1. Sensor (black wire)
2. Sensor signal - (grey wire)
3. Heater ground connection (white)
4. Heater power supply (white)
AXONE: PARAMETERS
Lambda probe
Example value: 0 - 1000 mV
If there is a short circuit at + 5 V or above, the value read is approx. 5.000 mV. If there is a short circuit
to ground instead, the value read is equal to 0 mV and the Lambda Sensor Correction parameter shows
25%: no error is displayed, though.
Lambda sensor correction
Example value: 1.00
In closed loop, the value must be close to 0 % (values not within the +10 % and -10 % range may
indicate a fault): In an open circuit, the lambda probe signal is too low. Therefore, the control unit takes
it as a lean mixture condition and will try to enrich it. The value read will be +25%.
AXONE: STATUSES
Lambda check
Example value:
Open loop / Closed loop
Closed loop indicates that the control unit is using the lambda probe signal to keep the combustion as
close as possible to the stoichiometric value.
AXONE: ELECTRICAL ERRORS
Lambda probe P0130
- shorted to positive.
Error cause
•
Excessive voltage (battery voltage) has been detected at PINS 32 and 22 of the BLUE
connector.
Troubleshooting
•
if shorted to positive: with the key set to ON, disconnect the sensor connector and measure
voltage at PIN 1 on the cable harness side (white/yellow cable): if there is voltage (5 or 12
V), restore the cable harness; it there is no voltage, measure voltage at PIN 2, cable harness
side, (green/white cable) and if there is voltage, restore the cable harness; if there is no
voltage, replace the lambda probe
Lambda probe heating P0135 -
shorted to positive / open circuit, shorted to negative.
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 11 of the BLUE connector.
•
If the circuit is open, shorted to negative: voltage equal to zero has been detected at PIN 11
of the BLUE connector
Troubleshooting
GRISO 8V - 1200
Electrical system
ELE SYS - 65
Revente Interdite - Revendita Vietata - Resaling Forbiden - Wiederverkauf Verboten
Содержание Griso1200 8V
Страница 1: ...SERVICE STATION MANUAL 854378 GRISO 8V 1200 ...
Страница 4: ...Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 30: ...INDEX OF TOPICS MAINTENANCE MAIN Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 41: ...GRISO 8V 1200 Maintenance MAIN 41 Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 93: ...INDEX OF TOPICS ENGINE ENG Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 175: ...INDEX OF TOPICS POWER SUPPLY P SUPP Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 186: ...INDEX OF TOPICS SUSPENSIONS SUSP Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 212: ...INDEX OF TOPICS CHASSIS CHAS Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 242: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 252: ...INDEX OF TOPICS CLUTCH SYSTEM CLU SYS Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 254: ...INDEX OF TOPICS BODYWORK BODYW Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...
Страница 261: ...INDEX OF TOPICS PRE DELIVERY PRE DE Revente Interdite Revendita Vietata Resaling Forbiden Wiederverkauf Verboten ...