![Motorline professional M CELE 01 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/motorline-professional/m-cele-01/m-cele-01_users-and-installers-manual_1838707001.webp)
1
2
4
3
FUNC
1
2
4
8
9
10
7
5
6
3
9
8
7
6
5
4
3
2
1
EN
1
LED
6
Exit Only
2
Always Closed
7
RESET Button
3
Partial Opening (Automatic Functioning)
8
Wall fixation
4
Always Open
9
Connector
5
Total Opening (Automatic Functioning)
10
Box screw
Nº
WIRE COLOR INPUT
DESCRIPTION
1
Grey
PED
Partial opening contact
2
Brown
PED
Partial opening contact
3
Orange
COM
Opening dry contact
4
Purple
PUL
Opening dry contact
5
Blue
SIG
Electric lock signal
6
Green
RIN
Internal sensor signal
7
White
REX
External sensor signal
*
Yellow
ACESS
Not used
8
Black
GND
(GND)
9
Red
15V
12V~36V DC Power Supply
TECHNICAL SPECIFICATIONS
CONNECTIONS DIAGRAM
• SELECTOR DESCRIPTION
The "M CELE 01" selector has 5 operating modes: Total Opening, Total Closing,
Partial Opening, Exit Only and Automatic Mode. These modes can be operated
with or without a security password. This switch contains a LED (light effect)
and a buzzer (sound effect) to assist the programming procedure. It is powered
by 15VDC directly from the door's automatism. It contains memory in case of
power failure.
M CELE 01 Selector|
USER'S AND INSTALLER'S
MANUAL
RECEIVER INSTALLATION
01.
Mark the holder
mounting points and
drill the holes.
02.
Point the holder and
insert the dowels and
screws.
03.
Pass the wire and
fit the connector on the
selector.
04.
Place the selector on
the support. Leave the
cable stretched.