
With Hall Sensor Type
With Potentiometer Type
With Limit Switch Type
● Please refer to the table below to define the actuator's extension. When
Red (M+) is connected to "+" and Black (M-) is connected to "-" of DC
power, the actuator will extend.
● White, Yellow & Blue are positioning signal wires as shown in table.
● The resistance between Blue and White wires increases when extending,
and decreases when retracting.
● Please refer to the table below to define the actuator's extension. When
Red (M+) is connected to "+" and Black (M-) is connected to "-" of DC
power, the actuator will extend.
● Please refer to the table below to define the actuator's extension.
When Red (M+) is connected to "+" and Black (M-) is connected to "-" of DC
power, the actuator will extend.
● White, Yellow & Blue are positioning signal wires as shown in table.
● The resistance between Blue and Yellow wires increases when extending,
and decreases when retracting.
● Signal resolution
:
20PPI, 1.27mm/pulse (0.787 pulses/mm)
M1-FAM-I-0001-1.3
© 2018 Motec
k. Printed in Taiwan. The contents of this publication are the copyright of the publisher and may not be copied or
even extracted unless prior written
permission is authorized.
SAFETY DECLARATION
This appliance cannot be used by children or persons with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction.
Power
Red
Black
M+
M-
White
Yellow
Blue
VCC
Data
GND
Signal
Power
Red
Black
M+
M-
Actuator extends
Y
W
B
W
B
Y
254
0.3 ~ 7.4
K
Stroke (mm)
Resistance (tolerance: ±0.3KΩ)
305
0.3 ~ 8.8K
610
0.3 ~ 9.8K
Power
Red
Black
M+
M-
White
Yellow
Blue
GND
VCC
Data
Signal
102
0.3 ~ 8.1K
153
0.3 ~ 8.7K
203
0.3 ~ 9.2K
457
0.3 ~ 9.4K