    Possible Problems/Remedies

 

 

 

Equipment: 

Problem: 

Remedy: 

HP Blaster Arches   

Not turning on. 

Verify run command 

to motor starter/soft 
start/VFD. 
 
Check for fault on soft 
start/VFD. 
 
 

HP Blaster Arches   

Pump motor turns on, 
but low pressure. 

Verify motor box 
wiring is correct for 
your site voltage. 
 
Verify belt tension. 
 
Pressure regulator is 
not set correctly or 
there is a blockage. 

HP Blaster Arches   

Water not flowing 
through all nozzles. 

Check for individual 
clogged nozzle 
screens. 
 
Ensure good incoming 
water pressure. 
 
Check main water 
filter is not clogged 
and is flowing the 
correct direction. 

HP Blaster Arches   

Run command 
present but no water 
flowing to nozzles. 

Check incoming 
power is present at 
motor control. 
 
Ensure no tripped 

Содержание 7AXISAIRPNL0002

Страница 1: ...Slot From the Floor the Height is 4 3 16 H Slot Length is 10 L Traveling Distance is 5 1 2 Integrated Aluminum H2O Filter Integrated Pneumatic Air Cylinder Mechanically Pivots the Manifold Three Posit...

Страница 2: ...ng equipment and or the safety of the people working on the equipment Instructions for Pivoting Wheel Blaster Air Panel Open all boxes and crates to verify that you have all the required components an...

Страница 3: ...Motor City Wash Works Inc 48285 Frank Wixom Michigan 48393 U S A Phone 248 313 0272 Fax 248 313 0271 8MANULWPBRINS01 11 18 20 REV 1 0 www motorcitywashworks com 3 Driver s Side Passenger s Side...

Страница 4: ...air line instruction 1 4 OD polyflow tubing is required to complete this step Follow the plumbing to ensure proper air cylinder operation PORT 2 4 THE SOLENOID VALVE PORT 2 RESPONSIBLE FOR RETRACTING...

Страница 5: ...Loosen the bolts to allow for up and down movement Tighten the two bolts after you find your desired height Banjo fittings are located on the top of the air cylinder These tune the speed of the pivot...

Страница 6: ...UL OF YOUR SURROUNDINGS AND NEVER STAND DIRECTLY IN FRONT OF THE UNIT DURING OPERATION Maintenance Your Pivoting Wheel Blaster requires the following maintenance 1 The aluminum H2O filter requires per...

Страница 7: ...Motor City Wash Works Inc 48285 Frank Wixom Michigan 48393 U S A Phone 248 313 0272 Fax 248 313 0271 8MANULWPBRINS01 11 18 20 REV 1 0 www motorcitywashworks com 7...

Страница 8: ...Motor City Wash Works Inc 48285 Frank Wixom Michigan 48393 U S A Phone 248 313 0272 Fax 248 313 0271 8MANULWPBRINS01 11 18 20 REV 1 0 www motorcitywashworks com 8...

Страница 9: ...Motor City Wash Works Inc 48285 Frank Wixom Michigan 48393 U S A Phone 248 313 0272 Fax 248 313 0271 8MANULWPBRINS01 11 18 20 REV 1 0 www motorcitywashworks com 9...

Страница 10: ...Motor City Wash Works Inc 48285 Frank Wixom Michigan 48393 U S A Phone 248 313 0272 Fax 248 313 0271 8MANULWPBRINS01 11 18 20 REV 1 0 www motorcitywashworks com 10...

Страница 11: ...Motor City Wash Works Inc 48285 Frank Wixom Michigan 48393 U S A Phone 248 313 0272 Fax 248 313 0271 8MANULWPBRINS01 11 18 20 REV 1 0 www motorcitywashworks com 11...

Страница 12: ...Motor City Wash Works Inc 48285 Frank Wixom Michigan 48393 U S A Phone 248 313 0272 Fax 248 313 0271 8MANULWPBRINS01 11 18 20 REV 1 0 www motorcitywashworks com 12...

Страница 13: ...Motor City Wash Works Inc 48285 Frank Wixom Michigan 48393 U S A Phone 248 313 0272 Fax 248 313 0271 8MANULWPBRINS01 11 18 20 REV 1 0 www motorcitywashworks com 13...

Страница 14: ...a problem in order to solve it and make the product or process operational again It is imperative to understand that all problems have a cause and solution Many times you may not have an actual fault...

Страница 15: ...laster Arches Pump motor turns on but low pressure Verify motor box wiring is correct for your site voltage Verify belt tension Pressure regulator is not set correctly or there is a blockage HP Blaste...

Страница 16: ...is present at motor junction box Ensure belt is driving pump Check main water filter is not clogged and is flowing the correct direction HP Blaster Arches HP nozzle not rotating Check main water filte...

Страница 17: ...or replace this product if found defective with a new or refurbished unit but not to include costs of removal or installation Any product returned to MCWW for warranty has to have a Return Material A...

Отзывы: