Instructions
Installation Instructions
To install tub
1.
-S models
:
a. Connect tub drain to installed drain line using supplied 51 mm (2 inch) drain
tube coupling and escutcheon and position the tub in desired location.
b. Trace outline of skirt on floor near the four holes (for all but slant back) or six
holes (for slant back) in the base of the skirt.
c. Mark location of holes directly below them on floor.
d. Disconnect drain tube coupling and move tub aside. Depending on the
model, 2 people may be required to move the tub.
e. Measure 19 mm (3/4 inch) inward (for all but slant back) or 32 mm (1-1/4
inch) inward (for slant back) from the lines marked in step b at the hole
locations marked in step c.
f. Remove and set aside attaching hardware from mounting clip assemblies.
g. Attach brackets to floor using 6.35 mm (1/4 inch) bolts, aligning the brackets
so they are just inward from and parallel to the line drawn in step b to allow
for the sheet metal thickness of the tub skirt.
h. Lift the tub over the brackets and attach with the bolts and washers using a
Phillips screwdriver.
i. Attach filler inlet assembly.
2.
-SP models
:
a. Connect tub drain to installed drain line using supplied 51 mm (2 inches)
outer diameter drain tube coupling and escutcheon and position tub in
desired location, keeping at least 30.5 cm (12 inches) clearance around
outside of tub (see Figure 1).
b. Mark bolt hole locations in post onto floor.
c. Set tub aside and install 9.53 mm (3/8 inches) anchors in floor.
d. Re-connect tub drain to installed drain line and tighten connections.
e. Attach filler inlet assembly.
To install thermometer
, insert sensing rod (7) through upper bracket
(8) and into lower bracket (9), then tighten screw (10).
Figure 2: Installing thermometer