13
14
W
NC
COM
M
12
Z
90º
Ø10,5
90º
11
10
EN
EN
02. THE AUTOMATISM
02. THE AUTOMATISM
GEAR MOTOR WITH SAFETY DEVICE
INSTALLATION OF THE ELECTROBRAKE
03 • The downward run of the roller shutter
shall ben consistent with the downward
run of the safety brake. Place the gear
motor as shown in 13.
04 • For microswitch versions, connect the
micro switch’s cable (W) in series to the fee
ding cable (common) of the gearmotor (fi-
gure 14).
02 • After assembled the two elements of
the gearmotor (G), check that the pawl (Z)
is in the highest position perpendicular
to the rolling shutter axis (figure 12).
GEAR MOTOR WITH SAFETY DEVICE
Gear motor with safety device carried out to the stop the free fall of roller shutters and at
the same time, in microswitch versions, to interrupt the motoreductor’s feeding.
01 • Effect on the tube of the shutter a pas
sing perforation Ø10 perpendicular to the
axis (figure11).
Common
Brown
Black
Motor
Electrobrake
Capacitor
Switch
Power supply
230V
Shunt
Note • When installing the electrobrake on Rolling SP, rmove the shunt visible on image
10 ande make the connections of the electrobrake as visible on image 04.
Br
own
Blac
k
Common
ROLLING SP