    Installation Instructions                  

 

 

 

 

 

 

Open

  all  boxes  and  crates  and  verify  that  you  have  all  the  required  components  as  well  as  all  your 

installation  material.  Your  anti-collision  system  comes  with  a  control  box  (see  Picture  #1),  15FT  of  3/4” 
liquid tight flexible conduit, one end cap and a 18mm vehicle sensor with 30FT cord (Picture #2). 

 
                                 

REMOTESTOP0001

SYSTEM OK

8DCALREMSTP0001

POWER

WASH WORKS

R

M

C I T Y

T

0

MOTOR CITY WASH WORKS

UNIVERSAL HAND HELD

REMOTE STOP SYSTEM

STOPPED

PUSH

TO

RESTART

* US E REMOTE STOP TO TURN OFF
  CO NVEYOR OR WA SH EQUIPMENT
  WHEN NEEDED.
* THE MCWW UNIVERSAL REMOTE STOP
  CA NNOT REPLACE EMERGENCY
  STOP BUTTONS. INSTALL
  REA DILY AVAILABLE  EMERGENCY STOP
  BUTTO NS ON EACH SIDE OF THE
  WASH BAY.
* WHENEVER AN EMERGENCY STOP
  BUTTO N IS PUSHED, IT IS TO  BE
  RE SET ONLY BY THE PE RSON WHO
  INITIALLY STOP PED THE EQUIPMENT
  AFTER THE E MERGENCY.

FAI LURE TO  FOLLOW THESE RULES

M AY LEADS TO  EQUI PMENT  DAMAGES,

PERSONAL INJURI ES OR DEATH!

DANGER!

7ELECHASTRS0001

7CONVELCPNL0001

                

Picture #1: Control Box w/Remote Transmitters 

 
 

 

Mount 

the electrical control box (7CONVELCPNL0001) in a dry area in the mechanical room and in close 

proximity to the center of the wash bay (you will need to install the antenna assembly in the middle of the 
wash bay, on the mechanical room wall and connect it to the control box). 
 

 

Mount 

the antenna assembly in the middle of the wash bay, on the mechanical room wall and about 10ft 

off of the floor and connect it to the control box located in the mechanical room. 

 

 

Picture #2: Antenna Assembly 

 

 

Connect 

the control box to a 120VAC, 1PH separate breaker circuit from the building 120VAC sub-panel 

(lighting panel). 

 
 

CABLE CONNECTOR 

7ELECHARTRS0001

 