background image

The Specialist In Drum Handling Equipment

Model 400AM-96-124

Hydra-Lift, 96”, with Spark Resistant Parts, 

Air Power Lift, Manual Tilt

Operator’s Manual for Morse Hydra-Lift Karrier Model 400AM-96-124

with Serial Number 1210 to ____ (MMYY)

morsedrum.com

Copyright 2022 - Morse Mfg. Co., Inc. 

 

Form OM400AM-96-124 (1210-____)  

(Updated 3 Mar., 2022)

 

2

Safety Information (continued)

DANGER

 - Indicates a situation which, if not avoided, 

will

 result 

in serious injury or death.  This signal word is limited to the most 

extreme situations.

WARNING

 - Indicates a situation which, if not avoided, 

could

 result 

in serious injury or death.

CAUTION

 

- Indicates a situation which, if not avoided, can result in 

damage to the machine.

CAUTION

 

– Do Not Transport with Drum Raised

ALWAYS LOWER THE DRUM HOLDER TO LOWEST POSITION BEFORE TRANSPORTING. 

 The 

unit can become unstable when transporting with a raised load.

DANGER

 - Stay Clear of Power Lines

KEEP WELL CLEAR OF POWER LINES. 

 Never approach a power line.  Current in a high voltage line 

may arc some distance from the wire to the steel framed, grounded machine.

WARNING

The Hydra-Lift Karrier is designed to handle one drum of the types listed at the top of page 3, under 

2.  

Machine Description

.  

DO NOT

 attempt to handle any other type of drum or object.  

DO NOT

 exceed 

the weight capacity of 800 Lb. (363 kg).

WARNING

 

- Level Floors Only

For operation only on clean, level floors of suitable bearing capacity. Do not use on sloped surfaces, 

ramps, irregular or debris strewn floors.

WARNING

 - Do Not Modify the Unit

Under no circumstances should any modifications be made to the Morse machinery without factory 

authorization.  Any modifications may void the warranty.  This machine was designed to perform a 

specific job and alterations may result in injury to operator or machine.

WARNING

 - No Loose Fitting Clothing

Wear close-fitting clothing and safety equipment appropriate to the job.  Loose fitting clothing may 

become caught on the machinery and cause severe personal injury.

WARNING

 - Hydraulic Fluid Under Pressure Can Be Hazardous

Escaping hydraulic fluid under pressure can penetrate the skin, causing serious injury.  Avoid the 

hazard by relieving pressure before disconnecting hydraulic lines.  Keep hands and body away from 

pinholes and nozzles, which eject fluid under high pressure.  Use a piece of cardboard to search for 

leaks. If an accident occurs, see a doctor immediately and inform them of the nature of the accident.

CAUTION

 - Wear Safety Shoes - 

Wear safety shoes with non-slip soles and hard toe protection.

WARNING: 

This product can expose you to chemicals including barium sulfate, cobalt, titanium 

dioxide, and 2-methylimidazole, which are known to the State of California to cause cancer, and 

bisphenol-A, which is known to the State of California to cause birth defects or other reproductive harm. 

For more information go to 

www.P65Warnings.ca.gov

Содержание 400AM-96-124

Страница 1: ...ht always sign noting the damage on the BILL OF LADING Document the damage and have the truck driver sign We recommend keeping a digital camera at your receiving dock for this purpose Open packages expeditiously to check the condition of the goods There is only a 24 hour window to notify the carrier of any concealed damage IMMEDIATELY REPORT ALL DAMAGE TO THE SHIPPING COMPANY Then you may contact ...

Страница 2: ... Floors Only For operation only on clean level floors of suitable bearing capacity Do not use on sloped surfaces ramps irregular or debris strewn floors WARNING Do Not Modify the Unit Under no circumstances should any modifications be made to the Morse machinery without factory authorization Any modifications may void the warranty This machine was designed to perform a specific job and alterations...

Страница 3: ...t drum handler 55 30M Series Spark Resistant Diameter Adapters for drum with diameter smaller than 22 56 cm To handle a smaller drum insert the correct size Diameter Adapter into the standard drum holder See Diameter Adapter info at https morsedrum com products diameter adapters ONLY Diameter Adapters for drum with 17 5 44 5 cm diameter or smaller have integrated brackets to prevent drum slipping ...

Страница 4: ...um around it s middle using a cinch chain and ratchet tightening system It automatically adjusts for 22 to 23 5 56 to 59 7 cm diameter drum The MORCINCHTM Drum Holder also accepts accessories to handle a plastic drum fiber drum or a smaller diameter drum Controls The Morse Hydra Lift Karrier is manually propelled and steered The drum lift is powered by an air motor with an on off valve There are t...

Страница 5: ...n Release the cinch chain from the ratchet by applying pressure to the ratchet handle in a clockwise direction with one hand and opening the pawl to free the ratchet with the other hand Remove the cinch chain link from the ratchet Operating Instructions 1 Push Hydra Lift Karrier to the drum 2 Using LIFT control as described in Machine Description Controls position drum holder assembly with back ba...

Страница 6: ...ure and maintain proper function Inspect the hydraulic system for oil drips hose damage or other signs of wear Inspect the level and condition of the hydraulic fluid Replace any parts that show signs of wear Grease wheel bearings periodically Oil or grease all moving parts including the three clevis pins and the surfaces of the boom which contact the inside of the mast cap the hinge pin the gears ...

Отзывы: