B - 6 D i a g n o s t i c s
DCT 2000 Installation Manual
Error Code
OSD
Cause
Remedy
E 09
BATTERY
Dead battery or memory has not been
initialized; occurs if battery fails to
keep the RAM alive during
power-down; causes DCT2000 to be
disconnected
Return DCT2000 for repair;
requires factory
initialization message
E 10
SERIALNO
Invalid serial number
Not used at this time
E 11
INVALID UNIT
ADDRESS
Invalid unit address
Return DCT2000 for repair;
requires a unit creation
message
E 12
POST ERROR
POST failed
Not used at this time
E 13
BOOT
Sys_boot initialization failure
Power cycle box; if
repetitive, return for repair
E 14
STARTUP
DCT2000 system startup failure
Power cycle box; if
repetitive, return for repair
E 15
TSI INVALID
TSI structure is corrupted
Power cycle box; if
repetitive, return for repair
E 16
FLASH BAD
NUMBER
Bad flash number specified for Initiate
Flash Platform
Error logged, ignore
E 17
BAD PLATVAL
Bad platform validation step number
Error logged, ignore
*E 00 and E 01 cannot be displayed while the DCT2000 is off. The other errors will display on
the LED display when the DCT2000 is off.
There are five different tuners that could appear on the OSD display:
V1000D2
V1000D3C
V860
V860D
V860DL
Содержание Mts-2000