3.4. Used as a link between the checked item and a tester removable probes must comply with the requirements 
according to GOST IEC 61010-031.  
3.5.  Personnel, admitted to the test bench operation must study its structure, operating conditions and these 
safety requirements. 
3.6. Operator must be safety and fire safety trained, must study the industrial hygiene requirements. 
3.7.  Voltage regulator

 

under test should be secured with the fixture on the a dielectric material made  lining 

(pad). 
3.8.

 

Do not block the ventilation slots in the side covers of the housing.

3.9. Do not allow liquid into the tester housing.  
3.10. Obey specified in the manual tester operating modes. 
 

3.11.

 

Strictly forbidden:

 

 

-

  

to operate the tester in the absence of operational documentation;

 

-

  to test the 

v

oltage regulator

 

with parameters not complying with the performance characteristics of the tester;

 

-

 

to use a single-phase without ground conductor for the power supply;

 

-

  to use the safety devices other than specified in the technical specifications;

 

-

  to change the circuit and electrical installation of the tester;

 

-

  to perform the maintenance and repair of the connected tester;

 

-

  to use dust probes reducing the dielectric strength of the insulation;

 

-

  to open the sealed housing of the tester; 

 
3.12. With a long break in operation, the tester must be disconnected from the mains.

 

 
4.

  

Maintenance.

 

 

4.1.

 

Tester does not require special maintenance.  

4.2. Periodically the routine inspection and maintenance should be carried out, which includes: 
-  dust removal from

 

the instrument panel, the control and indication board and the outer surface of the 

housing;  
-  checking of the terminals contact surfaces (especially in high-circuits) and probe connectors, their cleaning or 
replacement, if necessary; 
-  checking of the power cord and plug technical condition.

 

 

5.

 

Transportation and storage.

 

 

5.1. Transportation of the testers is carried out in any roofed of transport under the following climatic conditions: 
-  ambient temperature from - 25 to + 40 °; 
-  relative humidity – up to 80% at + 25 °. 
5.2. By aircraft transportation the testers should be placed in heated sealed compartments.

 

5.3. During handling operations should be followed the safety measures specified on the warning boards on the 
packaging.   
5.4.  Testers should be stored in a warehouse on the storage racks in their original packaging at ambient 
temperature from +5 to +40

о

С with relative humidity up to up to 80 % at 25

о

С.

 

 

5.5.

 

The storage place should be free of dust, corrosive vapors (alkaline and acid vapors), gases, and other 

harmful corrosive impurities that can damage the wire insulation and cause metals corrosion. 
5.6. Unpacked testers  are to be stored according to the following requirements: ambient air tempe25

°

С 

with relative humidity up to 80 %. 
 
 
 
 

 

Содержание VR-2200 v.2

Страница 1: ...VOLTAGE REGULATOR TESTER MOTORHERZ VR 2200 v 2 OPERATION MANUAL VR 2200 v 2 2018 ...

Страница 2: ...cations 5 1 4 Tester design 5 2 Device operation 8 2 1 Operating limitations 8 2 2 Pre operation 9 2 3 Preparing the tester to the diodes integrated control 9 2 4 The diodes integrated control 10 3 Safety measures 12 4 Maintenance 12 5 Transportation and storage 12 6 Disposal 13 7 Manufacturer warranty 13 APPENDIX A 13 APPENDIX B 14 ...

Страница 3: ...erate at vehicle system voltage 12V and 24V Functionality check of the A and B type generators of connection types terminals SIG P D DFM BSS LIN LIN2 RLO designed to operate at a vehicle system voltage 12V Сheck of drive windings circuit of regulators FIELD at current 0 5А 3А 5А 7A Functionality check of circuit of regulator excitation CHOKE DRIVE Functionality check of diode circuit of regulator ...

Страница 4: ...comparison element in which alternator voltage is compared with a reference value changing the current in the in a drive winding regulating unit if an alternator voltage is different from a reference value 1 2 5 Potential regulator defect may be contact pollution and contamination weakening of brushes hold downs mechanical and thermal components damage short circuit resistors diodes and semiconduc...

Страница 5: ...tinuous operation of the tester h 8 13 С Ingress protection IP 40 GOST 14254 14 Reliability mean time between failures h average service life years 2000 10 15 Overall dimensions mm no more than 270х160х220 16 Weight kg no more than 6 5 1 4 Tester design 1 4 1 The tester has a block structure in which has mounted electrical equipment containing the following main components power supply impulse sig...

Страница 6: ...ing A fusible safety device is mounted on the rear wall in a special holder 1 4 4 3 Fusible safety device holder is marked to indicate the rated current and type of fusible safety device The holder design eliminates access to parts of the tester which can be life threatening when replacing a fusible safety device 1 4 4 4 The temperature of the housing bottom during continuous tester operation is n...

Страница 7: ... control in drive winding circuit 14 DC VOLTS Digit al display red Digital indication of measured parameter Volt 15 FIELD Indicator green Indication drive winding circuit FIELD at current 0 5 A 3 0 A 5 0 А 7 0 А 16 SHORT BATTERY Indicator red Indication of short circuit on outputs POSITIVE and NEGATIVE 18 CHOKE DRIVE Button yellow Check mode CHOKE DRIVE of active lamp potential presence in circuit...

Страница 8: ...rcuits available for touching from the outside and the housing with the 500 V voltage not less than 2 MΩ 1 4 7 4 Electrical equipment of the test bench provides the following lockouts protection modes and indications short circuit protection short circuit light indication on terminals BATTERY POSITIVE and NEGATIVE during control check light indication upon contact of output FIELD с terminals BATTE...

Страница 9: ...o not block the ventilation slots in the side covers of the housing 2 2 5 Do not place heavy objects on the tester and the power cord 2 2 6 After storing the tester in a cold room or after transportation in winter conditions it is allowed switching the test bench on no earlier than after 3 hours of uncovered stay at room temperature 2 2 7 Prepare the a dielectric material made lining pad on which ...

Страница 10: ...e integrated control includes 6 modes of tester run А B C D Е F that can detect all of the major regulators defects 2 4 2 Make preparations for holding the tester control in accordance with article 2 3 2 4 3 Mode А Functionality check and measurements of stabilization breakdown of regulators of types А and В with vehicle system voltage 12 V 24 V 2 4 3 1 Switch a power supply by turning tumbler POW...

Страница 11: ...of circuit of regulator lamp alarm active lamp LAMP and circuit of regulator excitation CHOKE DRIVE 2 4 6 1 Connect green probe to the output LAMP and to the appropriate terminal of voltage regulator D 2 4 6 2 If regulator is usable indicator LAMP will switch on than will go off smoothly for a second 2 4 6 3 During next button press CHOKE DRIVE if circuit of regulator excitation is correct indicat...

Страница 12: ...long break in operation the tester must be disconnected from the mains 4 Maintenance 4 1 Tester does not require special maintenance 4 2 Periodically the routine inspection and maintenance should be carried out which includes dust removal from the instrument panel the control and indication board and the outer surface of the housing checking of the terminals contact surfaces especially in high cir...

Страница 13: ...t cover the tester in the presence of defects resulting from improper use broken seals of the electrical components self modification of the tester as well as deferred maintenance APPENDIX А obligatory Potential faults their causes and remedies Problem Possible cause Remedy The tester cannot power on No supply voltage Power supply is out of tester specification Safety device 2 A is broken Check th...

Страница 14: ...Field voltage regulator output FLD the same as F FR Field Reports output to control the generator load with the engine control unit L Lamp Output of the indicator light of the generator performance indication LI Load Indicator Ford the same as FR only with inversion LIN bidirectional single wire bus of the generator control and diagnostic with the LIN Local Interconnect Network interface M Monitor...

Отзывы: