OTHER COMPONENTS
STRUCTURE
• Galvanized steel
DX51D +Z
03. OPERATOR
TECHNICAL CHARACTERISTICS
03. OPERATOR
PERFORMANCE DESIGNATION
We have the following performance designation approved by TECNALIA:
•
EI
- Prevents the passage of flames, hot gases and temperature transmission with water.
•
EW -
Prevents the passage of flames, hot gases and the transmission of thermal radiation
without water.
•
E
- Prevents the passage of flames and hot gases without water.
When tested with water, FLAMA´s sprinklers had the following characteristics:
• During the test, a flow rate of 60L/min was used, at a pressure of 1 bar. Each sprinkler
should operate at approximately 7,3L/min·m2.
• They must be placed 1,5m apart.
•
The distance between the fire breaker fabric/iron safe and the sprinklers is 40cm.
SAFE PROFILE INSTALLATION MEASURES
FLAMA has two models, and the installation of each model is variable due to its measurements.
See the table below:
FLAMA ST
FLAMA XL
• Transformer
230 V ~ 24 Vac
• Battery
2 Batteries in series 12 V = 24V
COFRE