morse 310-1-50-CE Скачать руководство пользователя страница 6

The Specialist In Drum Handling Equipment

Model 310-1-50-CE & 310-3-50-CE

CE Marked Tilt-To-Load Drum Rotators

operator’s Manual for Morse 310-CE series CE Marked Tilt-To-Load Drum Rotators

serial number 278575 and up

morsedrum.com

Copyright 2019 - Morse Mfg. Co., Inc. 

Form PL310-CE (278575-309424) 

(Updated 16 Oct, 2020)

        

6

Base Assembly

(not sold separately)

Tilt Assembly

(not sold separately)

Drum Holder (saddle) Assembly

Part # 5801-P

Mast Assembly

Part # 5762-P

with Controls

Unloading a Drum

Ensure the drum is in vertical upright position to unload.

1. 

Squeeze the ratchet release lever and open all the way to unlock, then release the tension on the strap. Allow enough slack in the 

2. 

strap in order to remove strap loop from clevis.

Loosen top clamps and swing clear of drum.

3. 

Remove drum with appropriate drum handling equipment.

4. 

Maintenance

Periodic inspection for the general condition of structural and mechanical components is imperative for safe and efficient operation.

Inspect the hydraulic system for oil drips, hose damage, or other signs of wear. Inspect the level and condition of the hydraulic fluid. 

1. 

Hydraulic fluid level should be within a ½” of the top of the reservoir when the cylinder is in the relaxed position. Replace any parts that 

show signs of wear.

Lubricate all moving parts including: bearings, clevis pins, and threaded rod.

2. 

Periodically inspect all moving parts, framework, ratchet, straps, fasteners and contact areas for signs of wear, fatigue, or loosening. 

3. 

The web strap should be removed from service & replaced if any of the following are visible:

• 

Acid or caustic burns 

• 

Melting or charring of any part of the strap 

• 

Holes, tears, cuts, snags or embedded articles 

• 

Broken or worn stitching in load bearing splices 

• 

Excessive abrasive wear

Содержание 310-1-50-CE

Страница 1: ...um handling equipment is guaranteed against defects in workmanship or materials for two years when used properly within its rated capacity Warranty does not cover wear from normal use or damage from accident or abuse Motors and other purchased parts carry the warranties of their manufacturers For warranty claims contact your Morse Dealer to obtain a return authorization number and for return freig...

Страница 2: ...he weight capacity of 363 kg 800 Lb WARNING Level Floors Only For operation only on clean level floors of suitable bearing capacity Do not use on sloped surfaces ramps irregular or debris strewn floors WARNING Properly Mount to Floor Do Not put into service without proper floor mounting and leveling Use the four mounting holes in each corner of the base to anchor to floor WARNING Do Not Modify the...

Страница 3: ...is controlled separately by levers mounted on the control station shown right The TILT function for vertical 1 positioning of the drum holder The lever on the right side is the TILT control valve Raising the lever causes the drum holder to rise Lowering the lever will lower the drum holder The ROLL function or the 2 rotation of the drum holder The lever on the left side is the ROLL control valve R...

Страница 4: ... BEFORE operation CE Marked Tilt To Load Rotators are shipped filled with hydraulic fluid Dexron 3 or equivalent Control Station Making Connections Figure 1 310 CE Lifting Point Important When loading unloading operating or maintaining your MORSE drum handler always use care and good judgment Maintain secure footing and a firm hold Keep hands and loose clothing away from all moving parts Never all...

Страница 5: ...erfere with the floor and frame causing severe damage to equipment and or serious injury or death Loading a Drum With the drum holder in the lowered position the bottom 1 loading plate will be slightly above the floor Swing the hinged ratchet plate clear of the drum opening Loosen the top clamps to the full open position A variety of drum handling methods can be used to set the 2 drum into the dru...

Страница 6: ... drum with appropriate drum handling equipment 4 Maintenance Periodic inspection for the general condition of structural and mechanical components is imperative for safe and efficient operation Inspect the hydraulic system for oil drips hose damage or other signs of wear Inspect the level and condition of the hydraulic fluid 1 Hydraulic fluid level should be within a of the top of the reservoir wh...

Страница 7: ...0 3 50 CE CE Marked Tilt To Load Drum Rotators Operator s Manual for Morse 310 CE Series CE Marked Tilt To Load Drum Rotators Serial Number 278575 and up morsedrum com Copyright 2019 Morse Mfg Co Inc Form PL310 CE 278575 309424 Updated 16 Oct 2020 7 Base Assembly ...

Страница 8: ...Co Inc Form PL310 CE 278575 309424 Updated 16 Oct 2020 8 Cylinder Assembly ITEM QTY PART DESCRIPTION 1 1 4576B P BODY VALVE 310 2 1 4594 P HYD FIT SAE STRAIGHT SWIVEL 3 1 4593 P HYD FIT SAE STRAIGHT 4 1 4576C P CART PO CHECK 310 5 1 4572 P CYLINDER 2 X 10 5 310 6 1 3275 P CLEVIS PIN 3 3 8 310 DEAD 7 1 3276 P CLEVIS PIN 2 7 8 310 LIVE 8 2 64 P ROLL PIN 3 16 X 1 1 4 9 1 3612 P HYD FIT SAE ADAPTER 10...

