Parameter
Conditions
Min
Typ
Max
Units
Temperature
Operating range
-30
85
°C
Range
Tolerance
5
%
Resolution
1
°C
2.9.3
General Purpose A/D
The module provides 3 additional general purpose A/D (GPAD) signals for customer application use.
Each A/D signal can monitor a separate external voltage and report its measured level independently to
the application, through the AT command interface. The A/D Signals are available at the connector in the
following pins: 37, 43 and 47.
The GPAD signals can sense a DC voltage level of 0 – 2.3 V, which is converted internally to a 10-bit
digital value.
TABLE 22 – GPAD Specifications
Parameter
Conditions
Min
Typ
Max
Units
Input Voltage
0
2.9
V
Sampling
0.05
2.5
V
Range
Resolution
10
mV
Motorola General Business Use
Page 31 of 36
Applicant: Motorola, INC
FCC ID: IHDP56JE1