6A5

EN

POTENTIOMETERS

05. CONFIGURATION 

Power and sensitivity potentiometer adjustment:

Power potentiometer controls the power and speed of motor when opening and closing. 

Sensitivity potentiometer controls the sensitivity of control board in detecting obstacles. The more sen-

sitivity the control board, the faster will detect any obstacle along the way and reverse the direction of 

motor operation. 

01 •

 To adjust the potentiometers, just turn them with a small key. Turning to the right side, will be to 

increase and rotate left is decreasing.

Delete transmitters:

01 •

 Press the 

SEL

 button once, and the LED 

CODE

 will flash slowly.

02 •

 Press the 

SEL

 button again during 5 seconds to turn off the LED 

CODE

.

All commands have been deleted from the memory of control board.

Reset all original values of control board (reset):

01 •

 Press the 

SEL

 and 

SET

 buttons during 5 seconds until all the LEDs light on and then go off.

NOTE: 

Whenever you make a change to the potentiometer of force has necessarily form 

new programming of working time (see page 4A).

NOTE: 

Whenever you make a RESET to the control board, must turn off the soft-stop 

function that is activated by default.

01 •

 Press the 

SET

 button during 5 seconds until the LEDs 

T.R.AP

 and T.R.CH blink alternately 

and LED 

T.MOT

 keep on. This means you entered an extensive menu of control board.

02 •

 Press the 

SEL

 button until the LED 

T.MOT

 blinks and press the SET button. 

03 •

 By pressing the 

SET

 button, the LED 

T.MOT

 will turn off (off soft stop). 

Wait about 20 seconds until the control board get out automatically from the extensive 

menu where you are or turn off the power to the control board and reconnect for this out 

the extensive menu.

DELETE TRANSMITTERS AND DEFINITIONS OF CONTROL BOARD