GAS SUPPLY AND BURNER INFORMATION
Supply pressure should be a
minimum
of 6” Water Column for Natural Gas and 12” Water Column
for Propane. The fryer comes with ¾” NPT male connector on a ½” pipe, allowing you to connect
with either a ¾” or ½” NPT female connector.
Model
Gas Type
Manifold
Pressure
Number of
heat tubes
BTU Rate
per
Burner
Total BTU
Rating
Orifice
Size
MGF3-N
NATURAL
4” W.C.
3
30,000
90,000
#39
MGF3-P
PROPANE
10” W.C.
3
30,000
90,000
#52
MGF4-N
NATURAL
4” W.C.
4
30,000
120,000
#39
MGF4-P
PROPANE
10” W.C.
4
30,000
120,000
#52
MGF5-N
NATURAL
4” W.C.
5
30,000
150,000
#39
MGF5-P
PROPANE
10” W.C.
5
30,000
150,000
#52
Minimum supply pressure is 6" W.C. for natural gas and 12" W.C. for propane.
Orifice sizes are for units installed at altitudes between 0 and 2000 feet above sea level.
Installation
Step #1: Unpack
**IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has
assumed responsibility for safe transit and delivery. If damaged equipment is received, either apparent or
concealed, a claim must be made with the delivering carrier.
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then
be signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim.
The carrier can supply the necessary forms.
A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss
that is not apparent until after the equipment is uncrated. The carrier should arrange an inspection.
Be certain to hold all contents plus all packing material.
1. Uncrate carefully. Report any hidden damage to the freight carrier IMMEDIATELY.
2. Do not remove any tags or labels until unit is installed and working properly.
Installation must conform with local codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane
Installation Code, CAN/CGA-B149.2, as applicable.
These installation procedures must be followed by qualified personnel or warranty will be void.
Local codes regarding installation vary greatly from one area to another. The National Fire Protection
Association, Inc. states in its NFPA 96 latest edition that local
codes are the “authority having jurisdiction”
when it comes to installation requirements for equipment.
WARNING:
MAXIMUM INCOMING PRESSURE CANNOT EXCEED ½ P.S.I. OR 13” WATER COLUMN
DAMAGE CAN AND WILL RESULT IF PRESSURE IS EXCEEDED!