01. SAFETY INSTRUCTIONS

to the release mechanism.

• Disconnect means, such as a switch or circuit breaker on the electrical 

panel, must be provided on the product’s fixed power supply leads in 

accordance with the installation rules.

• If the product to be installed requires power supply of 230Vac or 

110Vac, ensure that connection is to an electrical panel with ground 

connection.

•The product is only powered by low voltage satefy with central (only 

at 24V motors)

WARNINGS FOR USERS

• Keep this manual in a safe place to be consulted whenever necessary.

• If the product has contact with fluids without being prepared, it must 

immediately disconnect from the power supply to avoid short circuits, 

and consult a specialized technician.

• Ensure that technician has provided you the product manual and 

informed you how to handle the product in an emergency.

• If the system requires any repair or modification, unlock the 

automatism, turn off the power and do not use it until all safety 

conditions have been met.

• In the event of tripping of circuits breakers of fuse failure, locate 

the malfunction and solve it before resetting the circuit breaker or 

replacing the fuse. If the malfunction is not repairable by consult this 

manual, contact a technician.

• Keep the operation area of the motorized gate free while the gate in 

in motion, and do not create strength to the gate movement.

• Do not perform any operation on mechanical elements or hinges if 

the product is in motion.

RESPONSABILITY

• Supplier disclaims any liability if:

• Product failure or deformation result from improper installation 

use or maintenance!

• Safety norms are not followed in the installation, use and 

maintenance of the product.

• Instructions in this manual are not followed.

• Damaged is caused by unauthorized modifications

• In these cases, the warranty is voided.

SYMBOLS LEGEND:

• Important safety 

notices

• Useful information

• Programming 

information

• Potentiometer 

information

• Connectors 

information

• Buttons 

information

Содержание MPXRQ1MWS

Страница 1: ...V1 0 REV 02 2021 MPXRQ1MWS MPXRQ1MWS EN USER S AND INSTALLER S MANUAL...

Страница 2: ...ries eg Charger USB cable electronic material controls etc should not be disposed of as other household waste at the end of its useful life To avoid possible harm to the environment or human health re...

Страница 3: ...of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid 01 SAFETY INSTRUCTIONS the motorized door or ga...

Страница 4: ...r modification unlock the automatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction...

Страница 5: ...ered cards that is part of the control and management of access of a given location TECHNICAL CHARACTERISTICS BASIC CONTENT 01 01 MPXRQ1MWS 02 01 Embedding MPXRQ1MWS 03 02 Screw for fixing to the wall...

Страница 6: ...1 2 3 4 5 6 7 8 24mm 38mm 86mm 14mm 86mm 65mm EN Indicator LED 14 Pin Conectors RS485 Power Supply Input ID Setting MIFARE Card Area QR Code Area FRONT SIDE BACK 02 PRODUCT DIMENSIONS AND PRODUCT DIA...

Страница 7: ...he task that each device performs and which port access is installed The definition is made through the existing dip switch frame on the back of each reader according to the following table ID Dip swi...

Страница 8: ...3 OK2 OK1 ERR2 BZ2 EXTERNAL POWER CONNECTION 12Vdc Red 12Vdc Red RS485 RXD Blue RS485 TXD Yellow GND Black GND Black Recommended power supply 12Vdc 10 at least 500mA Comply with IEC EN 60950 1 standar...

Страница 9: ...IONS FOR FINAL CONSUMERS SPECIALIZED INSTALLERS DEVICE TEST To avoid self sensing interference from the touch sensor please do not touch the sensor when turning on the device power 1 When the power is...

Отзывы: