© Motor City Wash Works, Inc. 48285 Frank, Wixom Michigan 48393 U.S.A. 

Phone: 248.313.0272 

 Fax: 248. 313.0271 

        

REVISION 1.0 09-24-09

                             

www.motorcitywashworks.com

                                                 

1

 

          SINGLE WANNER PUMP PREP UNIT INSTALLATION MANUAL 

                      Part # HPPREPSYSTEM004 

 

 

 

 

 

 

 

  TABLE OF CONTENTS

 

 
Equipment Specifications

                

 

                                                                                     

Page:  1  

Suggested Tools and Installation Materials

   

 

                                                                            

Page:  2  

Installation Instructions

                                                                                                      

Page:  3  

Start-Up Procedures

                                                                                                                 

Page:  3 

Maintenance

                                                                                                                   

Page:  5 

 

  Equipment Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    Equipment  Features   

                 

 

 

 

 

This 

Wanner High Pressure Pumping Station 

has one pump on a single frame. The pump will 

deliver about 

9 GPM @ 900 PSI (34.1 LPM @ 6.21 MPa). 

 This pump is capable of delivering 

fresh water as well as filtered reclaim water.  Typically used as a prep station, this unit uses one 

Wanner D10 Hydra-Cell Pumps 

and is belt-driven by a

 7 1/2HP electrical motor.

  

 

 

    Suggested Installation Tools and Materials 

 

                  

 

 
 
 
 

5

 

 

 

 Hammer Drill with 3/8” Drill Bit 

…

     (8) Wedge Anchor Bolts 3/8” x 4” 

…

 

Sledge Hammer

 

…

     

Safety Goggles 

…

 

Set of Standard Combo Wrenches 

…

     

Torpedo Level 

…

 

Measuring Tape 

…

     

Safety Goggles 

 

    Notes and safety Symbols 

 

                  

 

 

Where necessary, important points will be highlighted in this manual, using the following symbols: 

 
 

NOTE: 

PROVIDES FURTHER INFORMATION!

 

 
 
 

 

PREP UNIT 

HPPREPSYSTEM004 

DIMENSIONS 

UNIT LENGTH 

45 IN  

 UNIT WIDTH 

34 IN 

UNIT HEIGHT 

30 IN  

UNIT WEIGHT 

500 LBS 

ELECTRICAL 

 7 1/2 HP 3-phase 208-230/460 VAC 

23.3-21/10.5 AMPS 

PNEUMATICS N/A 

WATER 

9 GPM @ 900 PSI 

Содержание Wanner HPPREPSYSTEM004

Страница 1: ...This pump is capable of delivering fresh water as well as filtered reclaim water Typically used as a prep station this unit uses one Wanner D10 Hydra Cell Pumps and is belt driven by a 7 1 2HP electrical motor Suggested Installation Tools and Materials 5 Hammer Drill with 3 8 Drill Bit 8 Wedge Anchor Bolts 3 8 x 4 Sledge Hammer Safety Goggles Set of Standard Combo Wrenches Torpedo Level Measuring ...

Страница 2: ...ed for your protection Review thoroughly with all personnel WARNING NEVER ATTEMPT TO WORK ON THE EQUIPMENT WHILE IT IS RUNNING PERSONNEL MUST BE TRAINED IN SAFE OPERATING PROCEDURES ALL PERSONNEL SHOULD REVIEW THIS MANUAL PERIODICALLY EMERGENCY STOP BUTTONS MUST BE WELL MARKED AND THEIR LOCATION AND OPERATION REVIEWED WITH ALL PERSONNEL MAINTENANCE OR REPAIR WORK ON EQUIPMENT MUST BE PERFORMED ONL...

Страница 3: ...xceed 140o F B Before starting the Pump make sure that all connections are tight and that the discharge system is open C Check for oil in pump Level should be 1 from top D Turn the unit on keeping hands and loose clothing away from unit at all times Allow unit to run for at least 2 minutes E Turn adjusting bolt CW to desired pressure by reading gauge Refer to page 1 for your unit operating pressur...

Страница 4: ...HARMFUL IN THE EVENT OF OVERSPRAY ONTO SOMEONE 8 If pump is located where temperature might drop below 45 F use S A E 5W30 oil in pump Maintenance Schedule Trouble Shooting Chart Trouble Possible Cause Probable Remedy Excess pressure required to bypass fluid Regulator not properly adjusted Check pressure and set regulator accordingly Not enough fluid being bypassed Ensure reservoir is being suppli...

Страница 5: ... defective with a new or refurbished unit not to include costs of removal or installation Any product returned to MCWW for warranty has to have a Return Material Authorization Number All shipping costs to MCWW are assumed by the customer This is only a summary of MCWW s Limited Warranty Please communicate with MCWW for our complete warranty Prior to returning any product to MCWW the customer must ...

Отзывы: