5. Installation and Operation
Installation and operation may only be conducted by authorized and qualified personnel.
5.1 Installing FPN5590
B
Install the FPN5590
B
in the prescribed position, on aflat, clean surface, and fasten with four M4
screws. The maximum allowed penetration of the mounting screws is 6 mm (7/32 in.)
The recommended screw tightening torque is 1.27 N
×
m (13.0 kgf
×
cm).
5.2 Connecting FPN5590
B
to Backup Battery and Radio
Warning
Risk of explosion if incompatible battery is used or battery is incorrectly
connected!
M5 screws are used on the terminal strip. The recommended screw tightening torque is 2.50 N
×
m
(25.5 kgf
×
cm).
Battery and Radio Connections
To Radio
12V Battery
Fuse
30A
Black
Red
Green
5.3 Operating Instructions
1. Set the ON/OFF switch to OFF.
2. Connect the AC power cable to the prescribed outlet.
3. Set the ON/OFF switch to ON. Check that the green ON indicator turns on.
6. Cleaning
Remove dirt with soft, clean brush.
Clean external surfaces only with soft cloth moistened with water. Avoid extensive contact with water.
5