ...
Страница 195: ...14 Data Rate Calculations 193 Figure 121 64 QAM 0 67 Dual Payload Figure 122 64 QAM 0 83 Dual Payload ...
Страница 205: ...16 Legal and Regulatory Notices 203 16 4 Exposure See Section 2 Avoiding Hazards ...