INSTALLATION AND CONNECTIONS
To ensure the correct functioning of the MR65, please note the following indications:
• Prevent the installation site from having accumulation of snow or water on the ground;
• Adjust the sensor body so that it does not detect the door;
• The Radar part of the MR65 can be negatively influenced by metal from the detection
field;
• Install at a maximum height of 6.5 meters;
• Make sure no condensation forms on the sensor;
• Make sure there are no moving objects in the detection zone;
• Ensure minimal sunlight reflected from the floor;
• Use different frequency settings when there is more than one sensor nearby
Drill the fixing holes (3.5 mm) according to the fixing support markings.
Remove the sensor body from the fixing support.
DETAIL A
Secure the fixing support with the mounting screws provided.
Place the sensor body on the fixing support. Pass the cable through the fixing
support.
Make the connections according to the diagram below. (See detail A)
Red
Black
White
Green
Yellow
Blue
Gray
Brown
Power supply (no polarity)
Output 1 (Radar Output)
Output 2 (Radar Output)
Do not use
Sensor Wire