FUNC
EN
SELECTOR PROGRAMMING
SELECTOR PROGRAMMING
• FUNCTIONS
• PROGRAMMING
You can use the selector in two modes: Code and Free. In "code" it is necessary to put a
combination of four numbers (original code is 1234) to change the operating function.
Press and hold the FUNC 1 key (LOCK) for 5 sec. The selector
will beep and the light changes from red (Code mode) to green, indi-
cating that it is in free mode. Repeat the procedure to switch to code
mode.
Change the selector's function in "Code Mode":
Change the selector's function in "Free Mode":
Changing from "Code Mode" to "Free Mode":
01
• Press and hold the
FUNC button for 5 sec.
The selector will beep
and the LED turns
green.
In "free" mode, you can select the desired function by pressing it for
5sec, without having to put the password.
02
• Enter the code
(original - 1234).
03
• Press the FUNC
button to confirm.
04
• Choose one of the
functions described
above by pressing the
key corresponding to
the function.
In case of forgetting your password, follow the next steps:
Reset the Selector:
01
• Press and hold the
FUNC button for 10 sec.
The selector will beep
twice. First at 5 sec
and then at 10 sec.
01
• Unscrew the
screw cover (below the
switch) and remove
the rear panel.
03
• The selector beeps once confirming the reset's success. The password returns to 1234. Refit
the back cover and tighten the screw.
02
• With the selector
on, press the RESET
button on the board
for 40sec.
02
• Enter the code
(original - 1234).
03
• Press the FUNC
button to confirm.
05
• Press the FUNC
button to confirm.
07
• Press the FUNC
button to confirm
again. The new
password is now set.
04
• Enter a new code.
06
• Enter for a second
time the new code.
Always Closed
•
All radars and controllers are disabled. The lock is automatically triggered, which causes the door to
close.If you connect a fire alarm and put the door in this function, the door will not open if it receives
an alarm order.
Always Open
•
All radars and controllers are disabled. The door stays open.
Partial Opening (Automatic Operation)
•
The radars are activated. The door opens only partially (65% of total course) automatically. Whenever
activated this function, the door does a new path recognition.
Exit Only
•
The external radar is disabled and the lock is activated automatically. The controllers and inner radar
stay activated. Only opens for exiting people.
Total Opening (Automatic Operation)
•
All radars and controllers are activated. The door opens and closes automatically.
M CELE 01 Selector|
USER'S AND INSTALLER'S
MANUAL
Change Password: