morse 278575 Скачать руководство пользователя страница 2

The Specialist In Drum Handling Equipment

Model 456-1-50-CE & 456-3-50-CE

CE-Marked Hydra-Lift Drum Rollers

operator’s Manual for Morse 456-CE series CE-Marked Hydra-Lift Drum Rollers

serial number 278575 to ______

morsedrum.com

Copyright 2019  -  Morse Mfg. Co., Inc. 

 

Form PL456-CE (278575-______) 

(Updated 17 Oct, 2019)

        

2

safety Information

 (continued)

DAnGER 

- Indicates a situation which, if not avoided, will result in serious injury or death.  

This signal word is limited to the most extreme situations.

WARnInG 

- Indicates a situation which, if not avoided, could result in serious injury or 

death.

CAUtIon 

- Indicates a situation which, if not avoided, can result in damage to the machine.

DAnGER 

- Watch Out for Pinch Points. Stay clear of moving parts. Do Not Stand Near any Part of a Rotating Drum 

or Drum Holder. Operator should remain directly in front of the control station while operating the rotator. Morse CE-

Marked Drum Rotators comply with OSHA subpart O, 1910.212 - “General requirements for all machines.” “Revolving 

drums, barrels, and containers shall be guarded by an enclosure which is interlocked with the drive mechanism, so that 

the barrel, drum, or container cannot revolve unless the guard enclosure is in place.” (A safety enclosure is included 

with each CE-Marked MORSE drum rotator.)

WARnInG 

- The 456-CE Series is designed to handle one drum of the types listed at the top of page 3 under machine 

description. DO NOT attempt to handle any other type of drum or object.  DO NOT exceed the weight capacity.

WARnInG 

- Level Floors Only. For operation only on clean, level floors of suitable bearing capacity. Do not use on 

sloped surfaces, ramps, irregular or debris strewn floors.

WARnInG 

- Properly Mount to Floor. Do Not put into service without proper floor mounting and leveling.  Use the four 

mounting holes in each corner of the base to anchor to floor.

WARnInG 

- Do Not Modify the Unit. Under no circumstances should any modifications be made to the Morse 

machinery without factory authorization.  Any modifications may void the warranty.  This machine was designed to 

perform a specific job and alterations may result in injury to operator or machine.

WARnInG 

- No Loose Fitting Clothing. Wear close-fitting clothing and safety equipment appropriate to the job.  Loose 

fitting clothing may become caught on the machinery and cause severe personal injury.

WARnInG 

- Hydraulic Fluid Under Pressure Can Be Hazardous. Escaping hydraulic fluid under pressure can penetrate 

the skin, causing serious injury.  Avoid the hazard by relieving pressure before disconnecting hydraulic lines.  Keep 

hands and body away from pinholes and nozzles which eject fluid under high pressure.  Use a piece of cardboard to 

search for leaks. If an accident occurs, see a doctor immediately and inform them of the nature of the accident.

CAUtIon 

- Wear safety shoes with non-slip soles and hard toe protection.

CAUtIon:  

DO NOT allow drum to impact on floor.

WARnInG: 

This product can expose you to chemicals including barium sulfate, cobalt, titanium dioxide, and 

2-methylimidazole, which are known to the State of California to cause cancer, and bisphenol-A, which is known to 

the State of California to cause birth defects or other reproductive harm.  

For more information go to 

www.P65Warnings.ca.gov

Содержание 278575

Страница 1: ...imited 2 Year Warranty Morse drum handling equipment is guaranteed against defects in workmanship or materials for two years when used properly within its rated capacity Warranty does not cover wear f...

Страница 2: ...y For operation only on clean level floors of suitable bearing capacity Do not use on sloped surfaces ramps irregular or debris strewn floors WARNING Properly Mount to Floor Do Not put into service wi...

Страница 3: ...by levers mounted on the control station The TILT function for vertical 1 positioning of the drum holder The lever on the right side is the TILT control valve Raising the lever will tilt the drum to v...

Страница 4: ...the supplied BLACK breather and install hydraulic levers BEFORE operation The base has four 1 2 1 27 cm diameter holes spaced 20 3 8 wide x 62 5 8 long 51 75 cm wide x 159 07 cm long Morse recommends...

Страница 5: ...al Number 278575 to ______ morsedrum com Copyright 2019 Morse Mfg Co Inc Form PL456 CE 278575 ______ Updated 17 Oct 2019 5 Loading a Drum 1 Raise the TILT lever to tilt the load plate to floor level 2...

Страница 6: ...hook drum lifter Maintenance Periodic inspection for the general condition of structural and mechanical components is imperative for safe and efficient operation Idler wheels and drive bearings are eq...

Страница 7: ...50 CE 456 3 50 CE CE Marked Hydra Lift Drum Rollers Operator s Manual for Morse 456 CE Series CE Marked Hydra Lift Drum Rollers Serial Number 278575 to ______ morsedrum com Copyright 2019 Morse Mfg Co...

Страница 8: ...6 WHEEL 8 3 297 P BEARING 1 PILLOW BLOCK 9 6 535 P HHCS 3 8 16 X 1 1 4 GR5 10 6 1166 P WASHER 3 8 USS 1 OD 11 6 1169 P NUT 3 8 16 REV HEX LOCK 12 1 299 P DRIVE SHAFT 1 X 40 5154 13 1 736 P KEY WOODRUF...

Страница 9: ...rse 456 CE Series CE Marked Hydra Lift Drum Rollers Serial Number 278575 to ______ morsedrum com Copyright 2019 Morse Mfg Co Inc Form PL456 CE 278575 ______ Updated 17 Oct 2019 9 ITEM DRUM ROLLER MODE...

Страница 10: ...0 CE 456 3 50 CE CE Marked Hydra Lift Drum Rollers Operator s Manual for Morse 456 CE Series CE Marked Hydra Lift Drum Rollers Serial Number 278575 to ______ morsedrum com Copyright 2019 Morse Mfg Co...

Страница 11: ...456 CE Series CE Marked Hydra Lift Drum Rollers Serial Number 278575 to ______ morsedrum com Copyright 2019 Morse Mfg Co Inc Form PL456 CE 278575 ______ Updated 17 Oct 2019 11 ITEM 2 MOTOR ITEM DRUM R...

Страница 12: ...to 26 15 24 cm to 66 04 cm up to 40 tall 101 60 cm Drum RPM 4 to 16 Variable Speed Machine Height Loading Position Rolling Position 60 152 40 cm 35 88 90 cm Machine Floor Space Loading Position Rolli...

Страница 13: ...EN 55011 Class A Generic Immunity Standard EN 61000 6 2 2005 Immunity EN 61000 4 2 Electrostatic Discharge EN 61000 4 6 Conducted Susceptibility Low Voltage Directive 2014 35 EU Standard EN 60204 1 S...

Отзывы: