7.15
Stack Interface
Functionality of the MB68k-100 motherboard may be expanded through its Stack
Interface. This interface is designed to support additional circuitry by providing access to
the internal buses and control signaling.
7.15.1
Stack Interface Connectors
The MB68k-100 offers two 0.1" pitch headers, each with 2x32 pins, that may be used to
interface with a stack of mezzanine daughter boards. The connectors have reference
designators CON160 and CON161. The connectors are positioned on opposite sides of
the motherboard, parallel along their long dimensions. Two additional headers are
provided, CON162 and CON163. These are electrically pin-for-pin identical to the
former pair, respectively, and offer an additional opportunity for access. See Figure 12
on page 42 for a visual reference. See Table 19 and Table 20 for connector pin mapping.
The outermost pins on each side of each connector are connections to negative, ensuring
that the negative contact is made first in case of a hot insertion. This practice, however,
is not intended.
Table 19: Stack Connector CON160/CON162 Pin Map
Name
Description
Pin
Pin Name
Description
GND
Supply Negative
1
2
GND
Supply Negative
VCC
Supply Positive
3
4
VCC
Supply Positive
M68K_AS
!!
68000 Address
Strobe
5
6
M68K_UDS
!!!
68000 Upper Data
Strobe
M68K_LDS
!!!
68000 Lower
Data Strobe
7
8
M68K_R/W
!
68000 Read/Write
W/R
!
Inverted 68000
Read/Write
9
10
M68K_DTACK
!!!!!!
68000 Data Transfer
Acknowledge
DTACK_EXT
!!!!!!!!!
External
/DTACK input
11
12
AUTO_DTACK
!!!!!!
On-Board Automatic
/DTACK output
M68K_BG
!!
68000 Bus Grant
13
14
M68K_BGACK
!!!!!!
68000 Bus Grant
Acknowledge
M68K_BR
!!
68000 Bus
Request
15
16
CLKIN
Clock input
HXCLK_OUT
Symmetric
Discrete Clock
(Frequency/2)
17
18
CLKDIVOUT
Symmetric Clock
Frequency Divider
Output
CLK
System Clock
19
20
CLK
!!!
Inverted System
Clock
M68K_HALT
!!!!
68000 Halt
21
22
HALT_CMD
Input to Command
68000 Halt
M68K_RESET
!!!!!
68000 Reset
23
24
RESET_CMD
Input to Command
68000 Reset
RST_PULSE
Minimum One
Clock Cycle
Pulse on 68000
Reset Transition
from 0 to 1
25
26
RST_PULSE
!!!!!!!!!
Inverted
RST_PULSE