Страница 9: ...P SAFETY LIMIT VALVE 310 2 1 4922 P LINK SAFETY LIMIT VALVE 310 3 1 4250 P NUT 1 4 28 NYLON LOCK 4 1 4249 P COTTER PIN 1 4 X 2 1 2 5 3 3923 P NUT 1 4 20 WHIZ LOCK 6 1 1641 P HHCS 1 4 20 X 1 GR2 7 2 4860 P FIT ADAPTOR SAE 310 8 1 1108 P HYD FIT PIPE NIPPLE 1 4 ITEM QTY PART DESCRIPTION 9 1 4027 P CHECK VALVE 310 10 1 3757 P HYD FIT SAE ELBOW 456 CYL 11 1 1107 P HYD FIT PUSH LOK 1 4 X 3 8 12 2 4923 ...

Страница 10: ...NDLE MONARCH 4 2 M01326 P ROD 4 L VALVE HANDLE MON 5 2 765 P HYD FIT MALE ELBOW FLARE 400 6 2 1105 P HYD FIT RUN TEE 456 310 7 1 2119 P HYD FIT MALE PIPE ELBOW 456 8 1 3209 P HYD FIT PIPE ADAPTER 1 4 1 8 9 2 345 P HYD FIT MALE FLARE 456 82 10 1 3301 P HYD FIT STREET ELBOW 3 8 310 Item 16 Control Box MODEL PART DESCRIPTION 310 1 50 CE 5949 P CONTROL BOX 1PH 230V TIMER CE 310 3 50 CE 5538 P CONTROL ...

Страница 11: ...10 2 1 4008 P HYD FIT PIPE REDUCER 3 4 1 4 3 2 2118 P HYD FIT STREET ELBOW 1 4 4 3 1105 P HYD FIT RUN TEE 456 310 5 3 1107 P HYD FIT PUSH LOK 1 4 X 3 8 6 1 345 P HYD FIT MALE FLARE 456 82 7 1 3299 P HYD FIT PIPE REDUCER 3 8 1 4 8 1 1108 P HYD FIT PIPE NIPPLE 1 4 Recommended spare parts Includes items 2 3 4 and 5 on page 10 Item 12 Motor MODEL PART DESCRIPTION 310 1 50 CE 3186 1 50 P MOTOR 2HP 1PH ...

Страница 12: ...E Marked Tilt To Load Drum Rotators Operator s Manual for Morse 310 CE Series CE Marked Tilt To Load Drum Rotators Serial Number 278575 and up morsedrum com Copyright 2019 Morse Mfg Co Inc Form PL310 CE 278575 309424 Updated 16 Oct 2020 12 Tilt Assembly SEE DETAIL ON PAGE 15 ...

Страница 13: ...Inc Form PL310 CE 278575 309424 Updated 16 Oct 2020 13 Hydraulic Motor Assembly ITEM QTY PART DESCRIPTION 1 1 3114 P MOTOR HYDRAULIC HYD 310 2 1 4600 P CART COUNTER BALANCE 310 3 1 4576B P BODY VALVE 310 4 1 4599 P HYD FIT NIPPLE 5 1 4598 P HYD FIT REDUCER 6 1 4597 P HYD FIT SAE TEE 7 1 3154 P HYD FIT MALE ADAPTOR SAE 310 8 1 1107 P HYD FIT PUSH LOK 1 4 X 3 8 9 1 3757 P HYD FIT SAE ELBOW 456 CYL 1...

Страница 14: ...0 CE 310 3 50 CE CE Marked Tilt To Load Drum Rotators Operator s Manual for Morse 310 CE Series CE Marked Tilt To Load Drum Rotators Serial Number 278575 and up morsedrum com Copyright 2019 Morse Mfg Co Inc Form PL310 CE 278575 309424 Updated 16 Oct 2020 14 ...

Страница 15: ...0 CE 310 3 50 CE CE Marked Tilt To Load Drum Rotators Operator s Manual for Morse 310 CE Series CE Marked Tilt To Load Drum Rotators Serial Number 278575 and up morsedrum com Copyright 2019 Morse Mfg Co Inc Form PL310 CE 278575 309424 Updated 16 Oct 2020 15 ...

Страница 16: ... to 23 5 45 72 cm to 59 69 cm 29 to 37 73 66 cm to 93 98 cm Drum RPM 4 to 16 Variable Speed Machine Height Loading Position Tumbling Position 49 75 126 37 cm 55 139 70 cm Machine Floor Space Loading Position Tumbling Position 61 Long x 39 Wide 154 94 cm x 99 06 cm 68 Long x 39 Wide 154 94 cm x 99 06 cm Enclosure Height 63 25 160 66 cm Enclosure Floor Space 88 Long x 52 Wide 223 52 cm x 132 08 cm S...

Страница 17: ...ssions EN 55011 Class A Generic Immunity Standard EN 61000 6 2 2005 Immunity EN 61000 4 2 Electrostatic Discharge EN 61000 4 6 Conducted Susceptibility Low Voltage Directive 2014 35 EU Standard EN 60204 1 Safety of Machinery Machinery Directive 2006 42 EC Standard EN 60204 Safety of Machinery Manufacturer s Name MORSE Mfg Co Inc Manufacturer s Address 103 Kuhn Rd Syracuse NY 13208 Product Tilt to ...

Отзывы: