68
Part Number: 000016427 Rev 00 08/2020
ICE MACHINE CYCLES INTO HARVEST BEFORE WATER CONTACT WITH THE ICE
THICKNESS PROBE
Step 1
Bypass the freeze time lock-in feature by moving the ON/OFF/WASH switch to
OFF and back to ON. Wait until the water starts to flow over the evaporator, then monitor
the harvest light.
Step 2
Disconnect the ice thickness probe from the control board terminal.
ICE THICKNESS
PROBE
DISCONNECT
PROBE WIRE
BIN SWITCH
LIGHT (GREEN) HARVEST LIGHT
(RED)
SV1592J_2
Step 2 Disconnect probe from control board terminal
Monitoring Harvest Light
Correction
The harvest light stays off and the ice
machine remains in the freeze sequence.
The ice thickness probe is causing the
malfunction. Verify that the ice thickness
probe is adjusted correctly.
The harvest light comes on, and 6-10
seconds later, the ice machine cycles from
freeze to harvest.
The control board is causing the
malfunction.