background image

3

EN

01. SAFETY INSTRUCTIONS

SYMBOLS LEGEND:

• Important safety 

notices

• Useful information

• Programming 

information

• Potentiometer 

information

• Connectors 

information

• Buttons 

information

September 2009.

• Attach the permanent label for the manual release as close as possible 

to the release mechanism.

• Disconnect means, such as a switch or circuit breaker on the electrical 

panel, must be provided on the product’s fixed power supply leads in 

accordance with the installation rules.

• If the product to be installed requires power supply of 230Vac or 

110Vac, ensure that connection is to an electrical panel with ground 

connection.

•The product is only powered by low voltage satefy with central (only 

at 24V motors)

WARNINGS FOR USERS

• Keep this manual in a safe place to be consulted whenever necessary.

• If the product has contact with fluids without being prepared, it must 

immediately disconnect from the power supply to avoid short circuits, 

and consult a specialized technician.

• Ensure that technician has provided you the product manual and 

informed you how to handle the product in an emergency.

• If the system requires any repair or modification, unlock the automatism, 

turn off the power and do not use it until all safety conditions have 

been met.

• In the event of tripping of circuits breakers of fuse failure, locate 

the malfunction and solve it before resetting the circuit breaker or 

replacing the fuse. If the malfunction is not repairable by consult this 

manual, contact a technician.

• Keep the operation area of the motorized gate free while the gate in in 

motion, and do not create strength to the gate movement.

• Do not perform any operation on mechanical elements or hinges if the 

product is in motion.

RESPONSABILITY

• Supplier disclaims any liability if:

• Product failure or deformation result from improper installation 

use or maintenance!

• Safety norms are not followed in the installation, use and 

maintenance of the product.

• Instructions in this manual are not followed.

• Damaged is caused by unauthorized modifications

• In these cases, the warranty is voided.

MOTORLINE ELECTROCELOS SA.

Travessa do Sobreiro, nº29

4755-474 Rio Côvo (Santa Eugénia)

Barcelos, Portugal

Содержание SLIDE1024

Страница 1: ...V4 3 REV 08 2022 SLIDE1024 EN USER S AND INSTALLER S MANUAL...

Страница 2: ...t and electronic accessories eg Charger USB cable electronic material controls etc should not be disposed of as other household waste at the end of its useful life To avoid possible harm to the enviro...

Страница 3: ...persons with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved 01 SAFETY INSTRUCTIONS Children shouldn t play with the product or openin...

Страница 4: ...re that technician has provided you the product manual and informed you how to handle the product in an emergency Ifthesystemrequiresanyrepairormodification unlocktheautomatism turn off the power and...

Страница 5: ...Fixing screws for the limit switch Motor fixing screws Floor fixing screws Fixing plate Remote controls Photocells Automated system for residential or industrial sliding gates with a maximum of 1000k...

Страница 6: ...ell 12 Guide 13 Gate 14 Fasteners 15 Battery box 16 Transformer 17 Control board 18 Motor cover 19 Unlocker 20 Motor housing 21 Motor mounting plate Use rigid and or flexible tubes suitable for the in...

Страница 7: ...ERIES BATTERIES BATTERIES If there is an obstacle that prevents access to the batteries you must change the orientation of the motor 03 INSTALLATION CHANGE MOTOR ORIENTATION Remove screws Rotate motor...

Страница 8: ...lied with the concrete still fresh see page 8 UNLOCK AUTOMATISM FOUNDATION CREATE FOUNDATION EXISTING FOUNDATION INSERT KEY TURN KEY After following these steps you can manually open close the gate Fo...

Страница 9: ...fasten the fixing plate to the floor using screws and anchor bolts not supplied in the kit NOTE It is important to leave one or more tubes to pass electrical cables through the plate 3 Using a level m...

Страница 10: ...he pinion 4 Close the gate slightly until the other end of the rack stands on top of the pinion and weld the other spacer to the gate 5 Close the gate slightly letting the rack stay on the pinion and...

Страница 11: ...with a level 2 Begin by fixing the rack on top of the pinion to the gate 3 Close the gate slightly until another end of the rack stands on top of the pinion and tightens 4 Apply another piece of rack...

Страница 12: ...can adjust the position of the magnetic field 1 Position the open limit switch magnet on the rack so that it can trigger the motor stop about 10 20 mm before the gate reaches the opening stopper 2 Fi...

Страница 13: ...components are faulty it is sometimes necessary to perform tests with a direct connec tion to an external power supply 24V ac battery The diagram below shows how this connection should be made NOTES I...