Software Diagnostics Output
C-118
4.
DSR1 register parameters (See MC68302 Manual Page 4-119)
5.
SCCM1 register parameters (See MC68302 Manual Page 4-44)
6.
SCCE1 register parameters (See MC68302 Manual Page 4-44)
7.
SCCS1 register parameters (See MC68302 Manual Page 4-44)
8.
PACNT (PORT A Control register parameters) (See MC68302 Manual Page 3-33)
9.
PADDR (PORT A Direction register parameters) (See MC68302 Manual Page 3-35)
10.
PADAT (PORT A DATA register parameters)
## 2752 LEVEL = 2
********************************************
* MPT1327 SPECIFIC PARAMETERS (ASYNC MODE) *
********************************************
MAX_IDL
(Maximum IDLE Characters (Receive)) : %%1
IDLC
(Temporary Receive IDLE Counter)
: %%2
BRKCR
(Break Count Register (Transmit))
: %%3
---------------------------------------------------
PAREC
(Receive Parity Error Counter)
: %%4
FRMEC
(Receive Framing Error Counter)
: %%5
NOSEC
(Receive Noise Counter)
: %%6
BRKEC
(Receive Break Condition Counter)
: %%7
---------------------------------------------------
UADDR1
(UART ADDRESS Character 1)
: %%8
UADDR2
(UART ADDRESS Character 2)
: %%9
---------------------------------------------------
RCCR
(Receive Control Character Register): %%10
CHARACTER1 (CONTROL Character 1)
: %%11
CHARACTER2 (CONTROL Character 2)
: %%12
CHARACTER3 (CONTROL Character 3)
: %%13
CHARACTER4 (CONTROL Character 4)
: %%14
CHARACTER5 (CONTROL Character 5)
: %%15
CHARACTER6 (CONTROL Character 6)
: %%16
CHARACTER7 (CONTROL Character 7)
: %%17
CHARACTER8 (CONTROL Character 8)
: %%18
See MC68302 Manual Pages 4-53 to 4-55.
1.
Maximum IDLE Characters (Receive) (UART mode)
2.
Temporary Receive IDLE Counter (UART mode)
3.
Break Count Register (Transmit) (UART mode)
4.
Receive Parity Error Counter (UART mode)
5.
Receive Framing Error Counter (UART mode)
6.
Receive Noise Counter (UART mode)
7.
Receive Break Condition Counter) (UART mode)
8.
UART ADDRESS Character 1 (UART mode)