Clean the chimney connector disconnecting the sections, taking them outside, and remov-

ing any deposits with a stiff wire brush. Reinstall the connetor sections after cleaning, being 

sure to secure the joints between individual sections with sheet metal screws.

If you cannot inspect or clean the chimney yourself, contact your local Morsø Dealer or a 

professional chimney sweep.

If you do experience a chimney fire, act promptly and:

1.  Close the air control.

2.  Get everyone out of the house.

3.  Call the Fire Department. 

Annual maintenance

Before the heating season, perform a thorough cleaning, inspection and repair:

Thoroughly clean the chimney and chimney connector.

Inspect the chimney for damage and deterioration. Replace weak sections of prefabricated 

chimney. Have a mason make repairs to a masonry chimney.

Inspect the chimney connector and replace any damaged sections.

Check gasketing for wear or compression, and replace if necessary.

Check the glass for cracking; replace if needed.

Check door and handles for tightness. Adjust if needed.

3.4 Leaving the stove for extended periods

Important:

If the stove is to be left unused for any period of time, clean it out thoroughly and leave the 

air control slightly open to allow airflow. Make sure that the flue does not allow rainwater to 

come anywhere near the stove; install a chimney cap, but do not block off the flue completely.

These measures should ensure there is a slight movement of air through the stove, and that 

the body of the stove remains dry, right into the corners. 

Any ash left within an unfired stove can attract moisture like blotting paper. If moisture is al-

lowed to settle within the stove, rust will form. Rust expands as it takes a grip. This can lead 

to undue pressure on the stove joints, and this in turn may result in damage to the stove.

NOTE: It is best to thoroughly clean the stove after the heating season has concluded. 

Adding a dessicant, such as kitter litter, into the ash pan helps absorb moisture during 

the summer months. Be sure to remove this prior to the heating season.

Thank you for buying a Morsø stove. 

We hope you have many years of carefree warmth in its company. Some initial experimen-

tation with loading and running techniques will decide your normal routine. If you have any 

problems after this short learning phase, please refer to your stove dealer. Should they be 

unable to help for any reason, please contact us in writing at the address on the front of 

this publication.

Содержание 2110

Страница 1: ...MORSØ JERNSTØBERI A S DK 7900 NYKØBING MORS E Mail stoves morsoe com Website www morsoe com Installation and Operating Instructions Morsø 2110 For use in North America ...

Страница 2: ...ratulations on the purchase of your new Morsø stove Morsø which is the largest supplier for the Dan ish market has manufactured stoves of the highest quality since1853 By following the instructions over leaf we are sure that you will enjoy the use and the benefits of your stove for many years to come Read this entire manual before you install and use your new room heater If this room heater is not...

Страница 3: ...y 1 1990 The Morsø 2110 are listed by OMNI Test Laboratories Inc The test standards are ANSI UL 1482 for the United States and ULC S627 for Canada The stove is listed for burning wood only Do not burn other fuels Under specific test conditions this heater has been shown to deliver heat at rates ranging from 8 600 to 42 100 Btu s Cast iron Cast iron is a live material There are no two ovens that ar...

Страница 4: ...ss the installation with them before beginning Please ask your dealer for further information Do not connect to any air distribution duct or system Important If the installation instructions are not followed carefully it may cause dan gerous situations like chimney and house fires Follow the instructions carefully and do not deviate from them as it may cause injuries to people or property 1 1 Unpa...

Страница 5: ...ctor and chimney must not be less than 6 inch es diameter or equivalent cross section and should not be significantly larger than this Too large a section will tend to allow the flue gases to cool excessively causing sluggishness or unpredictability in the stove s performance We recommend the length of the chimney system should be at least 16 feet not required above the stove in normal domestic si...

Страница 6: ...onnectors should be made of 24 gauge or heavier gauge steel Do not use galvanized connector it cannot withstand the high temperatures that smoke and exhaust gases can reach and may release toxic fumes under high heat The connector must be 6 inches 150mm in diameter If possible do not pass the chimney connector through a combustible wall or ceiling If passage through a combustible wall is unavoidab...

Страница 7: ...7 ...

Страница 8: ...be taken to ensure that they do not fall towards the stove in such an event When the stove is positioned near non combustible materials a gap of 4 inches or more is recommended for cleaning purposes and to ensure that heat circulates around the stove and out into the room CLEARANCE REQUIREMENTS STANDARD RESIDENTIAL INSTALLATION SINGLEWALL CONNECTOR USA CANADA A Sidewall to unit B Backwall to unit ...

Страница 9: ...ing side 19 31 27 18 485 mm 790 mm 685 mm 460 mm FLOOR PROTECTION REQUIREMENTS NON COMBUSTIBLE MATERIALS BENEATH STOVE USA CANADA A Extending distance back B Extending distance right side C Extending distance left side D Extending distance front 6 6 16 200 mm 200 mm 200 mm 450 mm Floor protector must be non combus tible material with an R value of 1 0 It must extend beneath heater and to the front...

