Mosa DS-512400 Скачать руководство пользователя страница 6

 

 

- 5 - 

 

2

 

G

ENERAL 

I

NFORMATION

 

 

 

Model/Parameters  

LS-512400 

LS-512460 

Basic 

 

Normal Voltage [V] 

51.2 

51.2 

Normal Capacity [Ah] 

400 

460 

Operating Voltage [V] 

40~58.4 

40~58.4 

Rated energy [kWh] 

20.4 

23.5 

Battery Type 

Li-on

LiFePO4

 

Li-on

LiFePO4

 

Ah Efficiency [%] 

99.5 

99.5 

Wh Efficiency [%] 

96 

96 

Standard Power [kW] 

20 

20 

Recommended Charging current [A] 

200 

200 

Maximum Discharging current [A] 

400 

400 

Dimension & Weight 

Dimension(L*W*H) [mm] 

750*460*320 

750*460*320 

Weight [Kg] 

170 

190 

Communication

 

Battery to Inverter 

RS485/CAN 2.0 

Battery to Battery/BMS 

RS485 

Capacity Indicator 

4LED (25%, 50%, 75%, 100%) & LCD Screen 

Switch ON/OFF 

Button 

Environment

 

Operating Temperature [

-10 to 55 

-10 to 55 

Relative Humidity [%] 

5 to 95 

5 to 95 

Altitude [m] 

Below 4000 

Below 4000 

Standard Comply

 

Safety 

CE, ROHS 

CE, ROHS 

Hazardous Materials Classification 

Class 9/UN3480 

Class 9/UN3480 

Transport Testing Requirement 

UN38.3 

UN38.3 

Cycle Life [85% DOD] 

 5000  

 5000  

Warranty [Year] 

Содержание DS-512400

Страница 1: ...LITHIUM ION BATTERY PRODUCT USER MANUAL DS 512400 DS 512460 INDUSTRIAL...

Страница 2: ...1 REVISION RECORDS NO Revision Author Revision Of Content Revision Time 1 V1 0 First Release 07 24 2022 2 3 4 5...

Страница 3: ...Panel features Introduce the interface function 4 Packing list Packing list 5 Installation Installation and operation 6 Shipping Storage and Disposal Shipping Storage Maintenance And Disposal BEFORE...

Страница 4: ...the battery incorrect installation using the battery may cause personal injury or damage to the product 1 DO NOT throw the battery into water Store batteries in cool and dry environment when not in u...

Страница 5: ...d or disassembled 9 Batteries are half charged before shipment Don t use the battery if it s hot bulge or smell abnormal and so on and report to after sale dept immediately 10 If you need storage the...

Страница 6: ...urrent A 400 400 Dimension Weight Dimension L W H mm 750 460 320 750 460 320 Weight Kg 170 190 Communication Battery to Inverter RS485 CAN 2 0 Battery to Battery BMS RS485 Capacity Indicator 4LED 25 5...

Страница 7: ...he BMS 3 ID Assign address of every model See Table 3 4 4 CAN CAN Communication interface 5 RESET 6 Battery Comm RS485 Battery inter comm when connect in parallel 7 Terminals Positive 8 Terminals Nega...

Страница 8: ...face definition Pin No Definition Pin No Definition PIN 1 NC PIN 5 CAN CAN_L PIN 2 NC PIN 6 NC PIN 3 NC PIN 7 NC PIN 4 CAN CAN_H PIN 8 NC CAN_H CAN_L RS485 Communication interface definition Pin No De...

Страница 9: ...8 4 PACKING LIST Parts List Item Item name Qty 1 DS 51200 R01 battery module 1 2 Power cable between battery and Inverter MPC 400A 600V 75mm _1m 2 3 Communication cable_1m 1 4 User manual 1 5 Carton 1...

Страница 10: ...h the battery system is in good condition and free from defects 2 Before installation make sure that the power supply system is under shut down state while the battery system is also under shut down s...

Страница 11: ...ete if any damaged please fill in the receipt 3 Please be careful while handling batteries avoid any damage Installation The battery is rack installed steps shows below CAUTIONS When begin to install...

Страница 12: ...ry module to parallel Set the ID following the ID arrangement table Connect the power cable in parallel by power cables and connect communication cables in battery comm interface with communication ca...

Страница 13: ...ree of alkaline acidic substances and other corrosive gases without a strong mechanical vibration shock and without strong electromagnetic field and direct sunlight Capacity was maintained at 50 to 60...

Отзывы: