7
POWER AND GROUND CONNECTIONS
WARNING
: ELECTRIC SHOCK HAZARD. All power connections must be connected or
covered. Failure to do so will expose operators to possible shock and the
possibility of grounding-out or shorting-out of the test power source.
All power connections must be covered or connected. Failure to do so will allow applied
voltages to be present on exposed metal parts of the connectors. Operators could receive
an electrical shock if they come in contact with these exposed conductors. If a loose
conductor contacts an exposed metal part of a “hot” receptacle, it could lead to
grounding-out or shorting-out of the source generator.
WARNING
: ELECTRIC SHOCK HAZARD. The grounding lug must be connected to earth
ground. Operating without a grounding connection could lead to injury or
death.
When the Heater is in operation the grounding cam must be firmly and electrically
connected to earth ground. Failure to do so could allow deadly voltage to be present on
the surface of the enclosure. The grounding connection provides a low resistance path to
ground. This grounding protects the operator from the possibility of electrical shock.
AIR INTAKES AND EXHAUST PORTS
CAUTION
: All air intakes and exhaust ports must be clear and fully open. Each Heater
has one or more air intakes designed for proper air flow. Reducing or blocking
air flow will lead to overheating and Heater failure.
Customer Cam-Lock
Connections
Ground
Cam
2