6. If it is not displayed, click

to display the Site View Editor and choose where the device appears in the

System Explorer.

l

In the

site directory, drag devices up and down the right pane to set where it is displayed.

l

If your site includes

folders, select a location for the device in the left pane. The right pane

updates to show what is stored in that directory.

l

If you are connecting multiple devices at the same time, the selected devices must be assigned to
the same location.

Tip:

If the site you want is not listed, you may need to connect the device to a different server. Make sure

the selected server is connected to the site you want.

7. Click

OK

.

8. If the device is password protected, the Device Authentication dialog box appears. Enter the device's

username and password, then click

OK

.

Setting the Recording Schedule

Once all the cameras have been connected, you can set when you want each camera to record video.

By default, all connected cameras are set to record when events are detected by the system. You can skip this
procedure if you prefer to keep the default settings.

Before you can assign a recording schedule, you must create a template. The template allows you to assign the
same schedule to multiple cameras.

Creating a Recording Template

The events that can be selected for the template depend on the licensed features in your system.

1. In the server Setup tab, click

. The Recording Schedule dialog box is displayed.

2. Click

Add Template

below the Templates: list.

3. Enter a name for the

New Template

.

4. Click the

Set Area

button, then click or drag the cursor across the

Recording Mode:

timeline to set the

types of events that the cameras will record throughout the day. Individual rectangles on the Recording
Mode: timeline are colored when they have been selected.

The

Recording Mode:

options include:

l

Continuous

— record video constantly.

l

Motion

— only record video when motion is detected.

l

POS Transactions

— only record video when a point of sale (POS) transaction is made.

l

License Plates

— only record video when a license plate is detected.

5. To disable recording in parts of the template, click the

Clear Area

button, then click or drag the cursor

across the timeline to remove the set recording areas.

Setting the Recording Schedule

10

Содержание avigilon HD-NVR4-STD-16TB

Страница 1: ...Installation Guide Avigilon HD Network Video Recorder HD NVR4 STD 16TB HD NVR4 STD 24TB HD NVR4 STD 32TB and HD NVR4 STD 48TB...

Страница 2: ...demark patent or other intellectual property rights of Avigilon Corporation or its licensors This document has been compiled and published using product descriptions and specifications available at th...

Страница 3: ...ware 6 Networking 6 Configuring the Avigilon Control Center Software 7 Starting Up and Shutting Down the Avigilon Control Center Client Software 7 Starting Up the Client Software 7 Shutting Down the C...

Страница 4: ...lacing a Hard Drive Blank 16 Replacing Front or Back Hard Drives 18 LED Indicators 19 Diagnostic Indicators 19 Power Status Indicators 19 Network Link Status Indicators 20 Hard Drive RAID Status Indic...

Страница 5: ...site Overview Front View 1 Bezel Protects against unauthorized physical access to the hard drives 2 Power button Controls the power supply to the recorder 3 Hard drives Provides access to hot swappab...

Страница 6: ...Accepts an OOBM RJ 45 connection 2 Serial connector Accepts connections to serial devices 3 Video connector Accepts a VGA monitor connection 4 USB connectors Accepts USB connections to external devic...

Страница 7: ...Connecting Cables Refer to the diagrams in the Overview section for the location of the different connectors Make the following connections as required 1 Connect a KVM switch or separate keyboard mou...

Страница 8: ...4 Set a password for the user name you entered on the previous screen When you are ready click Next 5 Once logged in the recorder will go through initial system setup 6 The Setup dialog will start co...

Страница 9: ...s to log in dialog box is displayed If you are connected only to the new recorder one site is listed in the left navigation panel The default name is HDVA 3 Double click the new recorder name to log i...

Страница 10: ...remove deactivate and reactivate licenses for the ACC 6 software For more information see the Avigilon Control Center Client User Guide Downgrading to the ACC 5 Software 1 Open Windows Settings Apps F...

Страница 11: ...trol Center Client l Double click or desktop shortcut icon When you are prompted log in to your site You can only access cameras and video after you log in Once the application has started it will aut...

Страница 12: ...twork authentication protocol Contact your network administrator for help 4 Click Log In You are logged into the selected sites If you want to be notified when new or disconnected sites come online se...

Страница 13: ...ick The Connect Disconnect Devices tab is displayed 2 In the Discovered Devices area select one or more devices then click Connect Tip You can also drag the device to a server on the Connected Devices...

Страница 14: ...this procedure if you prefer to keep the default settings Before you can assign a recording schedule you must create a template The template allows you to assign the same schedule to multiple cameras...

Страница 15: ...how long the full image rate video is kept so that you have the best quality video when you need it The amount of data aging that is available depends on the camera you have connected to your system...

Страница 16: ...of the options from the drop down list for each camera NOTE If the time estimated in the Total Record Time column is significantly shorter than what is set in the Max Record Time column the camera s a...

Страница 17: ...users do not have difficulty choosing new passwords d Select the required Group Privileges and Access Rights for the group Clear the check box of any feature or device that you do not want the group t...

Страница 18: ...of the password The strength is defined by the group the user is assigned to If the user is a member of more than one group the user must meet the strongest password requirement The password must meet...

Страница 19: ...vents dialog box to configure classified object motion detection or UMD Once configured you can receive events trigger alarms define rules and record video when classified object motion requires your...

Страница 20: ...he Windows software administrator username and password that was configured for the recorder 3 On the Server Administrator home page the health of the system components are displayed in the workspace...

Страница 21: ...place the blanks with hard drives as required 1 Remove the bezel a Unlock the bezel b Push the release button next to the lock c Pull the left end of the bezel then unhook the right end to remove the...

Страница 22: ...is not displayed in the Server Administrator try one of the following l Refresh the browser l Reboot the recorder Replacing Front or Back Hard Drives 1 Locate the failed hard drive at the front or ba...

Страница 23: ...t blocked Electrical l Blinks orange the recorder is experiencing an electrical error Errors include l voltage out of range l failed power supply l voltage regulator Check the power status indicator t...

Страница 24: ...corder s connection status LEDs above the Ethernet port display the recorder s connection status to the network The following table describes what the LEDs indicate Figure 3 1 Link LED 2 Connection ac...

Страница 25: ...ive is online Off The hard drive is disconnected from the recorder Two short green flashes every second The system is identifying a new hard drive or preparing a hard drive for removal Flashes green o...

Страница 26: ...VAC 50 60 Hz auto switching Power Consumption Average 270 W 921 3 BTU h Maxmium 750 W 2560 8 BTU h Power Supply 750 W single optional secondary power supply Environmental Operating Temperature 10 C to...

Страница 27: ...ue 6 EN 55032 2012 EN 55032 2015 CISPR 32 2012 CISPR 32 2015 Class A EN 61000 3 2 2014 IEC 61000 3 2 2014 Class D EN 61000 3 3 2013 IEC 61000 3 3 2013 Electromagnetic Immunity EN 55024 2010 A1 2015 CI...