6A5
EN
POTENTIOMETERS
05. CONFIGURATION
Power and sensitivity potentiometer adjustment:
Power potentiometer controls the power and speed of motor when opening and closing.
Sensitivity potentiometer controls the sensitivity of control board in detecting obstacles. The more sen-
sitivity the control board, the faster will detect any obstacle along the way and reverse the direction of
motor operation.
01 •
To adjust the potentiometers, just turn them with a small key. Turning to the right side, will be to
increase and rotate left is decreasing.
Delete transmitters:
01 •
Press the
SEL
button once, and the LED
CODE
will flash slowly.
02 •
Press the
SEL
button again during 5 seconds to turn off the LED
CODE
.
All commands have been deleted from the memory of control board.
Reset all original values of control board (reset):
01 •
Press the
SEL
and
SET
buttons during 5 seconds until all the LEDs light on and then go off.
NOTE:
Whenever you make a change to the potentiometer of force has necessarily form
new programming of working time (see page 4A).
NOTE:
Whenever you make a RESET to the control board, must turn off the soft-stop
function that is activated by default.
01 •
Press the
SET
button during 5 seconds until the LEDs
T.R.AP
and T.R.CH blink alternately
and LED
T.MOT
keep on. This means you entered an extensive menu of control board.
02 •
Press the
SEL
button until the LED
T.MOT
blinks and press the SET button.
03 •
By pressing the
SET
button, the LED
T.MOT
will turn off (off soft stop).
Wait about 20 seconds until the control board get out automatically from the extensive
menu where you are or turn off the power to the control board and reconnect for this out
the extensive menu.
DELETE TRANSMITTERS AND DEFINITIONS OF CONTROL BOARD