Installation
56
as a hub/switch (and auto-sensing MDI/MDIX cross over is employed), connection can be made
directly to the computer using a standard CAT 5 patch cable.
Before physical installation takes place the units to be installed should be set up as described in
the
"Install Pages". It is recommended that this procedure be carried out on the
bench before physical installation commences. Providing it is safe to do so, the installer should
take the process to the point where a radio link is established before proceeding to the installation
site.
NOTE:
It is possible that some units may not be accessed using the above default URL. This is
because these units may have been previously configured with IP addresses 10.10.10.11 (Master)
and 10.10.10.10 (Slave). Therefore, users must use the URL http://10.10.10.10/ and/or URL
http://10.10.10.11/ to configure the units. Please ensure that a computer with web browsing
capabilities is configured with an IP address of 10.10.10.n, where n is any value between 2 and 254
but excluding 10 and 11, to configure these units.
7.7.11
Aligning the PTP 500 Series Bridge ODUs
The following is a description of the steps taken to establish a radio link between the two units
forming the bridge and align the units for the best signal strength.
The PTP 500 Series Bridge uses audible tones during installation to assist the installer with
alignment. The installer should adjust the alignment of the ODU in both azimuth and elevation
until highest pitch tone is achieved
. The tones and their meanings are as follows:
State Name
Tone Description
State Description
Pitch Indication
(Higher pitch =
higher power)
Free Channel Search
Regular beep
Executing band scan
N/A
Scanning
Slow broken tone
Not demodulating the
wanted signal
Rx Power
Synchronized
Fast broken tone
Demodulating the
wanted signal
Rx Power
Registered
Solid tone
Both Master and Slave
units exchanging Radio
layer MAC management
messages
Rx Power
Table 11
Audio indications from the ODU
The term ‘wanted signal’ refers to that of the peer unit being installed.
In each of the states detailed above, the unit should be aligned to give the highest pitch tone. It
should be noted that if, when in the Synchronized or Registered state, the tone varies wildly, you
The pitch of the alignment tone is proportional to the received power of the wireless signals. The best results are
usually achieved by making small incremental movement in angular alignment.
Содержание MOTOWI 4
Страница 1: ...PTP 500 Series User Guide phn 1115 000v001 ...
Страница 74: ...Web Page Reference 74 Figure 37 Save Configuration File Screen ...
Страница 100: ...Web Page Reference 100 Figure 59 Spectrum Management as seen from the Master ...
Страница 108: ...Web Page Reference 108 Figure 66 Spectrum Management Master Screen With Operational Restrictions ...
Страница 112: ...Web Page Reference 112 Figure 68 Remote Management ...
Страница 165: ...Data Rate Calculations 165 Figure 112 QPSK 0 50 Single Payload Figure 113 QPSK 0 75 Single Payload ...
Страница 166: ...Data Rate Calculations 166 Figure 114 16 QAM 0 50 Single Payload Figure 115 16 QAM 0 75 Single Payload ...
Страница 167: ...Data Rate Calculations 167 Figure 116 64 QAM 0 67 Single Payload Figure 117 64 QAM 0 83 Single Payload ...
Страница 168: ...Data Rate Calculations 168 Figure 118 256 QAM 0 75 Single Payload Figure 119 QPSK 0 50 Dual Payload ...
Страница 169: ...Data Rate Calculations 169 Figure 120 QPSK 0 75 Dual Payload Figure 121 16 QAM 0 50 Dual Payload ...
Страница 170: ...Data Rate Calculations 170 Figure 122 16 QAM 0 75 Dual Payload Figure 123 64 QAM 0 67 Dual Payload ...
Страница 171: ...Data Rate Calculations 171 Figure 124 64 QAM 0 83 Dual Payload Figure 125 256 QAM 0 75 Dual Payload ...
Страница 197: ...Glossary 197 UTP Unshielded Twisted Pair VLAN Virtual Local Area Network ...