Morris MOR-PAC90WIFI Скачать руководство пользователя страница 6

                              2. FOR YOUR SAFETY 

Your safety is the most important thing we are concerned 

about! 

2.1    OPERATIONAL PRECAUTIONS 

WARNING- to reduce the risk of fire, electric shock or injury to 
persons or property​: 

 

 

WARNING

 

Please read this manual carefully and fully 
understand before operating your appliance. 

If the supply cord is damaged, it must be replaced by the 
manufacturer, its service agent or similarly qualified persons in order 

to avoid a hazard. 

The appliance shall be disconnected from its power source during 

service. 

Always operate the unit from a power source of equal voltage, 
frequency and rating as indicated on the product identification plate. 

Always use a power outlet that is grounded. 

Unplug the power cord when cleaning or when not in use. 

Do not operate with wet hands. Prevent water from spilling onto the 

unit. 

Do not immerse or expose the unit to rain, moisture or any other 

liquid. 

Do not leave the unit running unattended. Do not tilt or turn over the 
unit. 

Do not unplug while the unit is operating. 

Содержание MOR-PAC90WIFI

Страница 1: ...Portable Air Conditioner Owner s Manual Original instructions MOR PAC90WIFI With R290 refrigerant READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...CONTENTS 1 BEFORE YOU BEGIN 2 FOR YOUR SAFETY 3 PRODUCT OVERVIEW 4 INSTALLATION 5 OPERATION 6 CLEANING AND CARE 7 TROUBLESHOOTING 8 DECOMMISSIONING 2...

Страница 3: ...s where installation of an Air conditioner with an Outdoor Unit is limited The environmentally friendly R290 is used as the refrigerant R290 has no damaging influence on the ozone layer ODP a negligib...

Страница 4: ...and user maintenance shall not be made by children without supervision The unit is designed only for use with R 290 propane gas as the designated refrigerant The refrigerant loop is sealed Only a qua...

Страница 5: ...until the qualified service technician has arrived and that technician advises that it is safe to return to the room No open flames cigarettes or other possible sources of ignition should be used ins...

Страница 6: ...d persons in order to avoid a hazard The appliance shall be disconnected from its power source during service Always operate the unit from a power source of equal voltage frequency and rating as indic...

Страница 7: ...e installed in accordance with national wiring regulations Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer The appliance shall be sto...

Страница 8: ...or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in acco...

Страница 9: ...area shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the work space shall be sectioned off Ensure that the conditions within the a...

Страница 10: ...work A degree of ventilation shall continue during the period that the work is carried out The ventilation should safely disperse any released refrigerant and preferably expel it externally into the a...

Страница 11: ...ntil it is satisfactorily dealt with If the fault cannot be corrected immediately but it is necessary to continue operation an adequate temporary solution shall be used This shall be reported to the o...

Страница 12: ...IAGRAM Note The appearance is only for reference Please see the real product for detailed information 12 1 Control panel 4 Air inlet with air filter 6 Drainage Hole 2 Air outlet with adjustable louver...

Страница 13: ...g and display LED Digital display Electronic control with built in timer sleep mode Self evaporating system for better efficient Auto shut off when tank full Automatic restart in the event of power ou...

Страница 14: ...G Unpack the carton and take the appliance and accessories out Check the device after unpacking for any damage or scratches on it Accessories 1 Exhaust hose 2 Hose connector 3 Window kit adapter 4 Rem...

Страница 15: ...the air inlet and outlet free of obstacles Never install the unit where it could be subject to Heat sources such as radiators heat registers stoves or other products that produce heat Direct sunlight...

Страница 16: ...Do not replace or extend exhaust hose which will result in decreased efficiency even worse shut down the unit due to low back pressure Step 1 Connect the hose connector to one end of the exhaust hose...

Страница 17: ...e if required It is recommended that t he gap between the adapter and the sides of the window should be sealed off for maximum efficiency Step 5 Attach the hose connector to the exhaust air outlet of...

Страница 18: ...Step 7 Adjust the louver at the air outlet and then switch on the unit 18...

Страница 19: ...5 OPERATION 5 1 CONTROL PANEL AND DISPLAY 19...

Страница 20: ...R Press to switch the machine on or off 5 DOWN Decreasing the desired temperature or timer setting 6 SPEED Press to switch the fan speed between HIGH and LOW 7 TIMER Sets a time for the unit to automa...

Страница 21: ...5 2 REMOTE CONTROL 21...

Страница 22: ...s up Press the Up Down button to adjust the temperature which is displayed on the screen The temperature can be set between 16 and 32 Press the SPEED button repeatedly until the desired fan speed indi...

Страница 23: ...rain outlet at the bottom of the unit Note In this mode the fan speed switches over to low speed and cannot be selected C Sleep mode this function can only be used with a remote control The sleep mode...

Страница 24: ...he evaporator coil temperature is below 1 C after the compressor will stop operating for 10 minutes or the coil temperature up to 7 the unit restarts to cool operating mode B When the unit operates in...

Страница 25: ...a distance of about 5 meters to your router 4 As long as the power is turned on the WIFI indicator flashes slowly After 3 minutes the status will be canceled if there is no network configuration and...

Страница 26: ...disconnect the WIFI lamp lights off 26...

Страница 27: ...tached drain hose to the unit Condensate water can be automatically flow into a bucket or drain by gravity 27 TROUBLESHOOTING of WIFI CONNECTION Network connection failed Solution Network connection t...

Страница 28: ...ter mesh from the unit 28 Switch off the unit before operating Remove the plug of the water outlet opening and keep it in a safe area Securely and properly connect the drain hose and make sure it is n...

Страница 29: ...through the filter in the opposite direction of airflow Set aside and allow the filter to air dry completely before reinstalling 29 Pic1 Switch off the unit and remove the two air filters Pic2 Rinse...

Страница 30: ...n equipment PPE 4 Evacuate unnecessary personnel isolate and ventilate the area 5 Do not get in eyes on skin or on clothing Do not breathe vapors or gas 6 Prevent entry to sewers and public waters 7 S...

Страница 31: ...erly set Set the mode and temperature at the proper set point according to the manual refer to page16 The exhaust hose is detached Make sure the exhaust hose is securely attached Water Leakage Overflo...

Страница 32: ...32 E2 Coil temperature sensor failures Check connection or replace it To clean or replace the temperature sensor Ft Condensate water high level alarm Empty the drain pan by removing the rubber plug...

Страница 33: ...d area 4 Re install the filter at its position 5 The unit must be kept in an upright position when in storage 6 Preserving the machine in ventilating dry non corrosive gas and safe places indoors ATTE...

Страница 34: ...local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get in...