KEY PARTS DIAGRAM
5
model no. 011-2047-2 | contact us : 1-877-466-8191
6
KEY PARTS DIAGRAM
Front Panel
Rear Panel
• ON/OFF Switch — This switch controls AC output of the inverter.
• Power LED (Green) — When this green LED is lit, the inverter is operating normally.
• Ground Fault LED (Yellow) — When the yellow LED is lit, the ground fault circuit has
been activated. Shut down the inverter and restart.
• Fault LED (Red) — The RED indicator turns on as the inverter shuts down due to
overheating, overload, under voltage, over voltage, short circuit or current leakage
protection.
Caution: For short circuit protection, it will be automatically recovered within 5 times,
but after 5 times, need to be resettled manually.
a. Immediately turn off all AC appliances if the FAULT LED is lit. Allow the inverter to
cool before continuing. Make sure that the ventilation vents are not blocked.
b. If an inverter shutdown was preceded by a buzzing sound, there may be an
excessive load in combination with a low voltage or cable problem.
c. Normal operating range is 11 V to 15 V DC.
• USB Power Port — This power port can supply 5 volts at 2.1 A for charging or powering
tablets, e-readers, smart phones, and other small electronic devices.
• Audible Alarm (internal to the inverter) — When the Audible Alarm makes a buzzing
sound, the inverter senses a low battery condition. The user should reduce the AC load,
charge the battery, and check the DC cable for excessive losses.
• Positive Terminal — Positive (+) DC Input (Red)
• Negative Terminal — Negative (−) DC Input (Black)
• Cooling Fan — High-speed and temperature controlled
• Ground Terminal — For attaching an insulated safety ground wire. This safety wire is
for protecting personnel if there is an unlikely failure in either the cabling or enclosure
insulation. Grounding the inverter enclosure ensures personnel safety should a DC
cable problem occur. During the installation procedure, the Ground Terminal is
connected either to a vehicle chassis or to the negative DC terminal of the battery. Do
not directly connect this ground connection to the negative DC terminal of the inverter.
Use an insulated 12 gauge wire to make the ground connection. If the inverter
installation is located in a fixed location, the safety wire can be grounded.
4
5
1
2
3
6
1. Power LED
2. Ground Fault LED
3. Fault LED
4. Two 115 V AC Outlets
5. USB Port (5 V,2.1 A)
6. ON/OFF Switch (I/O)
7
8
10
9
7. Positive (+) DC Input Terminal
8. Negative (–) DC Input Terminal
9. Ground Terminal
10. High Speed Cooling Fan