BBBB ---- 8888
D i a g n o s t i c s
D C T 2 0 0 0 I n s t a l l a t i o n M a n u a l
d 03: In-Band Receiver Status
The DCT 2000 displays the in-band diagnostics for the last attempted channel tune. If a digital
carrier is not present, the diagnostics indicate the carrier lock is analog. When the carrier lock
is analog, all fields for digital, other than a carrier lock channel, are blank.
Figure B-6 illustrates the in-band receiver status as shown on the LED:
F i g u r e B - 6
I n - b a n d r e c e i v e r d i g i t a l s t a t u s
−
L E D
MUTE
MUTE
P
Data
activity
EMM
data
activity
IB diagnostic
indicator
PCR
lock
Modulation
mode
Carrier lock
Figure B-7 illustrates the IN-BAND DIAGNOSTIC (in-band receiver digital status) OSD:
F i g u r e B - 7
I N - B A N D D I A G N O S T I C ( i n - b a n d r e c e i v e r d i g i t a l s t a t u s )
−
O S D
IN-BAND DIAGNOSTIC
DATA
*
EMM DATA
*
CARRIER LOCK
YES
PCR LOCK
YES
SNR
47
ssss
AGC
23
ssss