Страница 10: ...hing the masonry around the stove protect the stove surface with an acid proof cover Fresh Air Inlet Unless there is deemed to be sufficient ambient leakage of air into the room via doorways windows and the like a dedicated fresh air inlet will be needed This inlet should have 2 square inches 1250 square mm of free air space This is particularly important where the room is well sealed or where an ...

Страница 11: ...d heat output wood fuel should contain no more than 20 moisture this can easily be checked by using the Morsø Moisture Meter part 62929900 To naturally season wood fuel stack and store it under cover in an airy location where fresh air can move through each piece Some soft woods may take as little as one good summer to sea son whereas harder woods such as oak maple and elm may require seasoning up...

Страница 12: ...Lighting and loading intervals When first lighting the stove a large volume of air is needed When the stove is cold you should leave the door open an inch or two for the first few minutes and open the primary air supply completely While the door is open do not leave the stove unattended To form a reasonable bed of ash on the floor of the stove you should use 5 6 inches thickness 2 4 pound of dry k...

Страница 13: ...n per manent damage to the stove If any part of the stove glows you are overfiring 5 When ready to reload use a poker to spread the ember across the firebox floor bringing plenty towards the front of the stove 6 Lay three pieces of wood see dimensions above onto the embers Leave half an inch 1 cm or more between each piece When using 10 inches 25 cm logs place the ends of your logs towards the ope...

Страница 14: ...vethestove stopplateandmeasuresthesurfacetemperature of the stove pipe Please see your authorized Morsø Dealer for availability Draft conditions If smoke or fumes come out of your stove when lightning up and reloading or if the fire simply will not respond a poor draft is almost certainly to blame In a very few cases there may be insufficient fresh air getting into the room see installation advice...

Страница 15: ...ing most will burn off as temperatures increase For heavier deposits that will not burn off use Morsø glass cleaner applied when the glass is cold in accordance with the instructions Never use abrasive cleaners on the glass surface Reasons for dirty glass Fuel too wet Logs too large or not split Combustion temperatures too low Replace broken glass immediately Do not operate your stove if the glass...

Страница 16: ...not over tighten the bolts as this may put exces sive pressure on the glass resulting in cracking important To reduce the risk of breaking the glass avoid striking the glass or slamming the door Internal service parts The flame path equipment consisting of the ashpan grate firebricks glass baffle and flue collar are subject to the extremes of heat produced by the fire From time to time one or othe...

Страница 17: ...f ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally disperded they should be retained in the closed container until all cinders have thoroughly cooled Return the ash pan to its original position in the stove and close Caution Never empty a stove in ope...

Страница 18: ...or any period of time clean it out thoroughly and leave the air control slightly open to allow airflow Make sure that the flue does not allow rainwater to come anywhere near the stove install a chimney cap but do not block off the flue completely These measures should ensure there is a slight movement of air through the stove and that the body of the stove remains dry right into the corners Any as...

Страница 19: ...19 3 5 Parts diagram for model Morsø 2110 ...

Страница 20: ...082 21 Distance tube 541440 22 Hinge pin 541808 23 Ash tray 54181500 24 Distance bush 54181700 25 Radiant shielding bottom 541820 26 Convection rear plate 54182421 27 Intermediate frame fitting 541831 28 Hinge pin 542056 29 Draught control 71180200 30 Draught control arm 71180300 31 Draught control frame 71180400 32 Baffle plate stainless 71181161 33 Black steel set screw 34 Black steel set screw ...

Страница 21: ... Pos No Parts 54 Glass fitting 54181361 55 Air slider washer 56 Screw 57 Screw 58 Plate for intermediate frame 71181261 59 Screw 60 Hanging for handle 54185800 61 Insulation 79074700 63 Door handle 54186100 65 Black steel set screw 66 Screw ...

Страница 22: ...22 G ...

Страница 23: ...oduction process and detailed measures have been put into place at all key stages of the build Accordingly provided that the stove has been supplied by an authorised Morsø dealer Morsø will offer a 10 Year Manufacturers Guarantee against manufacturing defect to any of the main exterior body parts of its stoves Read more about Morsø 10 years guarantee product registration card and REGISTER your new...

Страница 24: ...Light with dry kindling use 1 2 kg Leave the door ajar and stay close to the stove during the lighting phase Good layer of embers Be certain to have a good layer of em bers before refilling The wood should light within 2 minutes If the logs do not ignite it may in an extreme case cause the flue gases to ignite which may pose a risk to material damage or personal injury Refuelling When refuelling u...

Отзывы: