background image

13

Mortex Products, Inc. / FT. WORTH, TX 76106  

G17 / G18 Installation Instructions  

Printed 04/04

12

Mortex Products, Inc. / FT. WORTH, TX 76106  

G17 / G18 Installation Instructions  

Printed 04/04

INSTALLATION INSTRUCTIONS

WARNING

ELECTRIC SHOCK HAZARD

Disconnect all electric power

before servicing.

1. Incoming wire must be polarized. Observe color coding.
2. If any of the original wires must be replaced, use 105C 

Thermoplastic type wire or its equivalent.

3. **RED** = Lo Speed - 4 Speed Motor Only

GAS, PILOT, ATMOSPHERIC FURNACE
MODELS G17D060, G17D070

P/N 61GFC003  

Mortex Products, Inc. / FT. WORTH, TX 76016

WARNING

ELECTRIC SHOCK HAZARD

Disconnect all electric power

before servicing.

1. Incoming wire must be polarized. Observe color coding.
2. If any of the original wires must be replaced, use 105C 

Thermoplastic type wire or its equivalent.

3. **RED** = Lo Speed - 4 Speed Motor Only

GAS, PILOT, ATMOSPHERIC FURNACE
A/C READY - MODELS G17D060, G17D070

P/N 61GFC004  

Mortex Products, Inc.

FT. WORTH, TX 76016

H 2/10, 1/4 HP, 2 SPD BLOWER -
HEATING SPEED SELECTION

G17D060, G17D070 LO OR HI SPEED TAP

FIG. N - G17D060, G17D070 - W/PILOT, HEATING

FIG. O - G17D060B, G17D070B - W/PILOT, A/C READY

FIG. Q - G17D090B - W/PILOT, A/C READY

FIG. P - G17D090 - W/PILOT, HEATING

WARNING

ELECTRIC SHOCK HAZARD

Disconnect all electric power

before servicing.

1. Incoming wire must be polarized. Observe color coding.
2. If any of the original wires must be replaced, use 105C 

Thermoplastic type wire or its equivalent.

3. **RED** = Lo Speed - 4 Speed Motor Only

GAS, PILOT, W/ COMBUSTION BLOWER
A/C READY - MODEL G17D090

P/N 61GF0006

Mortex Products, Inc. / FT. WORTH, TX 76016

WARNING

ELECTRIC SHOCK HAZARD

Disconnect all electric power

before servicing.

1. Incoming wire must be polarized. Observe color coding.
2. If any of the original wires must be replaced, use 105C 

Thermoplastic type wire or its equivalent.

3. **RED** = Lo Speed - 4 Speed Motor Only

GAS, PILOT, W/ COMBUSTION BLOWER
HEATING - MODEL G17D090

P/N 61GFC005

Mortex Products, Inc. / FT. WORTH, TX 76016

WIRING DIAGRAMS

WIRING DIAGRAMS

Содержание G17D

Страница 1: ...th a cooling unit the furnace shall be installed parallel with or on the upstream side of the cooling unit to avoid condensation in the heat exchanger For installations with a parallel flow arrangement the furnace must be equipped with a damper or other means to prevent cold air from being discharged up around the heat exchanger GAS VALVE CONVERSION INSTRUCTIONS 1 Follow instructions TO TURN OFF G...

Страница 2: ...n 6 PART NO DESCRIPTION NOTES 90 RJF1729 AL Body Roof Jack Gas FLAT Height A 73 in 85 in 90 RJF2551 AL Body Roof Jack Gas FLAT Height A 81 in 107 in 90 RJS1729 AL Body Roof Jack Gas SLOPE 3 12 Height B 81 in 101 in 90 RJS2551 AL Body Roof Jack Gas SLOPE 3 12 Height B 97 in 123 in 90 RJS3868 AL Body Roof Jack Gas SLOPE 3 12 Height B 110 in 140 in 90 RJS6399 AL Body Roof Jack Gas SLOPE 3 12 Height B...

Страница 3: ...stem have a flame spread classification of 200 or less 6 Non combustible pans having one inch upturned flanges are located beneath openings in the floor return duct system 7 Wiring materials located in the return duct system conform to Article 300 22 B C of the National Electric Code ANSI NFPA 70 8 Gas piping is not run in or through the return duct system 9 The negative pressure in the closet as ...

Страница 4: ...ng above the floor Bend sides over onto the floor surface Fig F 8 Install floor base over floor opening with 13x13 flanges down Nail to floor thru 4 holes Fig G INSTALL FURNACE Prior to installing furnace fuel and A C line openings may be cut in See FIG D 1 Remove upper and lower furnace doors 2 Slide furnace onto floor base and push back until cabinet is against rear flange of floor base 3 Secure...

Страница 5: ...es gas line connection point To furnace gas control valve To furnace wall thermostat 4 Upper crown in original carton must be stored in a prominent location inside the home until crown installation is made at site location AT MANUFACTURED HOME SITE 5 The transit weather cap is removed and 6 90 RJCRWN AL crown installed per these instructions See FIG K Make sure crown engages RJ body pipes above th...

Страница 6: ...ator on the gas control valve must also be converted See label on lower furnace compartment for full instructions If the gas input to the furnace is too high due to excessive gas pressure wrong size burner orifice no orifice high altitude etc the burner flame will be sooty especially with Propane gas This type of furnace operation can produce carbon monoxide which could result in unsafe operation ...

Страница 7: ...ADY MODELS G17D060 G17D070 P N 61GFC004 Mortex Products Inc FT WORTH TX 76016 H 2 10 1 4 HP 2 SPD BLOWER HEATING SPEED SELECTION G17D060 G17D070 LO OR HI SPEED TAP FIG N G17D060 G17D070 W PILOT HEATING FIG O G17D060B G17D070B W PILOT A C READY FIG Q G17D090B W PILOT A C READY FIG P G17D090 W PILOT HEATING WARNING ELECTRIC SHOCK HAZARD Disconnect all electric power before servicing 1 Incoming wire ...

Страница 8: ... R68CA0005 R86GF0050 R86GF0050 R68GF0001 R68GF0006 R68GF0007 R68BKN007 R86GF0051 R86GF0052 R68GF0004 R68DD0009 R68DD0009 R68DD0008 R68GF0002 R68CA0004 R86GF0053 R86GF0054 R86GF0054 R68GF0005 R76AA0002 R86GF0055 R86GF0123 R86GF0119 R65GF0001 R65GF0002 R65GF0003 R86GF0056 R68DE0001 R68DE0002 R68DE0003 R69AB0001 R68AB0002 R68AB0002 R68CA0007 R68CA0006 R68GF0009 R68GF0008 R86GF0057 R86GF0058 R87NBF007...