SM100 Series 

Instruction Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WWW.MOTIC.COM

 

 

MOTIC HONG KONG LIMITED

 

Содержание SWIFTLINE SM100 Series

Страница 1: ...SM100 Series Instruction Manual WWW MOTIC COM MOTIC HONG KONG LIMITED...

Страница 2: ...three dimensional image with a large comfortable field of view The SM100 Series incorporates features to enhance and provide maximum versatility for classroom and professional use It is built to rigi...

Страница 3: ...ottom 5W LED Corded Stand Turret variable 6 x 06W LED Top variable 5W Bottom 5W LED Corded Stand SM100 CORDLESS SERIES STEREO MICROSCOPE SPECIFICATIONS Model Number SM101 C SM102 C SM105 C Objectives...

Страница 4: ...Clips Stage Plate SM105 C Pictured Bottom Illuminator Top Turret Angled Illuminators Illuminator Dimmer Control Illuminator On Off Switches Eyepiece Eyepiece tube Diopter Adjustment Power Switch Stan...

Страница 5: ...tem which prevents the head from traveling past both ends of the focusing range When the focusing limit is reached the clutch system begins to slip to prevent gear damage HEAD The 360 rotatable compon...

Страница 6: ...ottom Illuminators TOP ANGLED ILLUMINATOR The top 5W LED light source is fixed at a 45 angle TOP TURRET ILLUMINATOR The top 6 x 06W LED light source is fixed in a downward in a vertical position to pr...

Страница 7: ...is now parfocalled SERVICE AND CLEANING Use and store your instrument in a dry environment When not being used microscopes should be stored with dust covers in place and illuminators turned off Avoid...

Страница 8: ...handle screw driver They can then be unclipped and replaced See Fig 2 The transmitted bottom illumination bulb is Swift MA14782 3 5V 150mA LED Bulb The bottom bulb may be replaced by carefully laying...

Страница 9: ...gital camera such as the Moticam The purchase of an optional C mount camera lens is necessary for the conversion MA15604 DO NOT PLUG INTO USB PORT OF MICROSCOPE 1 First take your Moticam camera and re...

Страница 10: ...ol is set above 0 3 The bulb may need to be replaced See Bulb replacement on page 8 B PROBLEM Unable to bring specimen into focus CORRECTION 1 Eye lens of the eyepiece is partially unscrewed Remove th...

Страница 11: ...ulb Top illuminator MA14781 3 5V 150mA LED Bulb Arm illuminator MA14782 3 5V 150mA LED Bulb Bottom illuminator MA14281 Power supply converter 100 240VAC in 4 5VDC 1a out MA15604 C Mount Adapter MA1902...

Страница 12: ...Deutschland GmbH GERMANY Christian Kremp Strasse 11 D 35578 Wetzlar Germany Tel 49 6441 210 010 Fax 49 6441 210 0122 Motic Europe SPAIN C Les Corts 12 Pol Ind Les Corts 08349 Cabrera de Mar Barcelona...