68009328001-A
December, 2009
Radio Alignment Procedures:
Transmitter Alignment Options
5-9
5.4.4.1 VCO Attenuation 25 kHz
1.
Under the
Tx Align
menu, select
VCO Attenuation 25 kHz
(
Figure 5-6
).
2.
Begin with the lowest frequency. Select the thumb of the slider at the lowest frequency point and
then press the
PTT Toggle
button to key up the radio at the corresponding frequency point. The
spin control can also be toggled via its up/down arrow buttons. The softpot value can also be
typed into the edit control (press
ENTER
to confirm your selection/send a softpot value).
3. Inject 1 kHz
at an appropriate level until
2.3 V rms
is measured at the AC/DC METER (radio
input) if using test box
RLN4460
.
4.
Record the deviation obtained.
5.
Adjust the slider; adjust the spin control or key in softpot values (press
ENTER
to confirm) for the
frequency point until the deviation is within the range
specified in
Table 5-4
.
6.
Dekey the radio (Press the
PTT Toggle
button). Choose the next frequency, key up and repeat
steps 3 to 6 until all seven tuning points are done.
7.
Program the softpot value by pressing the
Program
button.
8.
Exit the VCO Attn. 25 kHz function.
5.4.4.2 VCO Attenuation 12.5 kHz
1.
Under the
Tx Align
menu, select
VCO Attenuation 12.5 kHz
.
2.
Press
PTT Toggle
to key up the radio at the last non-0 transmit frequency point (normally F7).
3.
Inject
1 kHz
at an appropriate level until
2.3 V rms
is measured at the AC/DC METER (radio
input) if using test box
RLN4460
.
4.
Record the deviation obtained.
5.
Adjust the slider, adjust the spin control or key in softpot values (press
ENTER
to confirm) for the
frequency point until the deviation is within the range
specified in
Table 5-4
.
6.
Press
PTT Toggle
to dekey the radio.
7.
Program the softpot value by pressing the
Program
button.
8.
Exit the VCO Attenuation 12.5 kHz function.
5.4.4.3 VCO Attenuation 20 kHz
1.
Under the
Tx Align
menu, select
VCO Attenuation 20 kHz
.
2.
Press
PTT Toggle
to key up the radio at the last non-0 transmit frequency point (normally F7).
3.
Inject
1 kHz
: at an appropriate level until
2.3 V rms
is measured at the AC/DC METER (radio
input) if using test box
RLN4460
.
4.
Record the deviation obtained.
5.
Adjust the slider; adjust the spin control or key in softpot values (press
ENTER
to confirm) for the
frequency point until the deviation is within the range
specified in
Table 5-4
.
6.
Press
PTT Toggle
to dekey the radio.
7.
Program the softpot value by pressing the
Program
button.
8.
Exit the VCO Attn. 20 kHz function.
Note: Tuning of Modulation Balance Attenutation and VCO Attenuation for 25 kHz channel
bandwidth must be done first.
Note: Tuning of Modulation Balance Attn. and VCO Attn. for 25 kHz channel bandwidth
must be done first.
Содержание Commercial Series
Страница 1: ......
Страница 2: ......
Страница 6: ...iv Notes ...
Страница 14: ...xi Table of Contents December 2009 68009328001 A Notes ...
Страница 24: ...October 2009 68009328001 A Notes 1 10 Model Charts and Test Specifications MIL Standards ...
Страница 36: ...October 2009 68009328001 A Notes 4 6 Performance Checks RF Test Mode ...
Страница 88: ...December 2009 68009328001 A Notes 9 4 Troubleshooting Tables Troubleshooting Table for Transmitter ...
Страница 92: ...October 2009 68009328001 A Notes A 4 Accessories ...
Страница 96: ...December 2009 68009328001 A Notes B 4 Warranty Service Support and Replacement Parts Technical Support ...
Страница 99: ......
Страница 100: ......