The Specialist In Drum Handling Equipment
Model 400A-72SS-114
Stainless Steel Hydra-Lift, 72”,
with Air Power Lift & Tilt
Operator’s Manual for Morse Stainelss Steel Hydra-Lift Karrier
Model 400A-72SS-114, Serial Number 0614 to ____ (MMYY)
morsedrum.com
Copyright 2022 - Morse Mfg. Co., Inc.
Form OM400A-72SS-114 (0614-____) (Updated 3 Mar., 2022)
4
Figure 3.1
WARNING
- Watch Out for Pinch Points
Stay clear of moving parts. Operator should
remain behind the push handle during the
lift operation.
Floor Lock
The step-down floor lock is located behind the base (figure
3.1). To activate, step down on the floor lock until it locks
in down position. When floor lock is activated it prevents
unwanted free wheeling of unit. Floor conditions determine
effectiveness of floor lock. Operator should verify its holding
action before depending on it to hold.
Drum Holder Assembly
The MORCINCH
TM
Drum Holder (Saddle) assembly is the
component on intended to hold the drum. It is designed to secure
a standard ribbed 55-gallon (210 liter) steel drum around it’s middle
using a cinch chain and ratchet tightening system. It automatically
adjusts for 22” to 23.5” (56 to 59.7 cm) diameter drum.
The MORCINCH
TM
Drum Holder also accepts accessories to
handle a plastic drum, fiber drum, or a smaller diameter drum.
Figure 2.3
Controls
The Morse Hydra-Lift Karrier is manually propelled and steered.
The hydraulic pump is powered by a vane type air motor. The air motor is control
by a momentary air valve located on the air motor. Attach air supply to the air
valve.
There are two functions for the operator to control (Figure 2.3):
1. LIFT and lower function for vertical positioning of the drum.
•
To raise the drum, hold the air valve handle in the on position and raise the
LIFT handle. Release the two valve handles when desired drum height is
reached.
•
To lower the drum, push in the LOWER handle. Air motor is not needed.
2. TILT function to control the degree of rotation of the drum.
•
To tilt the drum forward for pouring, hold the air valve handle in the on
position and raise the TILT handle. Release the two valve handles when
drum angle is reached.
•
To return the drum to vertical position, hold the air valve handle in the on
position and push down on the TILT handle.