CLEARING LAST FAULT
The last fault stored can be cleared on the PumpSaver®:
1.
Rotate MODE SELECT to OPT2.
2. Press and hold RESET/PROGRAM.
3.
Adjust DISPLAY/PROGRAM until “cLr” appears on the display.
4. Release
RESET/PROGRAM.
To verify the last fault was cleared, turn MODE SELECT to RUN. Press and hold
RESET/PROGRAM – “cLr” should be on the display.
TAMPER GUARD
The PumpSaver
®
can be protected from unauthorized program changes by locking the setpoints.
1.
Rotate MODE SELECT to OPT2
2.
Press and hold the RESET button. Adjust DISPLAY/PROGRAM until ”Loc” appears on the
display.
3. Release the RESET button.
4.
Turn MODE SELECT to RUN.
The program is now locked, but all settings can be viewed. The unit can be unlocked by following
the procedure above except step three; adjust DISPLAY/PROGRAM until “unL” appears.
NOTES:
1)
If a setting jumps back to its previous setpoint when changed, the tamper guard is locked.
2)
The state of the tamper guard cannot be viewed directly.