Home Monitoring & Control System
Issues and Solutions
56
MHM
User
Guide
Door/Window sensor is displayed on the device list with a RED icon with a status of
no communication since …
The door/window sensor was discovered and functions properly, but is reporting a status of
no communication since last x minutes
. Take the following steps to correct this condition:
1
Check to see if the sensor LED turns on using the following procedure:
-Generate an opened or closed contact event.
-The LED should blink RED, blink GREEN, and then turn off.
-If the LED does not turn on, replace the batteries with a fresh pair. Be careful to
insert the batteries with the proper polarity.
2
Restart the MHM program and wait 15 to 20 minutes to see if the sensor icon turns
green.
3
Reposition the sensor to within five feet of the USB Gateway with a direct line of sight
from sensor antenna to USB Gateway antenna. Make sure that neither is close to any
metal object like a PC tower or electrical appliance.
4
Replace the batteries with a fresh pair since they may be discharged.
5
Go to the Discovery screen, delete the sensor, and rediscover it.
Temperature Sensor is displayed on the device list with a RED icon with a status of
no communication since …
The temperature sensor was discovered and functioned properly, but is reporting a status
of
no communication since last x minutes.
Take the following steps to correct this condition:
1
Check to see if the sensor LED turns on by using the following procedure:
-Remove or insert the external temperature probe.
-The LED should blink RED, blink GREEN, and then turn off.
-If the LED does turn on, replace the batteries with a fresh pair. Be careful to insert
the batteries with the proper polarity.
2
Restart the MHM program and wait 15 to 20 minutes to see if the sensor icon turns
green.
3
Reposition the sensor to within five feet of the USB Gateway with a direct line of sight
from sensor antenna to USB Gateway antenna. Make sure that neither is close to any
metal object like a PC tower or electrical appliance.
4
Replace the batteries with a fresh pair since they may be discharged.
5
Go to the Discovery screen, delete the sensor, and rediscover it.
Содержание EASY START KIT HMEZ1000 - CELL PHONE SET UP