Motorline professional M CELE 01 Скачать руководство пользователя страница 1

1

2

4

3

FUNC

1

2

4

8

9

10

7

5

6

3

9

8

7

6

5

4

3

2

1

EN

1

LED

6

Exit Only

2

Always Closed 

7

RESET Button

3

Partial Opening (Automatic Functioning)

8

Wall fixation

4

Always Open

9

Connector

5

Total Opening (Automatic Functioning)

10

Box screw

WIRE COLOR INPUT

DESCRIPTION

1

Grey

PED

Partial opening contact

2

Brown

PED

Partial opening contact

3

Orange

COM

Opening dry contact

4

Purple

PUL

Opening dry contact

5

Blue

SIG

Electric lock signal

6

Green

RIN

Internal sensor signal

7

White

REX

External sensor signal

*

Yellow

ACESS

Not used

8

Black

GND

(GND)

9

Red

15V

12V~36V DC Power Supply

TECHNICAL SPECIFICATIONS

CONNECTIONS DIAGRAM

• SELECTOR DESCRIPTION

The "M CELE 01"  selector has 5 operating modes: Total Opening, Total Closing, 

Partial Opening, Exit Only and Automatic Mode. These modes can be operated 

with or without a security password. This switch contains a LED (light effect) 

and a buzzer (sound effect) to assist the programming procedure. It is powered 

by 15VDC directly from the door's automatism. It contains memory in case of 

power failure.

M CELE 01 Selector| 

USER'S AND INSTALLER'S 

MANUAL

RECEIVER INSTALLATION

01. 

Mark the holder 

mounting points and 

drill the holes.

02. 

Point the holder and 

insert the dowels and 

screws.

03. 

Pass the wire and 

fit the connector on the 

selector.

04. 

Place the selector on 

the support. Leave the 

cable stretched.

Отзывы: